ÍTEM | DESCRIPCIÓN | DESCRIPTION | ABREVIATION | UNIT | REQUIRED | OFFER |
1 | Fabricante | Manufacturer | HEMG | |||
2 | País | Origin | CHINA | |||
3 | Referencia | Reference | T20181123 | |||
4 | Puesta a tierra | Earthing blade | Disconnector without earthing blade | Disconnector without earthing blade | ||
5 | Norma de Fabricación | International Standard | IEC 62271-102 | IEC62271 | ||
6 | Norma de Calidad | Quality Standard | ISO 9001 | ISO9001 | ||
7 | Instalación | Installation | Outdoor | OUTDOOR | ||
8 | Montaje | Assembly | center break or Vertical | VERTICAL BREAK | ||
9 | Altura de instalación | Installation height | msnm | <=1000 | 1000 | |
13 | Grado de protección | Degrees of protection provided by enclosures | IP54 | IP54 | ||
14 | Tensión máxima | Rated Voltage | Ur | kV | 24 | 24 |
15 | Tensión asignada soportada a la frecuencia industrial | Rated short-duration power frequency withstand voltage | Ud | |||
a) A tierra y entre polos | a) Ground to phase | kV | 50 | 50 | ||
b) A través de la distancia de seccionamiento | b) Across isolating distance | kV | Supplier | 65 | ||
16 | Tensión asignada soportada al impulso tipo rayo | Rated lightning impulse withstand voltage | Up | |||
a) A tierra y entre polos | a) Ground to phase | kV | 145 | 145 | ||
b) A través de la distancia de seccionamiento | b) Across isolating distance | kV | Supplier | 160 | ||
17 | Frecuencia asignada | Rated Frequency | fr | Hz | 50 | 50 |
18 | Corriente asignada normal | Rated normal current | Ir | A | 7500 | 8000 |
19 | Corriente de corta duración admisible asignada | Short - time withstand current | Ik | kA | 40 | 40 |
20 | Duración del cortocircuito asignada | Rated duration of short circuit | tk | s | 1 | 1 |
21 | Distancia de fuga fase a tierra | Creepage distance phase to earth | mm/kV | 53.7 | 53.7 | |
22 | Distancia de fuga fase a fase | Creepage distance phase to phase | mm/kV | 31 | 31 | |
23 | ¿Se requiere corrección por altura por parte del fabricante? | Is it necessary to correct creepage distance for height by manufacturer? | No | NO | ||
24 | Distancia mínima de fuga corregida por altura | Corrected for altitude - Creepage distance | mm | 744 | 744 | |
25 | Desempeño mecánico | Mechanical Endurance | Class | M1 | M1 | |
26 | Endurance | Electrical Endurance | Class | No apply | NO APPLY | |
27 | Mecanismo de operación | Operation mechanism | Manual and motor | MANUAL AND MOTOR | ||
Datos del motor del mecanismo de operación (Um) | Operation mechanism data | |||||
a) Tipo | a) Type | CJ6A | ||||
b) Tensión | b) Voltage | Vcc | 125 | 125 | ||
c) Potencia | c) Power operation | W | 550 | |||
28 | d) Margen de tensión de operación | d) Dependent Power operation | % | 85-110 | 85-110 | |
29 | ||||||
Contactos auxiliares de reserva | Spare Auxiliary contacts | |||||
a) Número normalmente cerrados | a) Number of close contacts | >=6 | 8 | |||
b) Número normalmente abiertos | b) Number of open contacts | >=6 | 8 | |||
30 | c) Clase de contactos | c) Class of contacts | Supplier | COPPER WITH SILIVER | ||
31 | Tipo de accionamiento | Drive type | Three-pole | THREE POLE | ||
32 | Masa total para el transporte | Mass | 320KG | |||
33 | Volumen total para transporte | Volume | 0.67CBM | |||
34 | Dimensiones para transporte | Dimensions for transport | 1400mmX600mmX800mm | |||
Fuerzas estáticas admisibles en bornes | Static mechanical terminal loads | |||||
a) Longitudinal | a) Straight Load | N | 2500 | 2500 | ||
b) Transversal | b) Cross Load | Supplier | 2500 | |||
35 | c) Vertical | c) Vertical force | Supplier | 2500 | ||
36 | Carga dinámica admisible en terminales | Dinamic load in terminal | N | 2500 | 2500 | |
Datos sísmicos | Seismic information | |||||
a) Cumplimiento de la norma ETG A.20 | a) According to ETG A.20 | Si | SI | |||
37 | b) Frecuencia natural de vibración | b) Natural frequency of vibration | Hz | 9.23 | ||
38 | c) Coeficiente de amortiguamiento crítico | c) Damping coefficient | % | NO APPLY | ||
39 | Presencia de materiales corrosivos | Corrosive materials | No | NO | ||
40 | Garantía | Warranty | 3 years after commisioning | 3 YEARS AFTER COMMISIONING | ||
ÍTEM | DESCRIPCIÓN | DESCRIPTION | ABREVIATION | UNIT | REQUIRED | OFFER |
1 | Fabricante | Manufacturer | HEMG | |||
2 | País | Origin | CHINA | |||
3 | Referencia | Reference | T20181123 | |||
4 | Puesta a tierra | Earthing blade | Disconnector without earthing blade | Disconnector without earthing blade | ||
5 | Norma de Fabricación | International Standard | IEC 62271-102 | IEC62271 | ||
6 | Norma de Calidad | Quality Standard | ISO 9001 | ISO9001 | ||
7 | Instalación | Installation | Outdoor | OUTDOOR | ||
8 | Montaje | Assembly | center break or Vertical | VERTICAL BREAK | ||
9 | Altura de instalación | Installation height | msnm | <=1000 | 1000 | |
13 | Grado de protección | Degrees of protection provided by enclosures | IP54 | IP54 | ||
14 | Tensión máxima | Rated Voltage | Ur | kV | 24 | 24 |
15 | Tensión asignada soportada a la frecuencia industrial | Rated short-duration power frequency withstand voltage | Ud | |||
a) A tierra y entre polos | a) Ground to phase | kV | 50 | 50 | ||
b) A través de la distancia de seccionamiento | b) Across isolating distance | kV | Supplier | 65 | ||
16 | Tensión asignada soportada al impulso tipo rayo | Rated lightning impulse withstand voltage | Up | |||
a) A tierra y entre polos | a) Ground to phase | kV | 145 | 145 | ||
b) A través de la distancia de seccionamiento | b) Across isolating distance | kV | Supplier | 160 | ||
17 | Frecuencia asignada | Rated Frequency | fr | Hz | 50 | 50 |
18 | Corriente asignada normal | Rated normal current | Ir | A | 7500 | 8000 |
19 | Corriente de corta duración admisible asignada | Short - time withstand current | Ik | kA | 40 | 40 |
20 | Duración del cortocircuito asignada | Rated duration of short circuit | tk | s | 1 | 1 |
21 | Distancia de fuga fase a tierra | Creepage distance phase to earth | mm/kV | 53.7 | 53.7 | |
22 | Distancia de fuga fase a fase | Creepage distance phase to phase | mm/kV | 31 | 31 | |
23 | ¿Se requiere corrección por altura por parte del fabricante? | Is it necessary to correct creepage distance for height by manufacturer? | No | NO | ||
24 | Distancia mínima de fuga corregida por altura | Corrected for altitude - Creepage distance | mm | 744 | 744 | |
25 | Desempeño mecánico | Mechanical Endurance | Class | M1 | M1 | |
26 | Endurance | Electrical Endurance | Class | No apply | NO APPLY | |
27 | Mecanismo de operación | Operation mechanism | Manual and motor | MANUAL AND MOTOR | ||
Datos del motor del mecanismo de operación (Um) | Operation mechanism data | |||||
a) Tipo | a) Type | CJ6A | ||||
b) Tensión | b) Voltage | Vcc | 125 | 125 | ||
c) Potencia | c) Power operation | W | 550 | |||
28 | d) Margen de tensión de operación | d) Dependent Power operation | % | 85-110 | 85-110 | |
29 | ||||||
Contactos auxiliares de reserva | Spare Auxiliary contacts | |||||
a) Número normalmente cerrados | a) Number of close contacts | >=6 | 8 | |||
b) Número normalmente abiertos | b) Number of open contacts | >=6 | 8 | |||
30 | c) Clase de contactos | c) Class of contacts | Supplier | COPPER WITH SILIVER | ||
31 | Tipo de accionamiento | Drive type | Three-pole | THREE POLE | ||
32 | Masa total para el transporte | Mass | 320KG | |||
33 | Volumen total para transporte | Volume | 0.67CBM | |||
34 | Dimensiones para transporte | Dimensions for transport | 1400mmX600mmX800mm | |||
Fuerzas estáticas admisibles en bornes | Static mechanical terminal loads | |||||
a) Longitudinal | a) Straight Load | N | 2500 | 2500 | ||
b) Transversal | b) Cross Load | Supplier | 2500 | |||
35 | c) Vertical | c) Vertical force | Supplier | 2500 | ||
36 | Carga dinámica admisible en terminales | Dinamic load in terminal | N | 2500 | 2500 | |
Datos sísmicos | Seismic information | |||||
a) Cumplimiento de la norma ETG A.20 | a) According to ETG A.20 | Si | SI | |||
37 | b) Frecuencia natural de vibración | b) Natural frequency of vibration | Hz | 9.23 | ||
38 | c) Coeficiente de amortiguamiento crítico | c) Damping coefficient | % | NO APPLY | ||
39 | Presencia de materiales corrosivos | Corrosive materials | No | NO | ||
40 | Garantía | Warranty | 3 years after commisioning | 3 YEARS AFTER COMMISIONING | ||