24kv 2500A60Hz Three Phases 3 Poles Dead Tank Sf6 Gas Insulating Circuit Breaker

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of US$ 30000/Piece
Request Sample
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500 RMB
Plant Area
1001~2000 square meters
  • 24kv 2500A60Hz Three Phases 3 Poles Dead Tank Sf6 Gas Insulating Circuit Breaker
  • 24kv 2500A60Hz Three Phases 3 Poles Dead Tank Sf6 Gas Insulating Circuit Breaker
  • 24kv 2500A60Hz Three Phases 3 Poles Dead Tank Sf6 Gas Insulating Circuit Breaker
  • 24kv 2500A60Hz Three Phases 3 Poles Dead Tank Sf6 Gas Insulating Circuit Breaker
  • 24kv 2500A60Hz Three Phases 3 Poles Dead Tank Sf6 Gas Insulating Circuit Breaker
  • 24kv 2500A60Hz Three Phases 3 Poles Dead Tank Sf6 Gas Insulating Circuit Breaker
Find Similar Products

Basic Info.

Model NO.
LW24
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
SF6
Installation
Fixed
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000
Transport Package
1PC/Pk
Specification
15KV, 24KV, 33KV
Trademark
HEMG
Origin
China
Production Capacity
10000

Product Description

24kv 2500A60Hz Three Phases 3 Poles Dead Tank Sf6 Gas Insulating Circuit Breaker
S/N Specifications of CIRCUIT BREAKER 13.8 kV DEAD TANK
1 Features Order
2 Quantity 1
3 Model LW24
4 Manufacter HEMG
5 Origin CHINA
6 Installation outdoor, 1000 meters over sea level
7 Type DEAD tank
8 Class substation
9 Insulation system SF6
10 CB features  
11 Pole number 3
12 Operation type 3 phase
13 Nominal voltage  13.8 kV
14 Frequency 60 Hz
15 Max. Voltage 25 kV
16 BIL  110 kV (industry frequency)
17 200 kV (1,2x50 µs)
18 Rated current 2000A
19 Rated no load current 16 A
20 Isc 31.5kArms
21 Continuous component 32%
22 Opening factor (first pole) 1.000
23 Voltage increase  0.81 kV/µs
24 Closing rated short circuit capacity 65 kA
25 Operative cycle O-0.3s-CO-180 s-CO
26 Short circuit nominal duration 1 s
27 Rated interruption capacity with phases discordance 5 kA
28 Maximun interruption total time 50 ms
29 Maximun dead time (fast reclosing) 100 ms
30 Reclosing range setting 330 ms
31 Creepage distance 500 mm
32 Operation mechanism  
33 Nominal voltage operation 125 V dc
34 Mechanism type motor-coil
35 Mechanical endurance class M2
36 TRIPPING COILS 2
37 CLOSING COILS 1
38 Bushings  
39 Insulator material porcelain
40 CT´s bushing type  
41 CT´s NUMBER PER BUSHING AT INCOMING SIDE  2(1CT FOR MEATERING ,1 FOR PROTECION )
42 CT'S NUMBER PER BUSHING AT OUTGOING SIDE 2(1CT FOR MEATERING ,1 FOR PROTECION )
43 CURRENT RATIO 1200/5
44 Secondary winding  precision / load 60VA Cl 5P20
45 Secondary winding measurement / load 60VA Cl 0.2
46 Certificate of an international entity of prototype test reports YES
47 SPARE PARTS  
48 SEALING KITS 1SET
49 COILS  3OPENING COILS ,3 CLOSING COILS
50 AUXIALLY RELAY 1SET

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier