38kv Pole Mounted 630A 60z Recloser

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of US$ 10000/Piece
Request Sample
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500 RMB
Plant Area
1001~2000 square meters
  • 38kv Pole Mounted 630A 60z Recloser
  • 38kv Pole Mounted 630A 60z Recloser
  • 38kv Pole Mounted 630A 60z Recloser
  • 38kv Pole Mounted 630A 60z Recloser
  • 38kv Pole Mounted 630A 60z Recloser
Find Similar Products

Basic Info.

Model NO.
CHZ4
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000
Transport Package
Wooden
Specification
38kv 630a 60hz
Trademark
HEMG
Origin
China
Production Capacity
10000

Product Description

38kv Pole Mounted 630A 60z Recloser38kv Pole Mounted 630A 60z Recloser

38kv Pole Mounted 630A 60z Recloser
38kv Pole Mounted 630A 60z Recloser
38kv Pole Mounted 630A 60z Recloser
38kv Pole Mounted 630A 60z Recloser
A.- THREE PH ASE  RECLOSER  33 KV        
ITEM DESCRIPTION UNIT REQUIRED GUARANTEED
1 RECLOSER      
1.01 COUNTRY   TO INDICATE CHINA
1.02 MANUFACTURER   TO INDICATE HEMG
1.03 MODEL   TO INDICATE CHZ4
1.04 STANDARD   ANSI C-37.60 YES
1.05 TYPE   OUTDOOR YES
1.06 SYSTEM   THREE PHASE YES
1.07 OPERATION TYPE   AUTOMATIC AND MANUAL YES
1.08 ALTITUDE OF OPERATION MO.S.L 2500 OR MORE YES
  ELECTRIC CHARACTERISTICS     YES
1.09 OPERATION  VOLTAGE KV 33 YES
1.10 MAX, VOLTAGE OF THE EQUIPMENT KV 38 YES
1.11 NOMINAL  FREQUENCY HZ 60 YES
1.12 NOMINAL CURRENT A 630 YES
1.13 NOMINAL SYMETRIC INTERRPTION CURRENT KA 12.5 YES
1.14 SPECIFIC  LEAKAGE  DISTANCE mm/KV 31 YES
1.15 BIL KV 170 YES
1.16 DISCHARGE VOLTAGE, DRY, 60 HZ, 1 MINUTE KV 70 YES
1.17 DISCHARGE VOLTAGE, WET, 60 HZ, 10 SECONDS KV 60 YES
1.18 CYCLE OF WORK ACCORD  ANSI C-37.60   YES YES
1.19 INTERRUPTIION WAY   VACUUM YES
1.20 INSULATION WAY   SOLID DIELECTRIC OR GAS SF6 YES
1.21 NUMBER OF ELECTRIC OPERATIONS   10000 YES
1.22 CURRENT MEASURE   WITH CURRENT SENSORS YES
  INSTALLATION   INDOOR YES
  SYSTEM   SINGLE PHASE YES
1.23 RELATION OF TRANSFORMATION A 400/1. YES
1.24 PRECISION % 1% YES
1.25 VOLTAGE MEASURE   VOLTAGE SENSORS INTERNAL YES
1.26 TYPE   CAPACITIVE YES
1.27 INSTALLATION   IN BUSHING YES
1.28 PRECISION % 2.5 YES
1.29 QUANTITY   6 YES
1.3 SENSITIVE GROUND FAULT CURRENT DETECTION.   CURENT  TRANSFORMER YES
  INSTALLATION.   IN THE TANK (INSIDE THE TANK ) IN CONTROL  TANK
  QUANTITY.   1 YES
  TRANSFORMATION RELATION. Ma 200/1.5 YES
  MECHANIC CHARACTERISTICS      
1.3 METALLIC HARDWARE      
  MATERIAL   STAINLESS YES
  STANDARD OF THE MATERIAL   ASTM A575 YES
  STANDARD OF HOT GALVANIZED   ASTM A 153 YES
  THICKNEES OF GALAVANIZATION MIN gr/CM2 800 YES
1.31 MOUNTING   ON CIRCULAR POLE YES
1.32 MECHANISM OF OPERATION   MAGNETIC ACTUATOR YES
1.33 POSITION INDICATOR   VISIBLE FROM THE SOIL YES
1.34 OPERATION BETWEEN POLE WITH  HOOK   YES YES
1.35 MANUAL LOCKING EMERGENCY (ATTACHED DRAWING)   YES YES
1.36 TOOL PROVIDED WITH MANUAL CONTROL   YES YES
1.37  WITH LIFTING HOOKS   YES YES
1.38 INDICATES THE LIFE OF CONTACTS   YES YES
1.39 NUMBER OF MECHANICS OPERATION   10000 OR MORE YES
1.40 FULLY  ASSEMBLED   YES YES
1.41 WEIGHT        YES
  PRINCIPAL TANK KG TO INDICATE 75KG
  CONTROL BOX KG TO INDICATE 35KG
2 TANK      
2.01 MATERIAL   STAINLESS STEEL YES
  CONSTRUCTION REQUIREMENTS   INDICATE THE STANDARD YES
2.02  COATING OF TIN IN TERMINALS AND CONDUCTIVE  PARTS.   8 um YES
2.03 PROTECTION DEGREE   Able to withstand pressure fresh water cleaning insulators. YES
3 BUSHINGS      
3.01 COUNTRY   TO INDICATE ZSW
3.02 MANUFACTURER   TO INDICATE HM
3.03 STANDARD   ASTM D624, DIN 63504,IEC 60587,ASTM G154, AST G 155.
 
YES
3.04 CHARACTERISTICS OF MANUFACTURE      
  MATERIAL  OF CORE   FIBER GLASS OR RESYN YES
  INSULATION MATERIAL OF COVER HOUSING AND SHEDS   Cycloaliphatic EPOXY RESIN YES
  ELONGATION AT BREAK % 450 ( ACCORD STANDARD DIN 53504 ) YES
3.05 TEAR RESISTANCE. N/M MAJOR OF 20 ( Standard ASTM D624) YES
3.06 TRACKING AND EROSION RESISTANCE.   CLASS 2A,4.5 ( IEC 60587 ) YES
3.07 TESTING OF RESISTANCE TO UV RAYS.   ACCORDING ASTM G154 AND ASTM G155 YES
3.08 RANGE OF SECTION OF DRIVERS.   16  TO 120 MM2 YES
3.09 CONDUCTOR MATERIAL OF ELIGIBLE.   CU/AL , CU/CU , AL/AL YES
4 SYSTEM OF CONTROL AND PROTECTION       
4.01 COUNTRY   SAME COUNTRY  INDICATE POINT 1.1 YES
4.02 STANDARD OF MANUFACTURE   ANSI / IEEE 37.90 YES
4.03 INSTALLATION   OUTDOOR YES
4.04 MANUFACTURER   SAME MANUFACTURER INDICATE POINT 1.2 YES
4.05 CATALOGUE   TO INDICATE YES
4.06 MODEL OF ELECTRONIC SYSTEM   TO INDICATE CHK4
  CONTROL   BOX      
4.07 MATERIAL   STAINLESS STEEL YES
4.08 THICKNESS   2 MM YES
4.09 SURFACE   BRIGHT PASSIVATING YES
4.10 COLOUR   TO INDICATE GREY
4.11 PROTECTION DEGRE OF THE BOX      
  CLOSE OPEN   IP65 CLOSE IP65
  INSULATION VOLTAGE TO 1 MINUTE   2 KV YES
  INSULATION VOLTAGE TO IMPULSE   6 KVp YES
  SUPPORT TO INTERFERENCE TESTING ACCORDING TO STANDARDS:   SWC ANSI C37.90.1, IEC 61000-4-4- YES
  IMMUNITY TO INTERFERENCE RADIO WAVES.   IEC 255-22-3 CLASS, ANSI C37.90.2 YES
4.12 WITH NAMEPLATE   YES YES
  CHARACTERISTICS          
4.13 FUNCTION   WITH MICROPROCESSOR YES
4.14 PRINCIPAL PROTECTIONS   50/51,50N/51N,SEF,25,27,59,59N, 67 YES
4.15 SECONDARY  PROTECTIONS   46.81 YES
4.16 ADJUSTEMENT  GROUPS   2 MIN YES
4.17 MIN CURRENT OF SHOOT     YES
  FAILURE BETWEEN PHASES A 20 or minor YES
  FAILURE TO GROUND A 10 or minor YES
  SENSITIVY  FAILURE A 1 or minor YES
4.18 SETTING ALLOWS PARAMETERS PROTECTION   YES YES
  IEC STANDARD CURVES   YES YES
  CUSTOM CURVES   YES YES
4.19 FAILURE TO GROUND   YES YES
4.20 MINIMUN VOLTAGES   YES YES
4.21 OVER VOLTAGE   YES YES
4.22 STATUS  INDICATOR OF RECLOSERS     YES
  PARAMETERS   YES YES
  POSITION OF THE EQUIPMENTS   YES YES
4.23 ALLOWS STORAGE OPERATING EVENTS     YES
  OPEN OR CLOSE   YES YES
  LOSS VOLTAGE   YES YES
  OPERATION CURRENT   YES YES
4.24 REPORT FUNCTIONS     YES
  EVENT REGISTRATION NUMBER SYSTEM   2048 YES
  EVENT REGISTRATION NUMBER OF DIAGNOSIS    512 YES
  EVENT OF PERFIL LOAD REGISTRATION   512 YES
  REGSITER OF NUMBER OF SHOOTS   YES YES
  REGISTER OF COUNTER OF FAILURES   YES YES
  NUMER OF REGISTER WAVE FORM   32 YES
  REGISTRATION  FORM   COMTRADE or software application YES
         
4.25 REPORT FUNCTIONS      
  ERROR IN THE MEASUREMENT      
  BEFORE FAILURE   1% OR MINOR YES
  AFTER FAILURE   3% OR MINOR YES
  MEASSUREMENTS OF INSTANTANEOUS VALUES   V,I,F,P,Q YES
  ACTIVE AND REACTIVE POWER   YES YES
4.26  THE CONTROL MUST HAVE TO DISPLAY DATA AND ADJUSTMENT   YES YES
4.27 COMMUNICATIONS PROTOCOL (READY FOR INTEGRATION WITH SYSTEMS SCADA)   DNP 3.0 YES
4.28 COMMUNICATION PORTS     YES
  ETHERNET   YES YES
  COMMUNICATION WITH PERSONAL COMPUTER   RS232, ETHERNET YES
  COMMUNICATION  READ DATA   RS232, ETHERNET, RS485 YES
4.29 OPTION be commanded remotely WITH RADIO MODEM OR GSM MODEM.   YES YES
  EFFORTS TO SAFE OPERATION.   YES YES
  INPUT AND OUTPUT NEEDED FOR THIS EFFECT.   YES YES
4.3 CONFIURATION  SOFTWARE      
  ENVIROMENT   WINDOWS YES
  SECURITY SYSTEM   WITH PASSWORD YES
  INFORMATION DISCHARGE   YES YES
  PROGRAMMING IN REMOTELY   YES YES
5 AUXILIAR ENERGY FEEDER SYSTEM     YES
  SYSTEM   SINGLE PHASE YES
  INCLUDE AUXILIAR TRANSFORMER FOR CONTROL BOX   YES YES
5.01 BATTERY      
  COUNTRY   TO INDICATE CHINA
  MANUFACTURER   TO INDICATE LEOCH
  TYPE   TO INDICATE LEAD ACID
  NOMINAL VOLTAGE   TO INDICATE 12VX2
  NUMBER OF UNIT OPERATING VOLTAGE TO FAILURES.   10 OR MORE 24
  MEASURING THE CONDITION OF THE BATTERY.   YES YES
  BATTERY LIFE IN FAILURE OF LACK OF VOLTAGE.   48 HOURS 48
  INCLUDED IN THE CABINET OF CONTROL   YES YES
5.02 SYSTEM OF CHARGE OF THE BATTERIES      
  COUNTRY   TO INDICATE CHINA
  MANUFACTURER   TO INDICATE BEJINAG
  AUXILIAR VOLTAGE   220 VAC YES
  SYSTEM   SINGLE PHASE YES
  COMPATIBLE WITH SPECIFIED BATTERIES   YES YES
  INCLUDED IN THE CABINET OF CONTROL   YES YES
         
         