33kv/69kv/138kv 60Hz/50Hz Outdoor Capacitor Voltage Transfroemr with Grouping Box

Product Details
Customization: Available
Application: Instrument
Type: Voltage Transformer
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500 RMB
Plant Area
1001~2000 square meters
  • 33kv/69kv/138kv 60Hz/50Hz Outdoor Capacitor Voltage Transfroemr with Grouping Box
  • 33kv/69kv/138kv 60Hz/50Hz Outdoor Capacitor Voltage Transfroemr with Grouping Box
  • 33kv/69kv/138kv 60Hz/50Hz Outdoor Capacitor Voltage Transfroemr with Grouping Box
  • 33kv/69kv/138kv 60Hz/50Hz Outdoor Capacitor Voltage Transfroemr with Grouping Box
  • 33kv/69kv/138kv 60Hz/50Hz Outdoor Capacitor Voltage Transfroemr with Grouping Box
Find Similar Products

Basic Info.

Model NO.
TYD
Operation Condition
Outdoor
Usage
Protection, Measurement
Winding Form
Multilayer Honeycomb Type
Insulating Medium
Capacitor
Installation
Busbar Type
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Capacitive Type
Transport Package
Carton with Wooden
Specification
33KV/72.5KV/123KV/132KV/145KV
Trademark
HEMG
Origin
China
Production Capacity
50000PCS

Product Description

33kv/69kv/138kv 60Hz/50Hz Outdoor Capacitor Voltage Transfroemr with Grouping Box

 
CAPACOTR Voltage Transformer 138 kV
Description Unit Value Required
 
Guaranteed
 
1.0.0 General Data      
1.1.0 Manufacturer   Indicate HEMG
1.2.0 Model   Indicate Capacitive
1.3.0 Year of fabrication   Indicate 2016
1.4.0 Country of origin   Indicate CHINA
1.5.0 Reference   Indicate IEC61869-5:2011
1.6.0 Altitude of operation msnm 2000 2000
1.7.0 Location   Forest Forest
1.8.0 Type of installation   Exterior Exterior
1.9.0 Standard of manufacture   IEC 60044-5, IEC 60358 IEC 60044-5, IEC 60358
1.10.0 Type of casing   Brown porcelain, IEC 61264 Brown porcelain, IEC 61264
1.11.0 Pollution level mm/kV 31 31
 
 
  System Parameters      
2.0.0 Operating voltage KV 138 138
2.1.0 Maximum voltage of material (Um) KV 170 170
2.2.0 Rated withstand voltage at industrial frequency (Ud) KV 325 325
2.3.0 Rated withstand voltage by lightning impulse KV 750 750
2.40 Assigned frequency (Fr) Hz 60 60
2.5.0 Assigned voltage factor      
a) Permanent   1.2 1.2
b) During 30 sec   1.5 1.5
2.6.0 Total capacity pF 12500 12500
2.7.0 High voltage capacitor (C1) pF Indicate 14937
2.8.0 Intermediate voltage capacitor (C2) pF Indicate 76625
2.9.0 Rated intermediate voltage in open circuit for HF coupling box KV Indicate 13
2.10.0 Number of secondary windings   3 (A measurement core and two for protection) 3
2.11.0 Transformation ratio   138/3 : 100/3: 100/3: 100/3 138/√3/0.1/√3/0.1/√3/0.1/√3 kV
2.12.0 Reference frequency range   Indicate 60+-1.5HZ
a) Precision class of measurement % <= 0.2 0.2
b) Precision class of protection % 5P 3P
2.13.0 Burden VA 30 30
2.14.0 Accuracy class between 25% and 100% of the precision load 0.8 power factor lag    Indicate 0.2/3P
a) between 5% and 80% of the rated voltage   5P 3P
b) between 80% and 120% of the rated voltage   <= 0.2 0.2
c) between 120% and 150% of the rate voltage   5P 3P
2.15.0 Precision load      
a) Winding 1 - measure VA 30 30
b) Winding 2 - Protection VA 30 30
c) Simultaneous VA 30 30
d) Thermal power limit VA Indicate 800
2.16.0 Rated voltage of the system      
a) Primary (Upn) KV 138/√3 138V3   
b) Secondary (Usn) V 100/√3 100V3
2.17.0 Arcing distance Mm   1860
2.18.0 Creepage distance according to IEC 60815      
a) For heavy pollution level mm/kv 31 31
2.19.0 Short-circuit current 1 sec characteristics kA 40 40
2.20.0 Dynamic current peak kA Indicate 80
 3.0..0 MECHANICAL PARAMETERS      
3.1.0 Total weight Kg Indicate 700
3.2.0 Internal insulation for capactive bodies   Synthetic oil Synthetic oil
3.3.0 Total isolation quantity in electromagnetic unit L Indicate 90
Internal insulation for electromagnetic unit   Mineral oil Mineral oil
3.4.0 Packaging used for mounting electromagnetic unit   Indicate Exporting Package
3.5.0 Diaphragm type   Indicate polypropylene film
3.6.0 Protection grade IP65 for each terminal   si YES
3.7.0 Seismic data (high condition)   Indicate 138KV/2000M
a) Natural frequency (high condition) Hz Indicate 60HZ+-1.5HZ
b) Critical damping coefficient (high condition) % Indicate 0.3
c) Horizontal acceleration g 0.5 0.5
d) Vertical acceleration g 0.2 0.2
3.8.0 Permissilbe load on terminals      
a) Static N Indicate 2000
b) Dynamic N Indicate 2000
3.9.0 Maximum allowed load by mounting pedestal-type wave trap N Indicate 30
3.10.0 Maximum allowed effort in porcelain daN/mm2 Indicate 20
3.11.0 Mean time between failure (MTBF) Days Offer value 1825
3.12.0 Mean time to repair (MTTR) Days Offer value 365
 4.0.0 ACCESSORIES FOR ASSEMBLY      
4.1.0 Grouping box secondary circuit and electrical system included   Yes YES
4.2.0 Central box of circuits for three voltage transformers   Yes YES
4.3.0 Micro switch for secondary ciruit protection (MCB)   Yes, needs to be supplied YES
a) Rated current A 6 6
b) Type curve   Z Z
c) Auxiliary contact for position indication and tripping   Yes YES
4.4.0 Protection device ferroresonance   Yes YES
4.5.0 Sampling valve for mineral oil in electromagnetic box   Gate type GATE TYPE
4.6.0 Oil gauge   Yes YES
4.7.0 Type of plate for alternative corrosive area, low relief   Anodized aluminium ALUMINIUM
4.8.0 Ground terminal   Yes YES
4.9.0 Connecting elements for communication system (carrier system)      
a) Coil drain   No No
b)Descargador   No No
c) Grounding blade high frequency signal   No No
4.10.0 Grounding blade of medium voltage to measure capacitance C1, C2   Yes Yes
4.11.0 Mounting pedestal for wave trap   No No
 
 
SPECIFIATION OF  CAPACITOR Voltage Transformer 60 kV
Description Unit Value Required
 
Guaranteed
 
1.0.0 General Data      
1.1.0 Manufacturer   Indicate HEMG
1.2.0 Model   Indicate Capacitive
1.3.0 Serial numbers   Indicate CVT2015001
1.4.0 Country of origin   Indicate CHINA
1.5.0 Reference   Indicate IEC61869-5:2011
1.6.0 Altitude of operation msnm 2000 2000
1.7.0 Location   Forest Forest
1.8.0 Type of installation   Exterior Exterior
1.9.0 Standard of manufacture   IEC 60044-5, IEC 60358 IEC 60044-5, IEC 60358
1.10.0 Type of casing   Brown porcelain, IEC 61264 Brown porcelain, IEC 61264
1.11.0 Pollution level Mm/kv 31 31
 
