12kv/24kv/33kv Indoor Metal-Clad Switchgear Distribution Panel

Product Details
Customization: Available
Certification: ISO9001
Shell Material: Stainless Steel
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500 RMB
Plant Area
1001~2000 square meters
  • 12kv/24kv/33kv Indoor Metal-Clad Switchgear Distribution Panel
  • 12kv/24kv/33kv Indoor Metal-Clad Switchgear Distribution Panel
  • 12kv/24kv/33kv Indoor Metal-Clad Switchgear Distribution Panel
  • 12kv/24kv/33kv Indoor Metal-Clad Switchgear Distribution Panel
Find Similar Products

Basic Info.

Model NO.
KYN
Installation
Removable
Structure
Cabinet
Current
AC
Transport Package
Wooden
Specification
12/24KV
Trademark
HEMG
Origin
China
Production Capacity
100000

Product Description

7.1 Table of Specifications for Transformation or Arrival Cell 10.5 kV
DESCRIPTION UNIT VALUE REQUIRED VALUE OFFERED
1 GENERAL CHARACTERISTICS OF THE SUBSTATION              
  Substations   Oropesa Huaro Urpipata Oropesa Huaro Urpipata
1.1 Nominal operating voltage kV 10.5 10.5 10   10.5 10
1.2 Altitude of Installation masl 3400 3400 1000   3400 1000
1.3 Nominal frequency   60 HZ 60 HZ
2 GENERAL DATA OF THE EQUIPMENT              
2.1 Name of manufacturer         SENDALL SENDALL SENDALL
2.2 Model (factory designation)         KYN28 KYN28 KYN28
2.3 Country of origin         CHINA CHINA CHINA
2.4 Construction and test standard   IEC 62271-200 IEC 62271-200
2.5 Category of continuity of service (per IEC 62271-200)   LSC2B LSC2B
2.6 Partition Classification (per IEC 62271-200)   PM  
2.7 Internal Arcing Classification (per IEC 62271-200)   IAC-AFLR IAC-AFLR
2.8 Installation   Interior Interior
2.9 Access   Frontal; appropriate for mounting on wall Frontal; 
2.1 Modular construction   Yes; extendible on either side Yes; extendible on either side
3 NOMINAL DATA AND CHARACTERISTICS   Oropesa Huaro Urpipata Oropesa Huaro Urpipata
3.1 Maximum service voltage of equipment kV 10.5 10.5 10 10.5 10.5 10
3.2 Network frequency kV 12 12 12 12 12 12
3.3 Rated current of main bars Hz 60 60
3.4 Short-time current (I''k) A 630 630 1000 630 630 1250
3.5 Short-circuit current kA 25 25 25 25 25 25
3.6 Duration of short-circuit sec 3 3
3.7 Initial crest current kAp 2,5 x I''k 2,5 x I''k
3.8 Extinguishing medium of the switch   Vacuum Vacuum
3.9 Degree of mechanical protection (External)   IP  4X IP  4X
3.1 Degree of mechanical protection (Internal)   IP 2X IP 2X
3.11 Auxiliary voltages              
  Control circuit Vcc 110 110
  Spring Load Motor Circuit Vcc 110 110
  Heating circuit Vca 220 220
  Lighting Circuit Vca 220 220
3.12 Test Voltages   Oropesa Huaro Urpipata Oropesa Huaro Urpipata
  BIL impulse (1.2 / 50 ms wave) kVp 125 125 95 125 125 125
  Power-frequency (1 min.) kVef 50 50 28 50 50 50
  Auxiliary circuits (1 min.) kVef 2 2
3.13 Main Bars              
  Material   Cu Cu
  Section mm2       640 640 640
3.14 Bypass Bars              
  Material   Cu cu cu cu
  Section mm2       250 250 250
3.15 System Grounding              
  Material   Cu Cu
3.16 Painting   RAL 7035 RAL 7035
3.17 Overall Dimensions              
  Width (maximum) mm       1000 1000 1000
  Depth (maximum) mm       1860 1860 1860
  Maximum height mm       2400 2400 2400
3.18 Indication of presence of voltage   Yes Yes
3.19 Earthing switch   Yes Yes
4 POWER SWITCH              
4.1 Manufacturer     SENDALL SENDALL SENDALL
4.2 Model         ZN63A ZN63A ZN63A
4.3 Country of origin         CHINA CHINA CHINA
4.4 Standard which corresponds to power switch   IEC 62271-100 IEC 62271-100
4.5 Extinction medium   Vacuum Vacuum
4.6 Type of use   Interior Interior
4.7 Execution type   Removable Removable
4.8 Type of operation   Tripolar Tripolar
4.9 Method of accumulation of operating energy   Springs Springs
4.1 Method of loading the springs   Motor y manual Motor y manual
4.11 Method of opening and closing   Manual - electric Manual - electric
4.12 Maximum number of operation cycles   O - 0,3 sec - CO - 15 sec - CO O - 0,3 sec - CO - 180 sec - CO
      Oropesa Huaro Urpipata Oropesa Huaro Urpipata
