15kv/24kv/38kv 3phases Epoxy Resin Outdoor Assembled Pad Mounted Metering Current Transformer

Product Details
Customization: Available
Application: Instrument
Type: Current Transformer
Still deciding? Get samples of US$ 2000/Piece
Request Sample
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500 RMB
Plant Area
1001~2000 square meters
Find Similar Products

Basic Info.

Model NO.
CT
Operation Condition
Outdoor
Usage
Protection, Measurement
Winding Form
Multilayer Honeycomb Type
Insulating Medium
Epoxy Resin
Installation
Active Type
Transport Package
Wooden
Specification
15KV/27KV/38KV, 50HZ/60HZ,
Trademark
HEMG
Origin
China
Production Capacity
5000

Product Description

15kv/24kv/38kv 3phases Epoxy Resin Outdoor Assembled Pad Mounted Metering Current Transformer
ITEM A CURRENT TRANSFORMER FOR  MEDIUM  VOLTAGE THREE PHASE TYPE BLOCK SUPPORT FOR MEASURE      
ITEM SPECIFICATIONS UNIT REQUIRED GUARANTEED
1 MANUFACTURER   INDICATE HEMG
2 MODEL   INDICATE LZW-12
3 TYPE   BLOCK - SUPPORT BLOCK - SUPPORT
4 POWER VA 15 15
5 RELATION OF TRANSFORMATION A 600-300/5 600-300/5
  VOLTAGE OF OPERATION KV 10 10
6 TYPE OF CONNECTION   STAR STAR
7 PRECISION CLASS   0.2S (EXTENDED RANGE) 0.2S
8 FREQUENCY HZ 60 60
9 NUMBER OF FASES   1 1
10 INSULATION CLASS   "F" ( EPOXY RESIN) "F" ( EPOXY RESIN)
11 COOLING.   AN AN
12 LEVEL OF INSIDE INSULATION ON THE PRIMARY SIDE. KV 17.5 28
13 LEVEL OF INSIDE INSULATION ON THE SECONDARY SIDE. KV 1.1 3
14 APPLICATION.   MEASURE MEASURE
15 MOUNTING.   OUTDOOR OUTDOOR
16 SERVICE.   CONTINUE CONTINUE
17 MANUFACTURING STANDARD.   IEC PUB. 61869 -2 IEC PUB. 61869 -2
18 THERMAL CURRENT (Ith).   100 X IN 100 X IN
19 DYNAMIC CURRENT (Idyn).   2.5 X Ith 2.5 X Ith
20 INSULATION SIDE OF HIGH VOLTAGE-VOLTAGE. MOHM 10,000 10,000
21 ISOLATION HIGH VOLTAGE SIDE - EARTH. MOHM 10,000 10,000
22 INSULATION LOW VOLTAGE SIDE - EARTH. MOHM 1,000 1,000
23 TERMINAL FOR GROUNDING CONNECTION.   YES YES
24 NAMEPLATE.   YES YES
25 METAL BASE FOR FIXING.   YES YES
26 OUTPUT TERMINALS ON CURRENT CIRCUITS.   YES YES
27 INSTALLATION MANUAL AND MANUFACTURER  TEST REPORT  ON EACH EQUIPMENT AT DELIVERY MOMENT.   YES YES
 
ITEM B CURRENT TRANSFORMER FOR  HIGH  VOLTAGE THREE PHASE TYPE BLOCK SUPPORT FOR MEASURE      
ITEM SPECIFICATIONS UNIT REQUIRED GUARANTEED
1 MANUFACTURER   INDICATE HEMG
2 MODEL   INDICATE LZW-36
3 TYPE   BLOCK - SUPPORT BLOCK - SUPPORT
4 POWER VA 15 15
5 RELATION OF TRANSFORMATION A 150-100/5 150-100/5
  VOLTAGE OF OPERATION KV 33 33
6 TYPE OF CONNECTION   STAR STAR
7 PRECISION CLASS   0.2S (EXTENDED RANGE) 0.2S
8 FREQUENCY HZ 60 60
9 NUMBER OF FASES   1 1
10 INSULATION CLASS   "F" ( EPOXY RESIN) "F" ( EPOXY RESIN)
11 COOLING.   AN AN
12 LEVEL OF INSIDE INSULATION ON THE PRIMARY SIDE. KV 38 70
13 LEVEL OF INSIDE INSULATION ON THE SECONDARY SIDE. KV 1.1 3
14 APPLICATION.   MEASURE MEASURE
15 MOUNTING.   OUTDOOR OUTDOOR
16 SERVICE.   CONTINUE CONTINUE
17 MANUFACTURING STANDARD.   IEC PUB. 61869 -2 IEC PUB. 61869 -2
18 THERMAL CURRENT (Ith).   100 X IN 100 X IN
19 DYNAMIC CURRENT (Idyn).   2.5 X Ith 2.5 X Ith
20 INSULATION SIDE OF HIGH VOLTAGE-VOLTAGE. MOHM 10,000 10,000
21 ISOLATION HIGH VOLTAGE SIDE - EARTH. MOHM 10,000 10,000
22 INSULATION LOW VOLTAGE SIDE - EARTH. MOHM 1,000 1,000
23 TERMINAL FOR GROUNDING CONNECTION.   YES YES
24 NAMEPLATE.   YES YES
25 METAL BASE FOR FIXING.   YES YES
26 OUTPUT TERMINALS ON CURRENT CIRCUITS.   YES YES
27 INSTALLATION MANUAL AND MANUFACTURER  TEST REPORT  ON EACH EQUIPMENT AT DELIVERY MOMENT.   YES YES
         
         
 
ITEM B CURRENT TRANSFORMER FOR  HIGH  VOLTAGE THREE PHASE TYPE BLOCK SUPPORT FOR MEASURE      
ITEM SPECIFICATIONS UNIT REQUIRED GUARANTEED
1 MANUFACTURER   INDICATE HEMG
2 MODEL   INDICATE LZW-36
3 TYPE   BLOCK - SUPPORT BLOCK - SUPPORT
4 POWER VA 15 15
5 RELATION OF TRANSFORMATION A 150-100/5 150-100/5
  VOLTAGE OF OPERATION KV 33 33
6 TYPE OF CONNECTION   STAR STAR
7 PRECISION CLASS   0.2S (EXTENDED RANGE) 0.2S
8 FREQUENCY HZ 60 60
9 NUMBER OF FASES   1 1
10 INSULATION CLASS   "F" ( EPOXY RESIN) "F" ( EPOXY RESIN)
11 COOLING.   AN AN
12 LEVEL OF INSIDE INSULATION ON THE PRIMARY SIDE. KV 38 70
13 LEVEL OF INSIDE INSULATION ON THE SECONDARY SIDE. KV 1.1 3
14 APPLICATION.   MEASURE MEASURE
15 MOUNTING.   OUTDOOR OUTDOOR
16 SERVICE.   CONTINUE CONTINUE
17 MANUFACTURING STANDARD.   IEC PUB. 61869 -2 IEC PUB. 61869 -2
18 THERMAL CURRENT (Ith).   100 X IN 100 X IN
19 DYNAMIC CURRENT (Idyn).   2.5 X Ith 2.5 X Ith
20 INSULATION SIDE OF HIGH VOLTAGE-VOLTAGE. MOHM 10,000 10,000
21 ISOLATION HIGH VOLTAGE SIDE - EARTH. MOHM 10,000 10,000
22 INSULATION LOW VOLTAGE SIDE - EARTH. MOHM 1,000 1,000
23 TERMINAL FOR GROUNDING CONNECTION.   YES YES
24 NAMEPLATE.   YES YES
25 METAL BASE FOR FIXING.   YES YES
26 OUTPUT TERMINALS ON CURRENT CIRCUITS.   YES YES
27 INSTALLATION MANUAL AND MANUFACTURER  TEST REPORT  ON EACH EQUIPMENT AT DELIVERY MOMENT.   YES YES
         
         

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier