Basic Info.

Model NO.
CT
Phase
Three
Operation Condition
Outdoor
Usage
Protection, Measurement
Winding Form
Multilayer Honeycomb Type
Insulating Medium
Epoxy Resin
Installation
Active Type
Transport Package
Wooden
Specification
15KV/27KV/38KV, 50HZ/60HZ,
Trademark
HEMG
Origin
China
Production Capacity
5000

Product Description

66kv Single Phase Outdoor Epoxy Resin Current Transformer
ITEM K CURRENT TRANSFORMER FOR HIGH VOLTAGE THREE PHASE TYPE BLOCK SUPPORT FOR MEASURE      
ITEM SPECIFICATIONS UNIT REQUIRED GUARANTEED
1 MANUFACTURER   INDICATE HEMG
2 MODEL   INDICATE LZW-66
3 TYPE   BLOCK - SUPPORT BLOCK - SUPPORT
4 POWER VA 15 15
5 RELATION OF TRANSFORMATION A 50-25/5 50-25/5
  VOLTAGE OF OPERATION KV 60 60
6 TYPE OF CONNECTION   STAR STAR
7 PRECISION CLASS   0.2S (EXTENDED RANGE) 0.2S
8 FREQUENCY HZ 60 60
9 NUMBER OF FASES   1 1
10 INSULATION CLASS   "F" ( EPOXY RESIN) "F"( EPOXY RESIN)
11 COOLING.   AN AN
12 LEVEL OF INSIDE INSULATION ON THE PRIMARY SIDE. KV 70 140
13 LEVEL OF INSIDE INSULATION ON THE SECONDARY SIDE. KV 1.1 3
14 APPLICATION.   MEASURE MEASURE
15 MOUNTING.   OUTDOOR OUTDOOR
16 SERVICE.   CONTINUE CONTINUE
17 MANUFACTURING STANDARD.   IEC PUB. 61869 -2 IEC PUB. 61869 -2
18 THERMAL CURRENT (Ith).   100 X IN 100 X IN
19 DYNAMIC CURRENT (Idyn).   2.5 X Ith 2.5 X Ith
20 INSULATION SIDE OF HIGH VOLTAGE-VOLTAGE. MOHM 10,000 10,000
21 ISOLATION HIGH VOLTAGE SIDE - EARTH. MOHM 10,000 10,000
22 INSULATION LOW VOLTAGE SIDE - EARTH. MOHM 1,000 1,000
23 TERMINAL FOR GROUNDING CONNECTION.   YES YES
24 NAMEPLATE.   YES YES
25 METAL BASE FOR FIXING.   YES YES
26 OUTPUT TERMINALS ON CURRENT CIRCUITS.   YES YES
27 INSTALLATION MANUAL AND MANUFACTURER  TEST REPORT  ON EACH EQUIPMENT AT DELIVERY MOMENT.   YES YES


 
ITEM K CURRENT TRANSFORMER FOR HIGH VOLTAGE THREE PHASE TYPE BLOCK SUPPORT FOR MEASURE      
ITEM SPECIFICATIONS UNIT REQUIRED GUARANTEED
1 MANUFACTURER   INDICATE HEMG
2 MODEL   INDICATE LZW-66
3 TYPE   BLOCK - SUPPORT BLOCK - SUPPORT
4 POWER VA 15 15
5 RELATION OF TRANSFORMATION A 50-25/5 50-25/5
  VOLTAGE OF OPERATION KV 60 60
6 TYPE OF CONNECTION   STAR STAR
7 PRECISION CLASS   0.2S (EXTENDED RANGE) 0.2S
8 FREQUENCY HZ 60 60
9 NUMBER OF FASES   1 1
10 INSULATION CLASS   "F" ( EPOXY RESIN) "F"( EPOXY RESIN)
11 COOLING.   AN AN
12 LEVEL OF INSIDE INSULATION ON THE PRIMARY SIDE. KV 70 140
13 LEVEL OF INSIDE INSULATION ON THE SECONDARY SIDE. KV 1.1 3
14 APPLICATION.   MEASURE MEASURE
15 MOUNTING.   OUTDOOR OUTDOOR
16 SERVICE.   CONTINUE CONTINUE
17 MANUFACTURING STANDARD.   IEC PUB. 61869 -2 IEC PUB. 61869 -2
18 THERMAL CURRENT (Ith).   100 X IN 100 X IN
19 DYNAMIC CURRENT (Idyn).   2.5 X Ith 2.5 X Ith
20 INSULATION SIDE OF HIGH VOLTAGE-VOLTAGE. MOHM 10,000 10,000
21 ISOLATION HIGH VOLTAGE SIDE - EARTH. MOHM 10,000 10,000
22 INSULATION LOW VOLTAGE SIDE - EARTH. MOHM 1,000 1,000
23 TERMINAL FOR GROUNDING CONNECTION.   YES YES
24 NAMEPLATE.   YES YES
25 METAL BASE FOR FIXING.   YES YES
26 OUTPUT TERMINALS ON CURRENT CIRCUITS.   YES YES
27 INSTALLATION MANUAL AND MANUFACTURER  TEST REPORT  ON EACH EQUIPMENT AT DELIVERY MOMENT.   YES YES