4.13 Nominal voltage kV 10.5 10.5 10 10.5 10.5 10
4.14 Nominal current A 630 630 1000 630 630 1250
4.15 Nominal frequency Hz 60 60
4.16 Permissible short-time current (Icc) (3 sec) kA 25 25 25 25 25 25
4.17 Dynamic current supported in short circuit kAp 2,5 x Icc 2,5 x Icc
4.18 Opening time ms 33.5..60 33.5..60
4.19 Arc time ms 10…15 10…15
4.2 Total time of cut ms 43.5..75 43.5..75
4.21 Close time ms 60…80 60…80
      Oropesa Huaro Urpipata Oropesa Huaro Urpipata
4.22 Power-frequency voltage (60 Hz - 1 min.) kV 50 50 28 50 50 28
4.23 Impulse withstand voltage kV 125 125 95 125 125 95
4.24 Starting motor power consumption W Indicate 300W
4.25 Rated motor power consumption W Indicate 100W
4.26 Power consumption of the opening coil W Indicate 100W
4.27 Power consumption of the low-voltage coil W Indicate 100W
4.28 Power consumption of the closing coil W Indicate 100W
4.29 Motor supply voltage Vcc 110 110
4.3 Counter of switching operations   Yes Yes
4.31 Auxiliary contacts   Yes Yes
5 CURRENT TRANSFORMERS              
5.1 Manufacturer         JIANGSU JIANGSU JIANGSU
5.2 Model         LZZBJ9 LZZBJ9 LZZBJ9
5.3 Country of origin         CHINA CHINA CHINA
5.4 Construction and test standard   IEC 60044-1 IEC 60044-1
5.5 Insulation type   Resin Resin
5.6 Installation   Interior Interior
5.7 Rated Voltage kV 10.5 10.5 10.5 10.5 10
5.8 Maximum service voltage kV          
5.9 Network frequency Hz 60 60
5.1 Short-time current (3 sec) kA   25 25 25 25
5.11 Dynamic current kAp 2,5 x Icc 2,5 x Icc
5.12 Number of Cores   2          
5.13 Test Voltages   Oropesa Huaro Urpipata Oropesa Huaro Urpipata
  BIL impulse (1,2/50 mseg.) kVp 125 125 95 125 125 95
  Power-frequency (1 min.) kVef 50 50 28 50 50 28
5.14 Measurement nucleus              
  Current in primary A 600-300 600-300 600-300 600-300
  Current in secondary A 1 1
  Prestación (considerar una holgura del 30%.) VA 5VA 5VA
  Precision class   0.2 0.2
5.15 Protection nucelus              
  Current in primary A 600-300 600-300 600-300 600-300
  Current in secondary A 1 1
  Accuracy class VA 5P20 5P20
  Benefit (consider a 30% slack.)   5VA 5VA
6 VOLTAGE TRANSFORMERS              
6.1 Manufacturer         JIANGSU JIANGSU JIANGSU
6.2 Model         JDZ JDZ JDZ
6.3 Country of origin         CHINA CHINA CHINA
6.4 Construction and test standard   IEC 60044-2 IEC 60044-2
6.5 Insulation type   Resin Resin
6.6 Installation   Interior Interior
6.7 Rated Voltage kV 10.5 10.5 10 10.5 10
6.8 Maximum service voltage kV 12 12
6.9 Network frequency   60 60
6.1 Cantidad de secundarios  Hz 2 2
6.11 Test Voltages   Oropesa Huaro Urpipata Oropesa Huaro Urpipata
  BIL impulse (1,2/50 mseg.) kVp 125 125 95 125 95
  Power-frequency (1 min.) kVef 50 50 28 50 50 28
6.12 Relation transformation              
  Voltage on the primary kV 10.5/√3 10.5/√3 10/√3 10.5/√3  
  Voltage on the secondary kV 0.10/√3:0.10/√3 0.10/√3:0.10/√3
6.13 Secondary of measurement              
  Benefit (consider a 30% slack.) VA 5VA 5VA
  Accuracy class % 0.2 0.2
6.14 Secondary of protection              
  Benefit (consider a 30% slack.) VA 5VA 5VA
  Accuracy class   3P 3P
  Voltage factor   1.2 1.2
7 MULTIFUNCTION METER   In accordance with table of specifications guaranteed SEL-734
8 MULTIFUNCTION RELAY   In accordance with table of specifications guaranteed SEL-751+
9.0 Grounding switch   Oropesa Urpipata Oropesa Oropesa Huaro Urpipata
  Short-circuit capacity   Yes Yes Yes Yes YES
  Short-time current (I''k) kA 25 25 25 25 25
  Duration of short-circuit sec 3 3 3 3 3 3
  Auxiliary contacts normally open units 4 4 4 4 4
  Auxiliary contacts normally closed units 4 4 4 4 4 4
  Mechanical lock   Yes Yes Yes Yes YES
  Interlocking   Yes Yes Yes Yes YES
  Operation   Manual Manual
Note: The most important components, such as the interruptor and switch must be of the same brand as the cabinet/panel.  



12kv/24kv/33kv Indoor Metal-Clad Switchgear Distribution Panel
12kv/24kv/33kv Indoor Metal-Clad Switchgear Distribution Panel
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier