20/25 Mva 46 / 6.3 Kv 60Hz 3phases 2windings Power Transformer with Dga on Line Monitor System and Protection of Bushing Oltc Winding Oil Temperature IEC61850

Product Details
Customization: Available
Application: Power
Phase: Three
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500 RMB
Plant Area
1001~2000 square meters
  • 20/25 Mva 46 / 6.3 Kv 60Hz 3phases 2windings Power Transformer with Dga on Line Monitor System and Protection of Bushing Oltc Winding Oil Temperature IEC61850
  • 20/25 Mva 46 / 6.3 Kv 60Hz 3phases 2windings Power Transformer with Dga on Line Monitor System and Protection of Bushing Oltc Winding Oil Temperature IEC61850
  • 20/25 Mva 46 / 6.3 Kv 60Hz 3phases 2windings Power Transformer with Dga on Line Monitor System and Protection of Bushing Oltc Winding Oil Temperature IEC61850
Find Similar Products

Basic Info.

Model NO.
TX
Core
Core-type Transformer
Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000
Usage
Single-phase Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
High Frequency
Transport Package
Wooden
Specification
132KV 40MVA
Trademark
HEMG
Origin
China
Production Capacity
10000

Product Description

SPECIFICATION    
     
2.4.1  TECHNICAL SPECIFICATION FOR STEP UP    
POWER TRANSFORMER 35/40MVA  STEP UP TRANSFORMER 35/40MVA  STEP UP TRANSFORMER
Sl. No.    Particulars    Factory Data Factory Data
1.0    GENERAL       
1.1    Name of Manufacturer      HEMG
1.2    Description        
 The specification refers to a Three Phase Oil    
immerged ONAN/ONAF Cooling according to VDE/IEC/DIN/BS Standard.    
2    Rated KVA    35000/40000 35000/40000
3    No Load Voltage Ratio    6.6/132KV 6.6/132KV
4    No. of Phase     HT -3 , LT - 3 HT -3 , LT - 3
5    Cooling     ONAN/ONAF  ONAN/ONAF
6    Installation     Outdoor Outdoor
7    Frequency     50 Hz 50 Hz
8    Winding connection and material     Star-Delta, Copper  Star-Delta, Copper
9    Vector Group     Ynd1 Ynd1
10   tap    
    - Range     +10% to -20% at HV side. +15% to -15% at HV side.
    - No. of steps/POS     24 Steps, 25 Position  24 Steps, 25 Position
    - Variation per step, %    1.25% 1.25%
11    Temperature rise, Deg. C       
    - Top oil     50 0C  50 ºC
    - Winding     55 0C 55 ºC
12    Total loss at rated voltage at principal tapping and rated    
frequency, kW    192.22 190.22
13    Component losses, kW       
    - No load loss at rated voltage at principal    
 tapping and rated frequency, kW    30 28
    - Load loss at rated current at principal tapping at 75 Deg. C 160(122 ONAN) 160(122 ONAN)
    - Auxiliary Loss    2.22 2.22
14    Impedance at rated current for principal tapping, %     11.35% 11.5%
15    No load current at rated voltage and frequency, Amps       
16    Full wave lightning impulse withstand kVp     650 HV/ 70   LV 650 HV/ 95 LV
17    Efficiency at 75 Deg. C at unity power factor, %       
    - At full load    99.6824 99.52%
    - At 75% load     99.6833 99.50%
    - At 50% laod    99.6852 99.45%
18    Regulation at full load       
    - At unit pf   4 4
    - At 0.8 lagging pf    10.01 10.01
19    Details of tap changer       
    - Make    Huaming China Huaming China
    - Type       
    - Range     +10% to -20% at HV Side. +15% to -15% at HV side.
20    No. of steps/Position     24/25 24/25
    a) Rated Voltage, kV     132 kV 72.5 kV
    b) Step Voltage, V     1.25% 1000-1500V
21    Terminal arrangement       
    - HV       Bushing 
    - LV       Bushing 
    - Neutral       Bushing 
22    Approximate masses, Kg       
    - Core & Windings     29300 31600
    - Tank, fittings & accessories     19200 12000
    - Oil     14500 12000
    - Total    63000 55600
23    Heaviest package, Kg    49050(WITH OIL) 50000(WITH OIL)
24    Overall dimensions      6260*4950*5380mm(L*W*H)
     
