24kv Indoor Sf6 Insulating Load Break Switch for Ring Main Unit

Product Details
Customization: Available
Type: High-voltage
Structure: Three-column Disconnector
Still deciding? Get samples of US$ 1000/Piece
Request Sample
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500 RMB
Plant Area
1001~2000 square meters
  • 24kv Indoor Sf6 Insulating Load Break Switch for Ring Main Unit
  • 24kv Indoor Sf6 Insulating Load Break Switch for Ring Main Unit
  • 24kv Indoor Sf6 Insulating Load Break Switch for Ring Main Unit
  • 24kv Indoor Sf6 Insulating Load Break Switch for Ring Main Unit
  • 24kv Indoor Sf6 Insulating Load Break Switch for Ring Main Unit
Find Similar Products

Basic Info.

Model NO.
GLBS
Installation
Indoor High-voltage
Operation
Electric
Grounding Mode
Grounding
Certification
IS9001, ISO9001
Transport Package
Wooden
Specification
24kv
Trademark
HEMG
Origin
China
Production Capacity
50000

Product Description

24kv Indoor Sf6 Insulating Load Break Switch for Ring Main Unit
24kv Indoor Sf6 Insulating Load Break Switch for Ring Main Unit
24kv Indoor Sf6 Insulating Load Break Switch for Ring Main Unit


 
Important parameter
S/N Item Descriptiop Unit value
HVF6(FLN56)-24/630-20
1 Rated voltage     KV 24
2 Rated insulating level Short time power frequency withstand voltage 1min 65
Lightning impulse withstand voltage(peak) 125
Operation mechanism and auxiliary circuit power frequency voltage V 2000
3 Rated frequency Hz 50
4 Rated current  In(A) A 630
5 Rated Active load breaking current  
6 Rated closed loop breaking current  
7 rated cable charging breaking current 10
8 Rated no-load transformer breaking capacity kVA 2500
9 Short time withstand current kA 20
10 Rated short-circuit duration(main circuit/earth circuit)    S 3/2
11 Rated peak peak withstand current KA 50
12 Rated short-circuit breaking current  
13 Rated short circuit closing current 50
14 Mechanical endurance times 2000
15 Main circuit resistance μΩ ≤80
16 Rated transfer current A  
17 Rated opening operation voltage(tripping operation) V AC220,110
DC220,110,48
18 Rated opening operation current(tripping operation) A AC  1,2
DC0.77 1.55 3.53
19 Energy charging motor rated voltage(only charging to motor) V AC220,110
DC220,110,48
20 Rated power of energy charging motor  W 60
21 Rated pressure to SF6 gas (Gage pressure 20ºC) Mpa 0.04~0.05
22 SF6 gas leakage per year   ≤0.5%
 
Important parameter
S/N Item Descriptiop Unit value
HVF6(FLN56)-24/630-20
1 Rated voltage     KV 24
2 Rated insulating level Short time power frequency withstand voltage 1min 65
Lightning impulse withstand voltage(peak) 125
Operation mechanism and auxiliary circuit power frequency voltage V 2000
3 Rated frequency Hz 50
4 Rated current  In(A) A 630
5 Rated Active load breaking current  
6 Rated closed loop breaking current  
7 rated cable charging breaking current 10
8 Rated no-load transformer breaking capacity kVA 2500
9 Short time withstand current kA 20
10 Rated short-circuit duration(main circuit/earth circuit)    S 3/2
11 Rated peak peak withstand current KA 50
12 Rated short-circuit breaking current  
13 Rated short circuit closing current 50
14 Mechanical endurance times 2000
15 Main circuit resistance μΩ ≤80
16 Rated transfer current A  
17 Rated opening operation voltage(tripping operation) V AC220,110
DC220,110,48
18 Rated opening operation current(tripping operation) A AC  1,2
DC0.77 1.55 3.53
19 Energy charging motor rated voltage(only charging to motor) V AC220,110
DC220,110,48
20 Rated power of energy charging motor  W 60
21 Rated pressure to SF6 gas (Gage pressure 20ºC) Mpa 0.04~0.05
22 SF6 gas leakage per year   ≤0.5%

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier