11kv/27kv/38kv 50Hz/60Hz on Load Tap Changer for Power Automatic Transformer

Product Details
Customization: Available
Application: Power, Rectifier, Power Transformer
Phase: Three
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500 RMB
Plant Area
1001~2000 square meters
  • 11kv/27kv/38kv 50Hz/60Hz on Load Tap Changer for Power Automatic Transformer
  • 11kv/27kv/38kv 50Hz/60Hz on Load Tap Changer for Power Automatic Transformer
  • 11kv/27kv/38kv 50Hz/60Hz on Load Tap Changer for Power Automatic Transformer
  • 11kv/27kv/38kv 50Hz/60Hz on Load Tap Changer for Power Automatic Transformer
  • 11kv/27kv/38kv 50Hz/60Hz on Load Tap Changer for Power Automatic Transformer
  • 11kv/27kv/38kv 50Hz/60Hz on Load Tap Changer for Power Automatic Transformer
Find Similar Products

Basic Info.

Model NO.
SYJZZ
Certification
ISO9001
Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Specification
15KV/27KV/38KV, 50HZ/60HZ,
Trademark
HEMG
Origin
China
Production Capacity
10000

Product Description

1. General

Type SYTZZ-33/200-17 is an in-tank mounting on-load tap changer, it applies resistance transition Principle. The OLTC is a selector switch type with an oil compartment to separate OLTC oil from transformer oil . there is a motor drive mechanism in the top of OLTC and the motor is controlled by Yk-2 controller . The OLTC has the advantages of simple structure and easy maintenance.




3. Technical Specification
SYTZZ-33/200-17 is designed and produced according to IEC-60214-1(2003), the main specifications is shown by Table 1.
 
Table 1 SYTZZ-33/200-17 series OLTC Technical Specification
Model SYTZZ-33/200-17
Rated voltage(KV) 33
Rated through current(A) 200
Rated frequency(HZ) 50
Maximum through current (A) 240
Phase number 3
Wiring method End part voltage regulation
Max working position number 17
Maximum step voltage (V) 600
Insulation
Level
(KA)
Insulation grade 33
Max working voltage 36
Industrial
test voltage 1min
To earth 85
Between phase 85
Between max. and min. 36
Between neighboring contact 36
Shocking test (1.2/50us) 200
Shout circuit test Thermal stability(3S) 4
Dynamic stability 10
Mechanical life (10000 times) Not less than 50
Electrical life Not less than 5
Tight test Working pressure 3×104 Pa
Test pressure 6×104 Pa     24h without leakage
Switch weight (without oil) (kg) 130
Oil weight filled According to switch height
Drying 105+ 5ºC
Controller fitted YK-2
 

5. Operation Condition

5.1 Service ambient air temperature range of tap changer is -25ºC ~ +40ºC,Relative humidity is less then 85%.

5.2 Service temperature range of the tap changer in oil is -25ºC ~ +100ºC.

5.3 Vertical inclination of OLTC should not be over 2% when it is mounted onto the transformer.

5.4 OLTC should be operated in the place without heavy dusty and any corrosive or explosive gas.

 

 

 

6. Automatic Voltage Regulator

SYTZZ-33/200-17 OLTC is equipped with automatic voltage regulator YK-2. please refer to appendix for YK-2 automatic voltage regulator circuit diagram.

 

 

 

7. Special Design.

Special design will be provided according to the requirements of the customer. The OLTC can be equipped with temperature sensor for cold region application and a manual operation mechanism with DC power supply to YK-2 AVR for position display during installation.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier