69kv Silicon Rubber Line Post Insulator

Product Details
Customization: Available
Application: High-voltage
Material: Porcelain
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500 RMB
Plant Area
1001~2000 square meters
  • 69kv Silicon Rubber Line Post Insulator
  • 69kv Silicon Rubber Line Post Insulator
  • 69kv Silicon Rubber Line Post Insulator
  • 69kv Silicon Rubber Line Post Insulator
  • 69kv Silicon Rubber Line Post Insulator
Find Similar Products

Basic Info.

Model NO.
SILICON
Usage
High Voltage Power Transmission, Insulation
Size of Bearing Capacity
70KN
Certification
ISO9001
Color
Brown
Transport Package
Wooden
Specification
69KV
Trademark
HEMG
Origin
China
Production Capacity
100000

Product Description

69kv Silicon Rubber Line Post Insulator



 
ITEM 1: HIGH VOLTAGE INSULATOR TYPE LINE POST, 69 kV, ANSI CLASS 57-36 REQUESTED
 
OFFERED  
 
ITEM DESCRIPTION SPECIFICATION    
1 MATERIAL SILICON RUBBER processed,  YES  
1.1 Manufacturing standard NEMA / ANSI C29-7 YES  
1.2 Class ANSI 57-36 YES  
1.3 Mounting / position Pole / d horizontal  YS  
1.4 Hardware used NOTE 2  YES  
2 DISTANCES REVIEWS      
2.1 Creepage > = 1755 mm  YES  
2.2 Distance bow > = 489 mm (19.25 ")  YES  
3 MECHANICAL      
3.1 Cantilever Strength > = 1270 kg /12.5kN  YES  
3.2 Tensile strength > = 2,270 kg  YES  
4 ELECTRICAL VALUES      
4.1 Typical application voltage 69 kV  YES  
4.2 Flashover voltage low frequency dry > = 260 kV  YES  
4.3 Flashover voltage low frequency wet > = 230 kV  YES  
4.5 Flashover voltage of the positive pulse critical > = 430 kV  YES  
4.6 Flashover voltage of the negative pulse critical > = 520 kV  YES  
4.7 Basic insulation level According to requirements of the EDs yes  
5 RADIO INFLUENCE      
5.1 Test Voltage 44 kV  yes  
5.2 RIV max 1000 kHz 200 microvolts  yes  
6 DIMENSIONS      
6.1 Nominal diameter of insulating part
 
203.2 mm (8 ")  yes  
6.2 Height specify  740MM  
6.3 Distance between holes in the base specify  305MM  
6.4 Length of specify  740MM  
7 CONSTRUCTION DETAILS      
7.1 Color Grey  YES  
7.2 galvanized hot  YES  
7.3 Standard galvanized ASTM A153  YES  
7.4 Thickness of galvanized fittings 85 microns  YES  
7.5 Type of Base ANSI C29-7 (flat)  YES  
7.5.1 Slot width (diameter)           13/16 "  YES  
7.5.2 minimum length 15-16 "  YES  
8 CONDITIONS OF POLLUTION NOTE 3  YES  
9 PACKAGING      
9.1 Packaging Lot According to requirements of the EDs  YES  
9.2 Units per Lot    1PC/1PACKAGE  
9.3 Approximate Net Weight    50KG  
10 DOCUMENTS AND CERTIFICATES OF MANDATORY NEMA / ANSI C29-7, NOTE 5  TYPE TESTING OF CHINA  
10.1 Test Design ANSI C29-1  YES  
11 Printing NOTE 4  YES  
12 SAMPLES According to requirements of the ED's  YES  
NOTES:        
1 The insulating raw material shall be commercial quality excellent.
Porcelain insulators shall be manufactured by wet process.
All exposed porcelain insulators surface must be covered with a hard glassy, smooth, shiny and impervious to moisture compression type, which allows, through the natural rain water washing, easily kept free of dust and dirt waste caused by environmental pollution. The total surface of the insulator, except the burn area, shall be glazed and free from imperfections.
The porcelain used porosities not have to file; must be of high dielectric strength, high mechanical strength, chemically inert and high-melting.
 If the composition of the alternatives in isolation (polymer or polymer concrete) must attach all relevant technical, containing specifications, standards and the comparative benefits with the required material (porcelain), for proper analysis by the CNEL without this meaning explicit acceptance. The technical committee or delegate approved alternative process if exposed with appropriate supporting rationale.           
 
2 The fittings shall be forged steel and hot dip galvanized according to ASTM A153 norms for hardware. Compliance with the shape of the base Line Post Insulator shall be subject to the provisions of ANSI standard C29-7 1996 (rev 2002), and the bolts and nuts shall comply with the test design C29-1 ANSI standard under explained in section 8.3.3 of ANSI C29-7.
 
 
3 The insulators in their normal use may be in an environment with different degrees of pollution, so each ED will considerations in the selection of insulators under atmospheric pollution. For the particular case of HD CNEL cycle work (heavy duty) is requested.  
4 Cada aislador tiene que estar marcado en forma legible e indeleble y durable en el tiempo con la información mínima  
1- Logotipo o marca del fabricante; y  
2- Año de fabricación del aislador.  
5 Certificates of conformity of product or compliance required herein must be issued by accredited certification bodies, documentation to be endorsed by the OAE.
 
 
In the case of test reports, they must be issued by accredited laboratories, documentation to be endorsed by the OAE. These certificates and reports, will be a requirement that bidders submit to the procurement process.
 
 



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier