6-66kv Overhead Line Fault Indicator with Remote Monitoring and with IEC101 Communication

Product Details
Customization: Available
Transport Package: Wooden/Carton
Specification: 6-66KV
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500 RMB
Plant Area
1001~2000 square meters
  • 6-66kv Overhead Line Fault Indicator with Remote Monitoring and with IEC101 Communication
  • 6-66kv Overhead Line Fault Indicator with Remote Monitoring and with IEC101 Communication
  • 6-66kv Overhead Line Fault Indicator with Remote Monitoring and with IEC101 Communication
  • 6-66kv Overhead Line Fault Indicator with Remote Monitoring and with IEC101 Communication
Find Similar Products

Basic Info.

Model NO.
ESI
Trademark
HEMG
Origin
China
Production Capacity
1000000

Product Description

6-66kv Overhead Line Fault Indicator with Remote Monitoring and with IEC101 CommunicationAEREAL FAULT INDICATOR
6-66kv Overhead Line Fault Indicator with Remote Monitoring and with IEC101 Communication

6-66kv Overhead Line Fault Indicator with Remote Monitoring and with IEC101 Communication
6-66kv Overhead Line Fault Indicator with Remote Monitoring and with IEC101 Communication
WITH PORTABLE REMOTE CONTROL
WITH REMOTE TERMINAL COMMUNICATION UNIT
WITH VITUAL MANAGEMENT PLATFORM

 
FAILURE INDICATORS FOR AEREAL LINES 6-66 KV
         
Nº  DESCRIPCION UNIDAD REQUERIDO GARANTIZADO
I. MEDIUM VOLTAGE FAILURE  INDICATORS      
1.0 Country of origin   Indicate CHINA
2.0 Maker     HEMG
3.0 Model     ESI
4.0 Manufacturing Standard and Testing   ANSI/IEEE 495: 2007 ANSI/IEEE 495:2007
5.0 Type of Installation   Exterior OUTDOOR
6.0 Opening System   Monofásico SINLE SYSTEM
7.0 Type of operation   Automática y manual AUTOMATION AND MANUAL
8.0 Installation Altitude m.s.n.m. Hasta 4500 4500
9.0 Operating range (system voltages) kV 7 - 66 7-66
10.0 Operating range (system currents) Amp 1 - 600 1-600
11.0 Operating Frequency Hz 60 60/50HZ
12.0 Operating temperature ºC -40 a +85 (-40 TO 85)
13.0 IP Protection Index   IP67 IP67
14.0 Terms of Use   Continuo CONTINUOUS
    - Signal Type Signal   Luminosa: Estroboscópica de alta densidad BRIGHT 
    - Angle of visibility Grados 360 360
    - Continuous display time horas ≥ 700 >=700
    - Indicator life años ≥ 10 10
    - weight kg ≤ 1 0.75
15.0 Indication, minimum visibility distance during sunny day m 100 100
16.0 Identification of Transient and Permanent Failure   Obligatorio YES.COMPLAY
17.0 Conductor section range mm² 25 a 240 25 TO 240
  Short-term current KA 25 25
18.0 Current Sensor      
    - Model     CT
    - Precision   Indicar (+/-3%)
19.0 Voltage sensor      
    - Model     BY CT
      Indicar SELF-SUITABLE 
20.0 Auxiliary Power System - Signal      
    - Internal Battery   Litio  Lithium
    - Rated Voltage Vdc Indicar 3.6V
    - Useful life años ≥ 10 10
21.0 Programmable Parameters for Performance      
    - Trip current range for the indication of the short-circuit current.   Corriente de disparo: Rango de programación de corriente para la indicación de cortocircuito: Desde 10 hasta 1500 A. YES.COMPLAY
      Corriente de disparo: Autoajustable para fallas a tierra: 5 A a 100A (paso de 5 A) YES.COMPLAY
    - Inrush current lock   Si YES.COMPLAY
    - Transient fault indication time   Si, indicar <=40MS
    - Permanent fault indication time   Si, indicar 4/8/12/24 HOURS OPTIONAL 
    - Flash Interval   Si, indicar 5S
    - Flash duration   Si, indicar >=50MS
    - Replacement by Current   Si YES.COMPLAY
    - Replacement by Voltage   Si YES.COMPLAY
    - Manual Reset   Si YES.COMPLAY
    - Remote Reset   Si YES.COMPLAY
22.0 Metal parts exposed to the weathering of the fault indicator shall be hot dip galvanized in accordance with ASTM A153   YES.COMPLAY
23.0 Accessories for Fault Indicator Assembly      
  -Monitor for the validation of the operation of the Fault Indicator   YES.COMPLAY
II. FAULT INDICATOR COMMUNICATION SYSTEM      
1.0 Wireless Local Communication between the Fault Indicator and a physical interface to external RTU or directly to external RTU that acts as a local hub   Sí   YES.COMPLAY
2.0 Bidirectional communication between fault indicator and physical interface to external RTU or directly to external RTU   Sí, Indicar la distancia máxima posible  de comunicación "bidireccional" que ofrece YES,MAX 50M
3.0    Medium of "local communication"   -Indicar medio y características técnicas (Radio frecuencia, Bluetooth, otro medio)
-Indicar la frecuencia de trabajo del Indicador de Falla, si es Libre o licenciada.
YES,RADIO FREQUENCY/433MHZ,FREE
4.0   - Minimum sending signals of the fault indicator by local communication to the RTU that acts as a local hub      
           Transient failure   Si YES
           Permanent failure   Si YES
           Absence of Tension   Si YES
           Presence of Voltage   Si YES
           Line Current Measurement   Si YES
           Measurement of Voltage   Opcional YES FOR BATTERY
III REMOTE TERMINAL UNIT (RTU)      
1.0 Manufacturing and Testing Standard   IEC 61326-1, EN 55022, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-8 IEC 61326-1, EN 55022, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-8
2.0 Powered by battery embedded in the RTU   YES
3.0 Battery Type   Primary cells Lithium Thionyl Chloride (LiSOCl2) YES
4.0 Battery life Años 10 10
5.0 Embedded GPRS Modem   YES
6.0 Real-time synchronization (RTC)   YES
7.0 Type of SIM card, provided by the User.   Sim Card (Indicar tipo NanoSIM o microSIM) SIM CARD
8.0 Degree of protection   IP66 IP66
9.0 Minimum number of digital inputs for fault indicators   12 12
10.0   Allows remote configuration of fault indicator   Sí, herramienta para la validación del funcionamiento  YES
11.0 Permanent dispatch capacity to the SCADA of the Companies of the Distriluz Group; Directly or through the virtual platform of management of all the data received from the fault indicator   Si, indicar sí es posible el envío directamente o a través de la plataforma virtual YES,POSSIBLE BY DIRECTLY OR BY VIRTUAL PLATEFORM
12.0   Ability to store latest faults >= 10  Si 10
13.0 Mounting Accessories      
  - Boxes with clamps for mounting in post of concentrators according to the manufacturer's recommendations.    Si YES
IV REMOTE CONTROL OF FAULT INDICATORS (1)      
1.0   Allows you to make configuration settings in the Field Fault Indicator   YES
2.0   Stores settings to be applied in the field   YES
3.0   Allows you to download equipment configurations in the field   YES
4.0   Connects to a PC to download stored data   Opcional NO
V VIRTUAL INFORMATION MANAGEMENT PLATFORM      
1.0 CPU and monitor for implementation in the control center   Sí/No (2) YES
2.0 Management Software for windows 8 or higher operating system   YES
3.0 Includes Unlimited Software Management License and its update for a minimum period of 10 years.   YES
4.0 Communication interface with the SCADA of the companies of the Distriluz Group   YES
5.0 Allows user and password access   YES
6.0 Configurable environment by the User   YES
7.0 Set of sound and visual alarms (mimic diagram)   YES
8.0 Allows the configuration of alerts via Email and SMS   YES
  Allows the download of information stored in EXCEL format   YES

 