• 220V/380V/440V Split Core Current Transformers
  • 220V/380V/440V Split Core Current Transformers
  • 220V/380V/440V Split Core Current Transformers
  • 220V/380V/440V Split Core Current Transformers

220V/380V/440V Split Core Current Transformers

Application: Instrument
Type: Current Transformer
Phase: Single
Operation Condition: Indoor
Usage: Protection, Measurement
Insulating Medium: Epoxy Resin
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
LMZ
Installation
Penetration Type
Transport Package
Wooden
Specification
220v/380v/440v
Trademark
HEMG
Origin
China
Production Capacity
100000

Product Description

220V/380V/440V Split Core Current Transformers
ITEM DESCRIPTION UNIT REQUIRED GUARANTEED
1  CURRENT TRANSFORMERS      
  BRAND   INDICATE HEMG
1.1 STANDARD OF MANUFACTURE AND TESTS   IEC 60044-1 IEC 60044-1
1.2 TYPE   SPLIT CORE SPLIT CORE
1.3 OPERATION VOLTAGE V 220, 380, 440 220, 380, 440
1.4 THERMAL CURRENT OF SHORT CIRCUIT   (Ith)   60 In 60 In
1.5 MAX. VOLTAGE (Um) KV 0.72 0.72
1.6 DYNAMIC CURRENT ( Idym)   2.5 Ith 2.5 Ith
1.7 RELATION OF TRANSFORMATION A 500/5 500/5
    A 400/5 400/5
    A 300/5 300/5
    A 250/5 250/5
    A 200/5 200/5
    A 150/5 150/5
    A 100/5 100/5
    A 75/5 75/5
    A 50/5 50/5
1.8 PRECISION CLASS   0.5S 0.5S
1.9 FREQUENCY HZ 60 60
1.10 INSULATION LEVEL KV 3 3
1.11 CAPACITY FOR CABLES OF 35 MM2   YES YES
1.12 CENTRAL WINDOW DIAMETER. MM 30 30
1.13 TYPE OF ASSEMBLY.   OUTDOOR OUTDOOR
1.14 ROOM TEMPERATURE.   FROM - 5 TO + 40°C FROM - 5 TO + 40°C
1.15 WORK TEMPERATURE.   +75°C +75°C
1.16 WORKING HEIGHT. MOSL 1000 1000
1.17 SEALED HERMETIC.   YES YES
1.18 EQUIPMENT MATERIAL.   RESYN RESYN
2 ACCESSORIES.      
2.1 METAL PLATE WITH CHARACTERISTICS IN LOW RELIEF (NO STICKER).   YES YES
2.2 SECONDARY BORDER WITH PROTECTION.   YES YES
2.3 SCREWS AND STAINLESS STEEL TERMINALS FOR THE ADJUSTMENT OF THE CABLE.   YES YES
2.4 IDENTIFICATION OF POLARITY IN HIGH RELIEF.   YES YES
2.5 IDENTIFICATION IN LOW RELIEF ON THE RESIN WITH THE LOGO: "ELOR", SERIAL NUMBER AND YEAR OF MANUFACTURE.   YES YES
2.6 PROTOCOL OF EVIDENCE OF EACH CT ISSUED BY RECOGNIZED ENTITY (WILL BE ATTACHED TO THE DELIVERY OF THE PRODUCTS).   YES YES
 
ITEM DESCRIPTION UNIT REQUIRED GUARANTEED
1  CURRENT TRANSFORMERS      
  BRAND   INDICATE HEMG
1.1 STANDARD OF MANUFACTURE AND TESTS   IEC 60044-1 IEC 60044-1
1.2 TYPE   SPLIT CORE SPLIT CORE
1.3 OPERATION VOLTAGE V 220, 380, 440 220, 380, 440
1.4 THERMAL CURRENT OF SHORT CIRCUIT   (Ith)   60 In 60 In
1.5 MAX. VOLTAGE (Um) KV 0.72 0.72
1.6 DYNAMIC CURRENT ( Idym)   2.5 Ith 2.5 Ith
1.7 RELATION OF TRANSFORMATION A 500/5 500/5
    A 400/5 400/5
    A 300/5 300/5
    A 250/5 250/5
    A 200/5 200/5
    A 150/5 150/5
    A 100/5 100/5
    A 75/5 75/5
    A 50/5 50/5
1.8 PRECISION CLASS   0.5S 0.5S
1.9 FREQUENCY HZ 60 60
1.10 INSULATION LEVEL KV 3 3
1.11 CAPACITY FOR CABLES OF 35 MM2   YES YES
1.12 CENTRAL WINDOW DIAMETER. MM 30 30
1.13 TYPE OF ASSEMBLY.   OUTDOOR OUTDOOR
1.14 ROOM TEMPERATURE.   FROM - 5 TO + 40°C FROM - 5 TO + 40°C
1.15 WORK TEMPERATURE.   +75°C +75°C
1.16 WORKING HEIGHT. MOSL 1000 1000
1.17 SEALED HERMETIC.   YES YES
1.18 EQUIPMENT MATERIAL.   RESYN RESYN
2 ACCESSORIES.      
2.1 METAL PLATE WITH CHARACTERISTICS IN LOW RELIEF (NO STICKER).   YES YES
2.2 SECONDARY BORDER WITH PROTECTION.   YES YES
2.3 SCREWS AND STAINLESS STEEL TERMINALS FOR THE ADJUSTMENT OF THE CABLE.   YES YES
2.4 IDENTIFICATION OF POLARITY IN HIGH RELIEF.   YES YES
2.5 IDENTIFICATION IN LOW RELIEF ON THE RESIN WITH THE LOGO: "ELOR", SERIAL NUMBER AND YEAR OF MANUFACTURE.   YES YES
2.6 PROTOCOL OF EVIDENCE OF EACH CT ISSUED BY RECOGNIZED ENTITY (WILL BE ATTACHED TO THE DELIVERY OF THE PRODUCTS).   YES YES

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now