27kv Pole Mounted Sectionalizer with Fault Monitoring System

Product Details
Customization: Available
Type: High-voltage
Structure: Double-column Disconnector
Still deciding? Get samples of US$ 5000/Piece
Request Sample
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500 RMB
Plant Area
1001~2000 square meters
  • 27kv Pole Mounted Sectionalizer with Fault Monitoring System
  • 27kv Pole Mounted Sectionalizer with Fault Monitoring System
Find Similar Products

Basic Info.

Model NO.
FDZ
Installation
Outdoor High-voltage
Operation
Manual
Grounding Mode
Grounding
Movement Mode
Vertical Rotary Type
Certification
ISO
Transport Package
Wooden
Specification
27KV
Trademark
HEMG
Origin
China
Production Capacity
50000

Product Description

27kv Pole Mounted Sectionalizer with Fault Monitoring System
27kv Pole Mounted Sectionalizer with Fault Monitoring System
  ITEM  1  : SECTIONALIZERS 1 POLE  15 KV PROGRAMMABLE      
ITEM SPECIFICATIONS UNIT REQUIRED GUARANTEED
1 GENERAL DATA      
1.01 COUNTRY OF ORIGIN.   INDICATE CHINA
1.02 MANUFACTURER   INDICATE HEMG
1.03 MODEL.   INDICATE FDK-15KV
1.04 STANDARD OF MANUFACTURE   ANSI C37.63 or IEC ANSI C37.63/IEC
1.05 TYPE      OUTDOOR OUTDOOR
1.06 SYSTEM   1 POLE ( SINGLE POLE) SINGLE POLE
1.07 TYPE OF OPERATION   AUTOMATYC AND MANUAL AUTOMATIC AND MANUAL
1.08 ALITUDE OF OPERATION MOSL FROM 500 TO 4500 UP TO 4500M
1.09 TYPE OF PERFORMANCE ACCORDING TO CONFIGURATION (1 POLE, TWO POLE OR 3 POLE)   AUTOMATYC AND MANUAL AUTOMATIC AND MANUAL
2 NOMINAL DATA BASE SUPPORT OF SECTIONALIZER      
2.01 NOMINAL FRECUENCY.   60 HZ 60HZ
2.02 VOLTAGE CHARACTERISTICS.      
  NOMINAL VOLTAGE OF THE SYSTEM. KV 10, 13.2, 13.8 10..13.2.13.8
  MAXIMUM VOLTAGE OF THE SYSTEM. KV 15 15
2.03 INSULATION LEVEL.      
  NOMINAL VOLTAGE   KV 15 15
  WITHSTAND VOLTAGE INDUSTRIAL FREQUENCY  1 MINUTE KVp 50 50
  WITHSTAND VOLTAGE IMPULSE 1.2/50 us KVp 125 125
  LEAKAGE DISTANCE MM/KV 25 25
2.04 CURRENT CHARACTERISTICS      
  NOMINAL CURRENT A 100 OR MORE 100A
  CURRENT OF NOMINAL SYMMETRICAL INTERRUPTION. KA 4 OR MORE 8
  PEAK VALUE OF FAULT CURRENT. KA 10 OR MORE 10
2.05 MANUFACTURE  CHARACTERISTICS.      
  ISOLATING MATERIAL.   PORCELAIN OR SILICON RUBBER PORCELAIN
  DRIVER SECTION RANGE. MM2 35 TO 120 35 TO 120MM2
  CABLE MATERIAL ADMISSIBLE.   Cu / Al CU/AL
3 SECTIONALIZER CHARACTERISTICS.      
  RANGE OF CURRENT ACTION. A FROM 5 TO 230 5A-230A
  STEP CURRENT GRADUATION. A 1 1A
  PRE-LOAD CURRENT (ATTACH PRE-LOAD CURVE). A 0.5 OR LESS 0.3A
  NUMBER OF OPENING COUNTINGS.   1, 2, 3 AND 4 1, 2, 3 AND 4
  CURRENT BLOCKING OF INRUSH.   YES  
  DETECTION OF DEADLINE. mamp 300 OR LESS 300mA
  DEADLINE VERIFICATION TIME. msecond 100 or less 100mS
  MAXIMUM MEMORY TIME WITH DEADLINE. s between 30 and 300 30s-300s
  TOTAL OPENING TIME. s 0.5 or less 0.5S
  MEMORY RESET TIME (ACCOUNTS). s from 10 to 80 in steps og 1 sec from 10 to 80 in steps of 1 sec
  ADMISSIBLE CURRENT OF SHORT DURATION.      
  1 sec KA 10 10
  2 sec. KA 4 4
3.11 PEAK CURRENT VALUE ADMISSIBLE. KA 16 16
3.12 PREPARED FOR DISTANCE ACCESS WITH DNP PROTOCOL.     YES
3.13 PORT OF COMMUNICATION (FOR THE CONCENTRATOR).      
3.14 COMMUNICATION PROTOCOL.     IEC60870-5-101
3.15 SOFTWARE AND ACCESSORIES FOR COMMUNICATION AND CONFIGURATION OF THE SECTIONALIZER THROUGH LAPTOP (FUNCTIONAL PARAMETERS AND STATISTICAL CONSULTATION STORED)     YES
3.16 THE UNIT OF THE INTERFACE TOOL MUST BE CONSIDERED FOR EVERY 50 UNITS OF SECTIONALIZERS.     YES
         
         
  ITEM  2  : SECTIONALIZERS 1 POLE  27 KV PROGRAMMABLE      
ITEM SPECIFICATIONS UNIT REQUIRED GUARANTEED
1 GENERAL DATA      
1.01 COUNTRY OF ORIGIN.   INDICATE CHINA
1.02 MANUFACTURER   INDICATE HEMG
1.03 MODEL.   INDICATE FDK-27KV
1.04 STANDARD OF MANUFACTURE   ANSI C37.63 or IEC ANSI C37.63 /IEC
1.05 TYPE      OUTDOOR OUTDOOR
1.06 SYSTEM   1 POLE ( SINGLE POLE) SINGLE POLE
1.07 TYPE OF OPERATION   AUTOMATYC AND MANUAL AUTOMATIC AND MANUAL
1.08 ALITUDE OF OPERATION MOSL FROM 500 TO 4500 UP TO 4500
1.09 TYPE OF PERFORMANCE ACCORDING TO CONFIGURATION (1 POLE, TWO POLE OR 3 POLE)   AUTOMATYC AND MANUAL AUTOMATIC AND MANUAL
2 NOMINAL DATA BASE SUPPORT OF SECTIONALIZER      
2.01 NOMINAL FRECUENCY.   60 HZ 60HZ
2.02 VOLTAGE CHARACTERISTICS.      
  NOMINAL VOLTAGE OF THE SYSTEM. KV 22.9 22.9
  MAXIMUM VOLTAGE OF THE SYSTEM. KV 27 27
2.03   INSULATION LEVEL.      
  NOMINAL VOLTAGE   KV 227 27
  WITHSTAND VOLTAGE INDUSTRIAL FREQUENCY  1 MINUTE KVp 60 60
  WITHSTAND VOLTAGE IMPULSE 1.2/50 us KVp 150 50
  LEAKAGE DISTANCE MM/KV 25 25
2.04 CURRENT CHARACTERISTICS      
  NOMINAL CURRENT A 100 OR MORE 100
  CURRENT OF NOMINAL SYMMETRICAL INTERRUPTION. KA 4 OR MORE 4
  PEAK VALUE OF FAULT CURRENT. KA 10 OR MORE 10
2.05 MANUFACTURE  CHARACTERISTICS.      
  ISOLATING MATERIAL.   PORCELAIN OR SILICON RUBBER PROCELAIN
  DRIVER SECTION RANGE. MM2 35 TO 120 35-120MM2
  CABLE MATERIAL ADMISSIBLE.   Cu / Al CU/AL
3 SECTIONALIZER CHARACTERISTICS.      
  RANGE OF CURRENT ACTION. A FROM 5 TO 230 FROM 5 TO 230A
  STEP CURRENT GRADUATION. A 1 1
  PRE-LOAD CURRENT (ATTACH PRE-LOAD CURVE). A 0.5 OR LESS 0.3
  NUMBER OF OPENING COUNTINGS.   1, 2, 3 AND 4 1,2,3,4
  CURRENT BLOCKING OF INRUSH.   YES YES
  DETECTION OF DEADLINE. mamp 300 OR LESS 300
  DEADLINE VERIFICATION TIME. msecond 100 or less 100
  MAXIMUM MEMORY TIME WITH DEADLINE. s between 30 and 300 30-300
  TOTAL OPENING TIME. s 0.5 or less 0.5
  MEMORY RESET TIME (ACCOUNTS). s from 10 to 80 in steps oF 1 sec FROM 10 TO 80 IN STEPS OF 1 SEC
  ADMISSIBLE CURRENT OF SHORT DURATION.      
  1 sec KA 8 8
  2 sec. KA 3 3
3.11 PEAK CURRENT VALUE ADMISSIBLE. KA 20 20
3.12 PREPARED FOR DISTANCE ACCESS WITH DNP PROTOCOL.   YES YES
3.13 PORT OF COMMUNICATION (FOR THE CONCENTRATOR).   RS-485 OR ETHERNET RS-485
3.14 COMMUNICATION PROTOCOL.   IEC 60870-5-101 ( IEC104) OR DNP IEC 60870-5-101
3.15 SOFTWARE AND ACCESSORIES FOR COMMUNICATION AND CONFIGURATION OF THE SECTIONALIZER THROUGH LAPTOP (FUNCTIONAL PARAMETERS AND STATISTICAL CONSULTATION STORED)   YES YES
3.16 THE UNIT OF THE INTERFACE TOOL MUST BE CONSIDERED FOR EVERY 50 UNITS OF SECTIONALIZERS.   YES YES
         
