• 22.9kv Outdoor Pole Mounted Oil Insulating Combine Current and Voltage Transfoemer
  • 22.9kv Outdoor Pole Mounted Oil Insulating Combine Current and Voltage Transfoemer
  • 22.9kv Outdoor Pole Mounted Oil Insulating Combine Current and Voltage Transfoemer

22.9kv Outdoor Pole Mounted Oil Insulating Combine Current and Voltage Transfoemer

Application: Instrument
Type: Combined Transformer
Phase: Three
Operation Condition: Outdoor
Usage: Measurement
Winding Form: Multilayer Honeycomb Type
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
JLS
Insulating Medium
Insulating Oil
Installation
Extension Type
Transport Package
Wooden Case
Specification
11KV 2CT 2VT
Trademark
HEMG
Origin
China

Product Description

22.9kv Outdoor Pole Mounted Oil Insulating Combine Current and Voltage Transfoemer
Bitmap
 1.4 Combined Voltage and Current Transformer of 12 / 5 A and 22900 V3/100V3, 3TC class 0.2S and 3 TT class 0.2.
 
 
SPECIFICATION UNIT REQUIRED GUARANTEED
   
  VOLTAGE COILS      
1 QTY OF COILS   3 3
2 POWER VA 15 15
3 Nominal voltage in the primary. V 22900:V3 22900:V3
4 Nominal voltage in the secondary. V 100:V3 100:V3
5 Precision.   0.2 0.2
  Winding of Current.      
6 Qty  of coils EACH 3 3
7 Power. VA 15 15
8 Nominal current in the primary. A 12A 12A
9 Nominal current in the Secondary. A 5 5
10 Precision.   0.2S (EXENTED RATIO) 0.2S (EXENTED RATIO)
11 Altitude of Installation.  msnm 4500 4500
12 System frequency. Hz 60 60
13 Mounting.   outdoor outdoor
14 Connection type.   Delta Delta
15 Application   measure measure
16 Number of phases   3 3
17 Cooling type   ONAN ONAN
18 Interior insulation level on the AT side kV 24/50/125 24/50/125
19 Interior insulation level on the BT side kV 0.72/3 0.72/3
20 Position and type of insulators   Over the cover, porcelain bushing  Over the cover, porcelain bushing 
21 Number of Isolators in MT:      
          Delta each 6 6
22 Minimum exterior BIL kV 200 200
23 Minimum leakage line mm 845 845
24 Type of service   Continue Continue
  Minimum values of insulation:      
25 From AT-BT  M 10 000  10 000 
26 AT-Mass 10 000 10 000
27 BT-Mass 1 000 1 000
28 Losses in current, voltage and total transformers  W 20 20
29 Oil filling tube with built-in stopper that allows the impermeability of the dielectric oil with the environment.   yes yes
30 Terminal for connection of earth in the tank of the transformer, being the pin of stainless steel.   yes yes
31   Lifting ears.   yes yes
  Dielectric oil with the following characteristics:   yes yes
32 Mineral oil.   yes yes
33 Discharge voltage not less than 45 kV according to ASTM D - 1816.   yes yes
34 Exempt from PCB.   yes yes
35 Faucet for emptying and extraction of oil samples with gradual opening.   yes yes
36 Device for fixing in pole (suspension handles and clamps), must include clamps with their respective 5/8 "x 6" bolts and washers.   yes yes
37 Bronze over pressure valve of 50 kPa.   yes yes
38 Bases with "U" profiles for anchoring.   yes yes
39 Indication in low or high relief of the relative polarity of the windings.   yes yes
40 Metal box of terminals in low voltage with bolted cover (with IP 66 grade) and security key with the option of placing a security seal. Additionally it must include 01 padlock per team, eyelets for the padlock installation and its respective protector, both soldiers to the cover.   yes yes
41 The tank, the lid, the clamps, among others, should be painted with epoxy zinc-chromate base paint and finished with epoxy enamel with a thickness greater than 150 microns. For the interior of the tank, it should only be painted with the base paint.   yes yes
42 Pickling of the tank and lid should be with a system sandblasting in high pressure.   yes yes
43 The tank must be manufactured with cold rolled steel sheet with a thickness of not less than 2 mm.   yes yes
44 They must include all the necessary protections to provide a quality product.   yes yes
  Type of terminal board and / or terminal board.   yes yes
45 Connection scheme.      
46 Output terminals in the voltage and current circuits.   yes yes
47 Disconnector or terminal blocks or short circuitable Ritz type for the current circuit.   yes yes
48 Protection of the voltage circuit (Thermo magnetic switch).   yes yes
49 Antiferroronantes resistors.   Not Not
50 Installation Manual and testing protocol of the manufacturer attached to the equipment.   Yes Yes
51 8 "diameter brackets for MT 13/300 posts with 5 / 8x6" bolts with 2 flat washers and one pressure washer, both of which should be hot galvanized steel.   Yes Yes
         
Bitmap
 
       
 1.5 Combined Voltage and Current Transformer of 40-20 / 5 A and 22900 V3/100V3, 3TC class 0.2S and 3 TT class 0.2.  
 
SPECIFICATION UNIT REQUIRED GUARANTEED
   
  VOLTAGE COILS      
1 QTY OF COILS   3 3
2 POWER VA 15 15
3 Nominal voltage in the primary. V 22900:V3 22900:V3
4 Nominal voltage in the secondary. V 100:V3 100:V3
5 Precision.   0.2 0.2
  Winding of Current.      
6 Qty  of coils EACH 3 3
7 Power. VA 15 15
8 Nominal current in the primary. A 40 to 20 40 to 20
9 Nominal current in the Secondary. A 5 5
10 Precision.   0.2S (EXENTED RATIO) 0.2S (EXENTED RATIO)
11 Altitude of Installation.  msnm 4500 4500
12 System frequency. Hz 60 60
13 Mounting.   outdoor outdoor
14 Connection type.   Delta Delta
15 Application   measure measure
16 Number of phases   3 3
17 Cooling type   ONAN ONAN
18 Interior insulation level on the AT side kV 24/50/125 24/50/125
19 Interior insulation level on the BT side kV 0.72/3 0.72/3
20 Position and type of insulators   Over the cover, porcelain bushing  Over the cover, porcelain bushing 
21 Number of Isolators in MT:      
          Delta each 6 6
22 Minimum exterior BIL kV 200 200
23 Minimum leakage line mm 845 845
24 Type of service   Continue Continue
  Minimum values of insulation:      
25 From AT-BT  M 10 000  10 000 
26 AT-Mass 10 000 10 000
27 BT-Mass 1 000 1 000
28 Losses in current, voltage and total transformers  W 20 20
29 Oil filling tube with built-in stopper that allows the impermeability of the dielectric oil with the environment.   yes yes
30 Terminal for connection of earth in the tank of the transformer, being the pin of stainless steel.   yes yes
31   Lifting ears.   yes yes
  Dielectric oil with the following characteristics:   yes yes
32 Mineral oil.   yes yes
33 Discharge voltage not less than 45 kV according to ASTM D - 1816.   yes yes
34 Exempt from PCB.   yes yes
35 Faucet for emptying and extraction of oil samples with gradual opening.   yes yes
36 Device for fixing in pole (suspension handles and clamps), must include clamps with their respective 5/8 "x 6" bolts and washers.   yes yes
37 Bronze over pressure valve of 50 kPa.   yes yes
38 Bases with "U" profiles for anchoring.   yes yes
39 Indication in low or high relief of the relative polarity of the windings.   yes yes
40 Metal box of terminals in low voltage with bolted cover (with IP 66 grade) and security key with the option of placing a security seal. Additionally it must include 01 padlock per team, eyelets for the padlock installation and its respective protector, both soldiers to the cover.   yes yes
41 The tank, the lid, the clamps, among others, should be painted with epoxy zinc-chromate base paint and finished with epoxy enamel with a thickness greater than 150 microns. For the interior of the tank, it should only be painted with the base paint.   yes yes
42 Pickling of the tank and lid should be with a system sandblasting in high pressure.   yes yes
43 The tank must be manufactured with cold rolled steel sheet with a thickness of not less than 2 mm.   yes yes
44 They must include all the necessary protections to provide a quality product.   yes yes
  Type of terminal board and / or terminal board.   yes yes
45 Connection scheme.      
46 Output terminals in the voltage and current circuits.   yes yes
47 Disconnector or terminal blocks or short circuitable Ritz type for the current circuit.   yes yes
48 Protection of the voltage circuit (Thermo magnetic switch).   yes yes
49 Antiferroronantes resistors.   Not Not
50 Installation Manual and testing protocol of the manufacturer attached to the equipment.   Yes Yes
51 8 "diameter brackets for MT 13/300 posts with 5 / 8x6" bolts with 2 flat washers and one pressure washer, both of which should be hot galvanized steel.   Yes Yes
         
Bitmap
 
       
 1.6  Combined Voltage and Current Transformer of 80 - 40 / 5 A and 22900 V3/100V3, 3TC class 0.2S and 3 TT class 0.2.  
 
SPECIFICATION UNIT REQUIRED GUARANTEED
   
  VOLTAGE COILS      
1 QTY OF COILS   3 3
2 POWER VA 15 15
3 Nominal voltage in the primary. V 22900:V3 22900:V3
4 Nominal voltage in the secondary. V 100:V3 100:V3
5 Precision.   0.2 0.2
  Winding of Current.      
6 Qty  of coils EACH 3 3
7 Power. VA 15 15
8 Nominal current in the primary. A 80 TO 40 80 TO 40
9 Nominal current in the Secondary. A 5 5
10 Precision.   0.2S (EXENTED RATIO) 0.2S (EXENTED RATIO)
11 Altitude of Installation.  msnm 4500 4500
12 System frequency. Hz 60 60
13 Mounting.   outdoor outdoor
14 Connection type.   Delta Delta
15 Application   measure measure
16 Number of phases   3 3
17 Cooling type   ONAN ONAN
18 Interior insulation level on the AT side kV 24/50/125 24/50/125
19 Interior insulation level on the BT side kV 0.72/3 0.72/3
20 Position and type of insulators   Over the cover, porcelain bushing  Over the cover, porcelain bushing 
21 Number of Isolators in MT:      
          Delta each 6 6
22 Minimum exterior BIL kV 200 200
23 Minimum leakage line mm 845 845
24 Type of service   Continue Continue
  Minimum values of insulation:      
25 From AT-BT  M 10 000  10 000 
26 AT-Mass 10 000 10 000
27 BT-Mass 1 000 1 000
28 Losses in current, voltage and total transformers  W 20 20
29 Oil filling tube with built-in stopper that allows the impermeability of the dielectric oil with the environment.   yes yes
30 Terminal for connection of earth in the tank of the transformer, being the pin of stainless steel.   yes yes
31   Lifting ears.   yes yes
  Dielectric oil with the following characteristics:   yes yes
32 Mineral oil.   yes yes
33 Discharge voltage not less than 45 kV according to ASTM D - 1816.   yes yes
34 Exempt from PCB.   yes yes
35 Faucet for emptying and extraction of oil samples with gradual opening.   yes yes
36 Device for fixing in pole (suspension handles and clamps), must include clamps with their respective 5/8 "x 6" bolts and washers.   yes yes
37 Bronze over pressure valve of 50 kPa.   yes yes
38 Bases with "U" profiles for anchoring.   yes yes
39 Indication in low or high relief of the relative polarity of the windings.   yes yes
40 Metal box of terminals in low voltage with bolted cover (with IP 66 grade) and security key with the option of placing a security seal. Additionally it must include 01 padlock per team, eyelets for the padlock installation and its respective protector, both soldiers to the cover.   yes yes
41 The tank, the lid, the clamps, among others, should be painted with epoxy zinc-chromate base paint and finished with epoxy enamel with a thickness greater than 150 microns. For the interior of the tank, it should only be painted with the base paint.   yes yes
42 Pickling of the tank and lid should be with a system sandblasting in high pressure.   yes yes
43 The tank must be manufactured with cold rolled steel sheet with a thickness of not less than 2 mm.   yes yes
44 They must include all the necessary protections to provide a quality product.   yes yes
  Type of terminal board and / or terminal board.   yes yes
45 Connection scheme.      
46 Output terminals in the voltage and current circuits.   yes yes
47 Disconnector or terminal blocks or short circuitable Ritz type for the current circuit.   yes yes
48 Protection of the voltage circuit (Thermo magnetic switch).   yes yes
49 Antiferroronantes resistors.   Not Not
50 Installation Manual and testing protocol of the manufacturer attached to the equipment.   Yes Yes
51 8 "diameter brackets for MT 13/300 posts with 5 / 8x6" bolts with 2 flat washers and one pressure washer, both of which should be hot galvanized steel.   Yes Yes

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now