 
  Parameters of system      
2.0.0 Operating voltage KV 60 60
2.1.0 Maximum voltage of material (Um) KV 72.5 72.5
2.2.0 Rated withstand voltage at industrial frequency (Ud) KV 140 140
2.3.0 Rated withstand voltage by lightning impulse KV 350 350
2.40 Assigned frequency (Fr) Hz 60 60
2.5.0 Assigned voltage factor      
a) Permanent   Indicate 1.2
b) During 30 sec   Indicate 1.5
2.6.0 Total capacity pF Indicate 20000
2.7.0 High voltage capacitor (C1) pF Indicate 32012
2.8.0 Intermediate voltage capacitor (C2) pF Indicate 53300
2.9.0 Rated intermediate voltage in open circuit for HF coupling box KV Indicate 13
2.10.0 Number of secondary windings   3 (A measurement core and two for protection) 3
2.11.0 Transformation ratio   60/3 : 100/3: 100/3: 100/3 60/√3/0.1/√3/0.1/√3/0.1/√3 kV
2.12.0 Reference frequency range   Indicate  
a) Precision class of measurement % <= 0.2 0.2
b) Precision class of protection % 5P 3P
2.13.0 Burden VA 30 30
2.14.0 Accuracy class between 25% and 100% of the precision load 0.8 power factor lag    Indicate 0.2/3P
a) between 5% and 80% of the rated voltage   5P 3P
b) between 80% and 120% of the rated voltage   <= 0.2 0.2
c) between 120% and 150% of the rate voltage   5P 3P
2.15.0 Precision load      
a) Winding 1 - measure VA Indicate 30
b) Winding 2 - Protection VA Indicate 30
c) Simultaneous VA Indicate 30
d) Thermal power limit VA Indicate 800
2.16.0 Rated voltage of the system      
a) Primary (Upn) KV 60/√3 60V3   
b) Secondary (Usn) V 100/√3 100V3
2.17.0 Arcing distance Mm   930
2.18.0 Creepage distance according to IEC 60815      
a) For heavy pollution level mm/kv 31.5 31.5
2.19.0 Corriente  de corto circuito a 1 S kA 31.5 31.5
2.20.0 Dynamic current peak kA Indicate 80
 3.0..0 MECHANICAL PARAMETERS      
3.1.0 Total weight Kg Indicate 450
3.2.0 Internal insulation for capactive bodies   Synthetic oil Synthetic oil
3.3.0 Total isolation quantity in electromagnetic unit L Indicate 90
Internal insulation for electromagnetic unit   Mineral oil Mineral oil
3.4.0 Packaging used for mounting electromagnetic unit   Indicate Exporting Package
3.5.0 Diaphragm type   Indicate polypropylene film
3.6.0 Protection grade IP65 for each   si YES
3.7.0 Seismic data (high condition)   Indicate 60KV/2000M
a) Natural frequency (high condition) Hz Indicate 60HZ+-1.5HZ
b) Critical damping coefficient (high condition) % Indicate 0.3
c) Horizontal acceleration g Indicate 0.5
d) Vertical acceleration g Indicate 0.2
3.8.0 Permisible load on terminals      
a) Static N Indicate 2000
b) Dynamic N Indicate 2000
3.9.0 Maximum allowed load by mounting pedestal-type wave trap N Indicate 30
 
 
       
3.10.0 Maximum allowed effor in porcelain daN/mm2 Indicate 20
3.11.0 Mean time between failure (MTBF) Days Offer value 1825
3.12.0 Mean time to repair (MTTR) Days Offer value 365
 4.0.0 ACCESSORIES FOR ASSEMBLY      
4.1.0 Grouping box secondary circuit and electrical system included   Yes YES
4.2.0 Central box of circuits for three voltage transformers   Yes YES
4.3.0 Micro switch for secondary circuit protection (MCB)   Yes, needs to be supplied YES
a) Rated current A Indicate 6
b) Type curve   Z Z
c) Auxiliary contact for position indication and tripping   Yes YES
4.4.0 Protection device ferro-resonance   Yes YES
4.5.0 Sampling valve for mineral oil in electromagnetic box   Gate type GATE TYPE
4.6.0 Oil gauge   Yes YES
4.7.0 Type of plate for alternative corrosive area, low relief   Anodized aluminium ALUMINIUM
4.8.0 Ground terminal   Yes YES
4.9.0 Connecting elements for communication system (carrier system)      
a) Coil drain   No No
b)Descargador   No No
c) Grounding blade high frequency signal   No No
4.10.0 Grounding blade of medium voltage to measure capacitance C1, C2   Yes Yes
4.11.0 Mounting pedestal for wave trap   No No
 33kv/69kv/138kv 60Hz/50Hz Outdoor Capacitor Voltage Transfroemr with Grouping Box

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier