720V Busbar Type Current Transformer

Product Details
Customization: Available
Application: Electronic, Instrument
Type: Current Transformer
Still deciding? Get samples of US$ 5/Piece
Request Sample
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500 RMB
Plant Area
1001~2000 square meters
  • 720V Busbar Type Current Transformer
  • 720V Busbar Type Current Transformer
  • 720V Busbar Type Current Transformer
Find Similar Products

Basic Info.

Model NO.
LMZ(J)1-0.5A
Operation Condition
Indoor
Usage
Protection, Measurement
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Epoxy Resin
Installation
Busbar Type
Transport Package
Carton with Wooden
Specification
720V 0.2CLASS 0.5CLASS
Trademark
HEMG
Origin
China
Production Capacity
100000

Product Description


LMZ(J)1-0.5A

LMZ(J)1-0.5A TYPE CURRENT  TRANSFORMER
 
720V Busbar Type Current Transformer
 
 
 
LMZ(J)1-0.5A
LMZ(J)1-0.5A Type Current Transformer
 
,
LMZ(J)1-0.5A,0.66kV,50Hz60Hz,.,,.,,,.
 
I.             Description
This current transformer is indoor busbar-type, it's used for current power measurement in A.C. power line with rated voltage 0.66kV and below, rated frequency 50Hz or 60Hz. It cast the current ratio on the surface of this CT to prevent the electricity theft due to changing the through core turns. Furthermore, the secondary outlet is housed with sealed covert and fixed screw with lead sealed holes, after sealing, it will prevent the electricity theft due to change of secondary connection.
 
,
II.          Technical Parameter
1,      The performance complies with the following:
GB20840.2
GB20840.2 Current Transformer supplement technical requirement
DL/T 448-2000
DL/T 448-2000  Electric Energy Metering Device Technical Management Specification
JJG 313-1994
JJG 313-1994 Current Transformer Inspection Specification
2,      :5A1A  Rated secondary current: 5A or 1A
3,      Service Condition
3.1,1000; Altitude is not more than 1000m;
3.2,-25ºC~+40ºC; Ambient temperature: -25ºC to +40ºC;
3.3,85%;Relative humidity is not more than 85%;
3.4,,.There shall be the site with no explosive risk and dust and chemical corrosive gas.
4,      ,,3kV,1.Primary to secondary and earth, secondary to earth: 3kv, 1 min.
5,      ,:
=/
For the mulit-turns through core CT, the nos. of turns through core should be calculated as per following formula:
Nos. of primary turns through core=Nos. of rated ampere turns/rated primary current
6,      ,
Rated primary current, accuracy class and corresponding secondary output should refer to the following table:

Type

Rated Primary Current
(A)

Rated Ampere Turns

Rated Secondary Output (VA)
0.5S 0.2 0.5 1 5P6
LMZ1-0.5A 5.10.20.25.50.100 100  
5
-
5
5 7.5 -
15.30.75.150 150
40.200 200
250       250
300 300
400 400
LMZJ1-0.5A 5.10.15.20.25.30.50.
75.100.150.300
300 10 15 -
250 250
40.200.400 400
500 500 10
600 600
750 750
800 800
1000 1000 10 15 20 30 10
1200 1200
1500 1500
 
,Outline and Installation Drawing:
LMZ1-0.5A,5-400A Outline Drawing:
720V Busbar Type Current Transformer

 
LMZJ1-0.5A 500-800A Outline Drawing:
720V Busbar Type Current Transformer

 
LMZJ1-0.5A 1000-1500A Outline Drawing:

 
 