Customization: | Available |
---|---|
Breaking Capacity: | High Voltage Circuit Breakers |
Operation: | Electric Type |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
. table 1 | ||||||||||||||||||
No. Name | Unit | Data | Data | Data | Data | Data | Data | |||||||||||
1 | Rated voltage | kV | 12 | 12 | 12 | 12 | 12 | 12 | ||||||||||
2 | Rated current | A | 630, 1250 | 630, 1250 | 630, 1250, 1600 | 1250, 1600, 2000 | 2000, 2500, 3150,4000, 5000 | 3 150 4000 5000 | ||||||||||
3 | Rated insulation level | 1min power frequency withstand voltage | kV | 42 | 42 | 42 | 42 | 42 | 42 | |||||||||
Rated lightning impulse withstand voltage | kV | 75 | 75 | 75 | 75 | 75 | 75 | |||||||||||
4 | Rated short-circuit breaking current | kA | 16 | 20 | 25 | 31.5 | 40 | 50 | ||||||||||
5 | Rated short-circuit making current (peak value) | kA | 40 | 50 | 63 | 80 | 100 | 130 | ||||||||||
6 | Rated peak withstand current | kA | 40 | 50 | 63 | 80 | 100 | 130 | ||||||||||
7 | Rated short-time withstand current | kA | 16 | 20 | 25 | 31.5 | 40 | 50 | ||||||||||
8 | Break times of rated short-circuit making current | Times | 50 | 50 | 50 | 50 | 30 | 20 | ||||||||||
9 | Rated duration of short-circuit | s | 4 | 4 | 4 | 4 | 4 | 4 | ||||||||||
10 | Rated operating sequence | O-t-CO-180s-CO* | O-t-CO-180s-CO* | O-t-CO-180s-CO* | O-t-CO-180s-CO* | O-t-CO-180s-CO* | O-t-CO-180s-CO* | |||||||||||
11 | Mechanical endurance | Times | 20000 | 20000 | 20000 | 20000 | 10000 | 10000 | ||||||||||
12 | Rated single capacitor bank breaking current | A | 630 | 630 | 630 | 630 | ||||||||||||
13 | Rated back-to-back capacitor bank breaking current | 400 | 400 | 400 | 400 | |||||||||||||
*16kA, 20kA, 25kA, 31.5kA | t=0.3s 40kA t=180s | |||||||||||||||||
Stored energy motor | Stored energy motor adopts permanent-magnet DC motor. See table 2 | table 2 | ||||||||||||||||
Model | Rated voltage(V) | Rated output power(W) | Normal working voltage range(V) | Stored energy time under rated voltage(s) | ||||||||||||||
ZYJ55-1 | DC110 | DC220 | 70 | 85%~110% rated voltage | 10 | |||||||||||||
Operating voltage of AC or DC is available | ||||||||||||||||||
Technical parameters of opening, closing coils . See table 3. | table 3 | |||||||||||||||||
Closing coil | Opening coil | Remarks | ||||||||||||||||
Rated operating voltage(V) | DC220 AC220 | DC110 AC110 | DC220 DC110 AC220,AC110,30VDC | No opening subject to the operating voltage of opening coil below 30% of rated operating voltage. | ||||||||||||||
Coil power(W) | 368 | 368 | ||||||||||||||||
Normal working voltage range | AC 85%~110% Rated voltage DC 80%~110% Rated voltage | AC 85%~120% Rated voltage DC 65%~120% Rated voltage |