38kv 50Hz/60Hz Recloser with Manualc/O with 6PCS Voltage Sensror in Tank

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of US$ 8000/Piece
Request Sample
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500 RMB
Plant Area
1001~2000 square meters
  • 38kv 50Hz/60Hz Recloser with Manualc/O with 6PCS Voltage Sensror in Tank
  • 38kv 50Hz/60Hz Recloser with Manualc/O with 6PCS Voltage Sensror in Tank
  • 38kv 50Hz/60Hz Recloser with Manualc/O with 6PCS Voltage Sensror in Tank
  • 38kv 50Hz/60Hz Recloser with Manualc/O with 6PCS Voltage Sensror in Tank
  • 38kv 50Hz/60Hz Recloser with Manualc/O with 6PCS Voltage Sensror in Tank
  • 38kv 50Hz/60Hz Recloser with Manualc/O with 6PCS Voltage Sensror in Tank
Find Similar Products

Basic Info.

Model NO.
CHZ4
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000
Transport Package
Carton with Wooden
Specification
36KV 400A/630A/800A
Trademark
HEMG
Origin
China
Production Capacity
10000

Product Description

38kv 50Hz/60Hz Recloser with Manualc/O with 6PCS Voltage Sensror in Tank
38kv 50Hz/60Hz Recloser with Manualc/O with 6PCS Voltage Sensror in Tank
 
A.- THREE PHASE  RECLOSER  33 KV      
ITEM DESCRIPTION UNIT REQUIRED GUARANTEED
1 RECLOSER      
1.01 COUNTRY   TO INDICATE    CHINA
1.02 MANUFACTURER   TO INDICATE HEMG
1.03 MODEL   TO INDICATE CHZ4
1.04 STANDARD   ANSI C-37.60 ANSI-37.60
1.05 TYPE   OUTDOOR OUTDOOR
1.06 SYSTEM   THREE PHASE THREE PHASE
1.07 OPERATION TYPE   AUTOMATIC AND MANUAL AUTOMATIC AND MANUAL
1.08 ALTITUDE OF OPERATION MO.S.L 2500 OR MORE 4500
  ELECTRIC CHARACTERISTICS      
1.09 OPERATION  VOLTAGE KV 33 33
1.10 MAX, VOLTAGE OF THE EQUIPMENT KV 38 38
1.11 NOMINAL  FREQUENCY HZ 60 60
1.12 NOMINAL CURRENT A 630 630
1.13 NOMINAL SYMETRIC INTERRPTION CURRENT KA 12.5 12.5
1.14 SPECIFIC  LEAKAGE  DISTANCE mm/KV 31 31
1.15 BIL KV 170 170
1.16 DISCHARGE VOLTAGE, DRY, 60 HZ, 1 MINUTE KV 70 70
1.17 DISCHARGE VOLTAGE, WET, 60 HZ, 10 SECONDS KV 60 60
1.18 CYCLE OF WORK ACCORD  ANSI C-37.60   YES YES
1.19 INTERRUPTIION WAY   VACUUM VACUUM
1.20 INSULATION WAY   SOLID DIELECTRIC OR GAS SF6 SOLID DIELECTRIC
1.21 NUMBER OF ELECTRIC OPERATIONS   10000 10000
1.22 CURRENT MEASURE   WITH CURRENT SENSORS WITH CURRENT SENSOR
  INSTALLATION   INDOOR INDOOR
  SYSTEM   SINGLE PHASE SINGLE PHASE
1.23 RELATION OF TRANSFORMATION A 400/1. 400/1
1.24 PRECISION % 1% 1%
1.25 VOLTAGE MEASURE   VOLTAGE SENSORS INTERNAL VOLTAGE SENSORS INTERNAL
1.26 TYPE   CAPACITIVE CAPACITIVE
1.27 INSTALLATION   IN BUSHING IN BUSHING
1.28 PRECISION % 2.5 2.5
1.29 QUANTITY   6 6
1.3 SENSITIVE GROUND FAULT CURRENT DETECTION.   CURENT  TRANSFORMER CURRENT TRANSFORMER
  INSTALLATION.   IN THE TANK (INSIDE THE TANK ) IN TANK
  QUANTITY.   1 1
  TRANSFORMATION RELATION. Ma 200/1.5 200/1.5
  MECHANIC CHARACTERISTICS      
1.3 METALLIC HARDWARE      
  MATERIAL   STAINLESS STAINLESS
  STANDARD OF THE MATERIAL   ASTM A575 ASTM A575
  STANDARD OF HOT GALVANIZED   ASTM A 153 ASTM A 153
  THICKNEES OF GALAVANIZATION MIN gr/CM2 800 800
1.31 MOUNTING   ON CIRCULAR POLE ON CIRCULAR POLE
1.32 MECHANISM OF OPERATION   MAGNETIC ACTUATOR MAGNETIC ACTUATOR
1.33 POSITION INDICATOR   VISIBLE FROM THE SOIL VISIBLE FROM THE SOIL
1.34 OPERATION BETWEEN POLE WITH  HOOK   YES YES
1.35 MANUAL LOCKING EMERGENCY (ATTACHED DRAWING)   YES YES
1.36 TOOL PROVIDED WITH MANUAL CONTROL   YES YES
1.37  WITH LIFTING HOOKS   YES YES
1.38 INDICATES THE LIFE OF CONTACTS   YES YES
1.39 NUMBER OF MECHANICS OPERATION   10000 OR MORE 10000 OR MORE
1.40 FULLY  ASSEMBLED   YES YES
1.41 WEIGHT        
  PRINCIPAL TANK KG TO INDICATE 135
  CONTROL BOX KG TO INDICATE 35
2 TANK      
2.01 MATERIAL   STAINLESS STEEL STAINLESS STEEL
  CONSTRUCTION REQUIREMENTS   INDICATE THE STANDARD INDICATE THE STANDARD
2.02  COATING OF TIN IN TERMINALS AND CONDUCTIVE  PARTS.   8 um 8 um
2.03 PROTECTION DEGREE   Able to withstand pressure fresh water cleaning insulators. Able to withstand pressure fresh water cleaning insulators.
3 BUSHINGS      
3.01 COUNTRY   TO INDICATE CHINA
3.02 MANUFACTURER   TO INDICATE HEMG
3.03 STANDARD   ASTM D624, DIN 63504,IEC 60587,ASTM G154, AST G 155. ASTM D624, DIN 63504,IEC 60587,ASTM G154, AST G 155.
3.04 CHARACTERISTICS OF MANUFACTURE      
  MATERIAL  OF CORE   FIBER GLASS OR RESYN RESYN
  INSULATION MATERIAL OF COVER HOUSING AND SHEDS   Cycloaliphatic EPOXY RESIN Cycloaliphatic EPOXY RESIN
  ELONGATION AT BREAK % 450 ( ACCORD STANDARD DIN 53504 ) 450
3.05 TEAR RESISTANCE. N/M MAJOR OF 20 ( Standard ASTM D624) 20
3.06 TRACKING AND EROSION RESISTANCE.   CLASS 2A,4.5 ( IEC 60587 ) CLASS 2A,4.5 ( IEC 60587 )
3.07 TESTING OF RESISTANCE TO UV RAYS.   ACCORDING ASTM G154 AND ASTM G155 ACCORDING ASTM G154 AND ASTM G155
3.08 RANGE OF SECTION OF DRIVERS.   16  TO 120 MM2 16  TO 120 MM2
3.09 CONDUCTOR MATERIAL OF ELIGIBLE.   CU/AL , CU/CU , AL/AL CU
4 SYSTEM OF CONTROL AND PROTECTION      
4.01 COUNTRY   SAME COUNTRY  INDICATE POINT 1.1 China
4.02 STANDARD OF MANUFACTURE   ANSI / IEEE 37.90 ANSI / IEEE 37.90
4.03 INSTALLATION   OUTDOOR OUTDOOR
4.04 MANUFACTURER   SAME MANUFACTURER INDICATE POINT 1.2 HEMG
4.05 CATALOGUE   TO INDICATE English Version
4.06 MODEL OF ELECTRONIC SYSTEM   TO INDICATE CHZ4
  CONTROL   BOX      
4.07 MATERIAL   STAINLESS STEEL Stainless Steel
4.08 THICKNESS   2 MM 2mm
4.09 SURFACE   BRIGHT PASSIVATING Bright Passivating
4.10 COLOUR   TO INDICATE RAL7035
4.11 PROTECTION DEGRE OF THE BOX      
  CLOSE OPEN   IP65 IP65
  INSULATION VOLTAGE TO 1 MINUTE   2 KV 2KV
  INSULATION VOLTAGE TO IMPULSE   6 KVp 6 KVp
  SUPPORT TO INTERFERENCE TESTING ACCORDING TO STANDARDS:   SWC ANSI C37.90.1, IEC 61000-4-4- IEC 61000-4-4
  IMMUNITY TO INTERFERENCE RADIO WAVES.   IEC 255-22-3 CLASS, ANSI C37.90.2 IEC 255-22-3 CLASS
4.12 WITH NAMEPLATE   YES Yes
  CHARACTERISTICS         
4.13 FUNCTION   WITH MICROPROCESSOR Yes
4.14 PRINCIPAL PROTECTIONS   50/51,50N/51N,SEF,25,27,59,59N, 67 50/51,50N/51N,SEF,25,27,59,67
4.15 SECONDARY  PROTECTIONS   46.81 46/81
4.16 ADJUSTEMENT  GROUPS   2 MIN 3 Groups
4.17 MIN CURRENT OF SHOOT      
  FAILURE BETWEEN PHASES A 20 or minor ≤20A
  FAILURE TO GROUND A 10 or minor ≤10A
  SENSITIVY  FAILURE A 1 or minor ≤1A
4.18 SETTING ALLOWS PARAMETERS PROTECTION   YES Setting can Parameter
  IEC STANDARD CURVES   YES IEC and IEEE curves
  CUSTOM CURVES   YES IEC and IEEE curves
4.19 FAILURE TO GROUND   YES Yes
4.20 MINIMUN VOLTAGES   YES 27
4.21 OVER VOLTAGE   YES 59
4.22 STATUS  INDICATOR OF RECLOSERS      
  PARAMETERS   YES Yes
  POSITION OF THE EQUIPMENTS   YES Yes
4.23 ALLOWS STORAGE OPERATING EVENTS      
  OPEN OR CLOSE   YES Yes
  LOSS VOLTAGE   YES Yes
  OPERATION CURRENT   YES Yes
4.24 REPORT FUNCTIONS      
  EVENT REGISTRATION NUMBER SYSTEM   2048 4096
  EVENT REGISTRATION NUMBER OF DIAGNOSIS   512 1024
  EVENT OF PERFIL LOAD REGISTRATION   512 1024
  REGSITER OF NUMBER OF SHOOTS   YES Yes
  REGISTER OF COUNTER OF FAILURES   YES Yes
  NUMER OF REGISTER WAVE FORM   32 32
  REGISTRATION  FORM   COMTRADE or software application Comtrade type
         
4.25 REPORT FUNCTIONS      
  ERROR IN THE MEASUREMENT     Yes
  BEFORE FAILURE   1% OR MINOR ≤1%
  AFTER FAILURE   3% OR MINOR ≤1%
  MEASSUREMENTS OF INSTANTANEOUS VALUES   V,I,F,P,Q V,I,F,PF,P,Q
  ACTIVE AND REACTIVE POWER   YES Active and Reactive Counter
4.26  THE CONTROL MUST HAVE TO DISPLAY DATA AND ADJUSTMENT   YES 4.3 inch Color LCD touch screen
4.27 COMMUNICATIONS PROTOCOL (READY FOR INTEGRATION WITH SYSTEMS SCADA)   DNP 3.0 DNP3.0
4.28 COMMUNICATION PORTS      
  ETHERNET   YES RJ45
  COMMUNICATION WITH PERSONAL COMPUTER   RS232, ETHERNET RJ45,Wi-Fi,Ethernet
  COMMUNICATION  READ DATA   RS232, ETHERNET, RS485 Ethernet and RS485
4.29 OPTION be commanded remotely WITH RADIO MODEM OR GSM MODEM.   YES GSM Modem
  EFFORTS TO SAFE OPERATION.   YES Yes
  INPUT AND OUTPUT NEEDED FOR THIS EFFECT.   YES Yes
4.3 CONFIURATION  SOFTWARE      
  ENVIROMENT   WINDOWS Windows
  SECURITY SYSTEM   WITH PASSWORD With Password
  INFORMATION DISCHARGE   YES Yes
  PROGRAMMING IN REMOTELY   YES By Ethernet
5 AUXILIAR ENERGY FEEDER SYSTEM      
  SYSTEM   SINGLE PHASE  
  INCLUDE AUXILIAR TRANSFORMER FOR CONTROL BOX   YES  
5.01 BATTERY      
  COUNTRY   TO INDICATE China
  MANUFACTURER   TO INDICATE HEMG
  TYPE   TO INDICATE NP7-12
  NOMINAL VOLTAGE   TO INDICATE DC24V
  NUMBER OF UNIT OPERATING VOLTAGE TO FAILURES.   10 OR MORE 2
  MEASURING THE CONDITION OF THE BATTERY.   YES Yes
  BATTERY LIFE IN FAILURE OF LACK OF VOLTAGE.   48 HOURS 48 Hours
  INCLUDED IN THE CABINET OF CONTROL   YES Yes
5.02 SYSTEM OF CHARGE OF THE BATTERIES      
  COUNTRY   TO INDICATE China
  MANUFACTURER   TO INDICATE HEMG
  AUXILIAR VOLTAGE   220 VAC AC 220V
  SYSTEM   SINGLE PHASE Single Phase
  COMPATIBLE WITH SPECIFIED BATTERIES   YES Yes
  INCLUDED IN THE CABINET OF CONTROL   YES Yes
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier