330kv 4000A Circuit Breaker 63 Ka

Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: SF6
Installation: Fixed
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Samples:
US$ 100000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
LW25
Certification
ISO9001-2000
Transport Package
1PC/Container
Specification
330KV
Trademark
Hyuanpower
Origin
China
Production Capacity
1000

Product Description

330kv 4000A Circuit Breaker 63 Ka
TECHNICAL DATA SCHEDULE
CIRCUIT BREAKER, 330 kV, 63 kA, 4000A
 
ITEM DESCRIPTION UNITS REQUIRED GUARANTEED
1.0 Manufacturer - SIEMENS, ABB, VATECH, AREVA or Equivalent hemg
1.1 Type - SF 6 Gas Sepárate filling pole SF6 GAS SEPARATE FILLING POLE
1.2 MAKE: - SIEMENS, ABB, VATECH, AREVA or Equivalent XD
12.1 Model        
1.3 Country of origin - USA, Germany, UK or any other European  country CHINA
2.0 Nominal characteristics      
2.1 Rated maximum voltage KV 362 362
2.2 Rated lightning impulse (BIL) KV peak 1175 1175
2.3 Rated switching withstand voltage KV RMS 950 950
2.4 Power frequency withstand voltage KV RMS 570 570
2..5 Rated frequency Hz 50 50
2.6 Rated short time withstand current KA 63 63
2.7 Rated short circuit breaking current KA 80 80
2..8 Rated short circuit making current KA peak 170 170
2.9 Number of poles - 3 3
2.10 Operation - Single  poles Single  poles
2.11 Rated current A 4000 4000
2.12 Breaking time ms £ 45 £ 45
2.13 Closing time ms £ 45 £ 45
2.14 Operating sequence - O-0,3 s -
 CO-3 min -CO
O-0,3 s -
 CO-3 min -CO
2.15 Annual rate of gas leakage
at normal pressure of
%
Bar
< 1%
6.0
< 1%
6.0
2.16 First Pole to clear factor   1.3 1.3
2.17 Creepage distance to earth and between terminals mm 7240 min.
As per pollution level of site
MIN7240
2.18 Rated TRV for faults at terminals


-       TRV crest value
-       TRV rate of rise
- Initial TRV
- Time to crest of initial TRV



kV
kV/ms
kV
msec



538
2
3,5
0,8
 
 
538
2
3,5
0,8
2.19 Rated TRV for short line faults


-       TRV crest value
-       TRV rate of rise
-       Surge impedance



kV
kV/ms
ohms



414
2
450
 
 
414
2
450
2.20 Rated out-of-phase breaking capability


-       Rated out-of-phase current
-       Power frequency recovery voltage



kA
kV
 

7,8
418
 
7,8
418
2.21 Rated TRV out-of-phase breaking


-       TRV crest value
-       TRV rate of rise



kV
kV/ms



739
1,54



739
1,54
2.22 Rated line charging breaking capability


-       rated line charging breaking current
                 (no restrike)
-       TRV crest value
-       TRV duration after breaking



A
 
kV
s



400
 
800
0,3



400
 
800
0,3
2.23 Radio Interference Voltage (RIV)
- R.I.V. max voltage level (IEC 694) at 0,5 MHz and 362 kV test voltage
 
mV
 
2500
 
2500
2.24 Capacitors across terminals pF -  
2.25 Number of operations without maintenance


-       CO at no load
-       CO at rated current
-       CO at rated breaking current



-
-
-



-
-
-
 
 
10000
3000
20
2.26 HV Terminals connectors for - TBA TBA
2.27 Site altitude   m.a.s.l  <1001 m.a.s.l  <1001