TECHNICAL DATA SHEET
FOR 15MVA, 33/11kV
DISTRIBUTION POWER TRANSFORMER
ITEM |
DESCRIPTION |
UNIT |
REQUIRED |
GAURANTEED |
1. |
Manufacturer |
HEMG |
||
2. |
Country of manufacture |
|
CHINA |
|
3. |
Type of transformer |
|
Three Phase Step Down Power Transformer |
Three Phase Step Down Power Transformer |
4. |
Standard and tolerances |
|
IEC 60076 |
IEC 60076 |
5. |
Installation |
|
Outdoor |
Outdoor |
6. |
Insulation fluid |
|
Mineral oil (type NYNAS 10 GBX) |
Mineral oil (type NYNAS 10 GBX) |
7. |
Type of preservation |
|
Conservator with air breather |
Conservator with air breather |
8. |
Type of cooling |
|
ONAN |
ONAN |
9. |
Type of core (shell type/core type) |
|
Core Type |
Core Type |
10. |
Rated power (ONAN/ONAF) |
MVA |
15 |
15 |
11. |
Rated voltages at no-load - HV side - LV side |
kV kV |
33 / 11 |
33 / 11 |
12. |
Rated frequency |
Hz |
50 |
50 |
13. |
Type of tap changer on HV side |
|
On-load (ABB type UZ) |
On-load (ABB type UZ) |
14. |
Type of regulation |
|
CFR |
CFR |
15. |
Number of taps |
|
17 (+,-8 x 1.25%) |
17 (+,-8 x 1.25%) |
16. |
Vector group |
|
YD1 |
YD1 |
17. |
Temperature rise: - Top oil - Windings - Hot spot |
K K K |
45 55 68 |
45 55 68 |
18. |
Impedance voltage |
% |
10% at 15MVA, 33/11kV base |
10% at 15MVA, 33/11kV base |
19. |
No load loss at rated voltage |
KW |
13 |
13 |
20. |
Load loss at nominal tap |
KW |
76 |
76 |
21. |
Auxiliary loss |
KW |
N/A |
N/A |
22. |
Flux density at nominal tap |
T |
<1.72 |
<1.72 |
23. |
No load current at nominal tap |
% |
0.22 |
0.22 |
24. |
Lightning Impulse test voltage - Full wave (peak) (Acc. To IEC 60076-3) - HV winding - HV Neutral - LV winding |
kVp kVp kVp |
650 - 170 |
650 - 170 |
25. |
Short-duration induced AC withstand voltage - HV - LV |
kV |
70, 22 |
70, 22 |
26. |
Separate source AC withstand voltage test, (Acc. to IEC 60076-3) - HV winding - LV winding |
kV |
38 70 |
38 70 |
27. |
Sound Pressure level (ONAN/ONAF) |
dB |
62 |
62 |
28 |
Overload/Fault current capability |
kA |
Accr. to IEC 354 |
Accr. to IEC 354 |
29. |
Basic Insulation level |
M |
LI 650 AC 170 / 75 (Phase) |
LI 650 AC 170 / 75 (Phase) |
30. |
Short Circuit Impedances: Lowest tap Highest tap |
/phase /phase |
After Placement of Order |
After Placement of Order |
31. |
Physical Dimensions |
W x L x H |
4650*3700*4000MM |
|
32. |
Total Quantity of Oil required |
kg |
8650KG |
|
33. |
Filling Medium of Tank for shipment If oil, state the quantity required |
Ltrs |
Transformer will be shipped with oil |
|
34. |
Total capacity of conservator |
Ltrs |
|
|
35. |
Total weight of Transformer |
kg |
32500KG |