25  Auxiliary power voltage    
AC 3-phase, 220-240/415-440V, 50Hz 3-phase, 220-240/415-440V, 50Hz
  1-phase, 220-240Vac, 50Hz 1-phase, 220-240Vac, 50Hz
DC 110Vdc 110Vdc
     
FITTINGS & ACCESSORIES:    
     
The following fittings and accessories will be  YES YES
provided along with the main transformers.    
  YES YES
1Rating and diagram plate    
  YES YES
a) Two (2) Nos. safety earthing terminals for     
transformer tank and radiator banks YES YES
b)Lifting lugs    
  YES YES
c)Jacking pads    
  YES YES
d)Skids    
     
e)Pulling eyes    
  YES YES
f) Terminal marking plate    
     
g) Conservator (main chamber and OLTC chamber) with filling cap. drain YES YES
valve, vent pipe and equaliser connection.    
  YES YES
h)RTCC Panel    
     
i)Magnetic type oil level indicator with 150mm dia dial and alarm YES YES
initiating contacts for low and high oil levels.    
  YES YES
j) Explosion vent with double diaphragm    
  YES YES
k)Inspection cover    
  YES YES
l)Pressure relief device    
  YES YES
-    Air release devices    
     
-    De-hydrating breather complete with 1st fill of activated alumina or YES YES
silica gel    
     
-    150 mm dial type oil temperature indicator with alarm and trip YES YES
contacts and maximum reading pointer.    
     
-    150 mm dial type winding temperature indicator with alarm & trip YES YES
contacts and maximum reading pointer.    
     
-    Double float Buchholz relay with alarm and trip contacts, tests, YES YES
cocks and window to view the trapped gas.    
     
-    Oil drain valve at bottom. YES YES
     
-    Oil sampling valves at top, middle and bottom. YES YES
     
-    One (1) shut-off valve each, on either side of Buchholz relay. YES YES
     
-    Sampling gas collectors for Buchholz relay at accessible height. YES YES
     
-    Bank of radiators with isolating valves at top and bottom for    
connections between the transformer tank and radiator banks. YES YES
     
-    Plain oil level gauge. SIZE DESIGN AS PER US SIZE DESIGN AS PER US
     
-    Bi-directional flanged rollers suitable for 1676 mm gauge. 2000x1435 2000x1435
     
-    Weather proof marshalling box for housing dial type temperature    
indicators, terminal blocks etc. and complete with toughened glass    
window, space heater, internal illumination etc. The wiring from    
various accessories / fittings to marshalling box will be by 1.1 kV    
grade PVC insulated, sheathed and armoured copper conductor cable of    
size 2.5 sq.mm. Marshalling box shall be mounted on the transformer YES YES
tank and not on radiator banks.    
     
-    Climbing rungs or ladder. YES YES
     
X    HV neutral bushing    
  TERMINAL BOX SHOW WTI OTI TERMINAL BOX SHOW WTI OTI
-    WTI CT terminal box    
     
-    Earthing terminal with M12 tapped holes    
     
x    HV and LV cable boxes with bushings LT bushing up outline with flange,HT CANCEL LT bushing up outline with flange,HT CANCEL
     
-    On Load Tap Changer (OLTC) with oil surge relay, RTCC, AVR    
     
-    Oil filler pipe with cap for transformer conservator and OLTC    
Chamber (50 mm dia).    
CT    
HV CT: 200/1 , 15 VA, 5P 20 HV CT: 300/1 , 15 VA, 5P 20  1PC/PHASE HV CT: 100/1 , 15 VA, 5P 20  1PC/PHASE
     
HV Neutral CT: 200/1-1. (Two core) 15 VA 5P 20 for REF & SEF HV N CT: 300/1  15 VA 5P 20    1PC/PHASE HV N CT: 100/1  15 VA 5P 20    1PC/PHASE
     
LV CT : 2400/1,  15 VA, 5P20 LV CT : 4000/1,  15 VA, 5P20   1PC/PHASE LV CT : 1200/1,  15 VA, 5P20    1PC/PHASE
     
WTI CT: 1837/5 A (Depends on your WTI) WTI  CT: 300/5 A WTI  CT: 100/5 A
 20/25 Mva 46 / 6.3 Kv 60Hz 3phases 2windings Power Transformer with Dga on Line Monitor System and Protection of Bushing Oltc Winding Oil Temperature IEC61850
20/25 Mva 46 / 6.3 Kv 60Hz 3phases 2windings Power Transformer with Dga on Line Monitor System and Protection of Bushing Oltc Winding Oil Temperature IEC61850