          
         
         
  ITEM 3  :  DATA CONCENTRATOR FOR PROGRAMMABLE SECTIONALIZERS 15 KV AND 27 KV, BIL 150 KV      
ITEM SPECIFICATIONS UNIT REQUIRED GUARANTEED
1 CONCENTRATOR      
  MANUFACTURER.   INDICATE HEMG
  COUNTRY   INDICATE CHINA
  MODEL.   INDICATE APT-309
  DISTANCE OF COMMUNICATION VIA RADIO FRECEUNCIA FOR THE COLLECTION OF EVENTS (PERMANENT FAILURES, TEMPORARY FAILURES) FOR THE SECTIONALIZERS NEAR THE CONCENTRATOR.   50 MTS OR MORE 50MTS
  NUMBER OF AIR CIRCULAR SECTIONALISTS FOR RADIO COMMUNICATION WITH THE CONCENTRATOR.   9 OR MORE 9
  COMMUNICATION BETWEEN THE CONCENTRATOR AND THE MANAGEMENT SOFTWARE (FOR CONFIGURATION AND MODIFICATION OF PARAMETERS).   YES YES
  COMMUNICATION BETWEEN THE CONCENTRATOR AND A SCADA SYSTEM (WITHOUT INTERMEDIATE SOFTWARE) THROUGH DNP3 COMMUNICATION PROTOCOL ON TCP / IP, USING GPRS COMMUNICATION INTERFACE THE ANTENNA MUST BE EXTERNAL OMNIDIRETIONAL, TYPE BOND WITH COAXIAL CABLE AND BNC / SMA CONNECTOR OR SIMILAR WITH GAIN OF 14 DBI OR MORE.   YES BY IE80670-5-101.104/DNP IS ARAIABLE ,PRICE WILL BE EXTRA ADDING
  EMBOSSED GPRS MODEM.   YES YES
  INTERNAL POWER SUPPLY BATTERY (MAINTENANCE FREE AND REPLACEABLE).   5 YEARS OR MORE 5
  WITH MEMORY TO STORE LAST FAILURES, EVENTS AND DOWNLOAD THE INFORMATION OF THE SAME EQUIPMENT).   YES YES
  TYPE OF FAILURE WITH TIME STAMP, CURRENT MEASURES, PRESENCE / ABSENCE OF VOLTAGE OF THE BATTERY, PARAMETERS OF THE MANAGED EQUIPMENT AND STATE OF THE SAME CONCENTRATOR.   YES YES
  THE INFORMATION STORED IN THE CONCENTRATOR CAN BE MANAGED FROM THE MANAGEMENT SOFTWARE IN A LOCAL AND REMOTE WAY.   YES YES
  PORT  RJ45 10/100 FOR LOCAL CONFIGURATION   YES YES
2 SOFTWARE FOR CONFIGURATION AND MANAGEMENT OF THE CONCENTRATOR AND SECTIONALIZER.      
  MANUFACTURER.   INDICATE HEMG
  COUNTRY   INDICATE CHINA
  MODEL.      
  NAME OF THE SOFTWARE.   INDICATE FAULT MONITORIG SOFTWARE
  EXECUTION UNDER WINDOWS OPERATING SYSTEM.   YES YES
  DIRECT CONNECTION INTERFACE TO THE EQUIPMENT.   YES YES
  HANDLING OF USERS, LEVELS AND ACCESS PERMITS.   YES YES
  MANUFACTURING AND CONFIGURATION MODULE.   YES YES
  PARAMETERIZATION MODULE OF THE CONCENTRATOR.   YES YES
  EVENTS DISPLAY MODULE.   YES YES
  MODULE OF HISTORICAL AND STATISTICAL REPORT.   YES YES
  EXPORT OF REPORTS TO A CALCULATION SHEET FORMAT.   YES YES
         