Recloser Communication Sent Digital Signals Through Communications Port at Protection Speed to Scada

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of US$ 20000/Piece
Request Sample
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500 RMB
Plant Area
1001~2000 square meters
  • Recloser Communication Sent Digital Signals Through Communications Port at Protection Speed to Scada
  • Recloser Communication Sent Digital Signals Through Communications Port at Protection Speed to Scada
  • Recloser Communication Sent Digital Signals Through Communications Port at Protection Speed to Scada
Find Similar Products

Basic Info.

Model NO.
CHZ4C
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000
Transport Package
Wooden
Specification
27KV
Trademark
HEMG
Origin
China
Production Capacity
5000

Product Description

1.MIRRORED BITS communications creates a virtual connection between the two SEL relays as the RMB of one  device follow the status of the respective TMB sent from the other device. 
2.The MIRRORED BITS communications log takes the guesswork out of your communications system's performance. When the MIRRORED BITS channel is active, a communications summary report specific to the performance of that channel is enabled.
3.You can also use MIRRORED BITS to establish an engineering connection with a remote relay via a virtual terminal for easier access. For accurate event logging, MIRRORED BITS lets you synchronize internal clocks in other relays.
4.Using a relay-to-relay fiber-optic channel, MIRRORED BITS lets you eliminate control wiring between a circuit breaker and its associated relay. Fiber optics eliminates dc ground loops and hazardous induced voltages caused by ground  potential rise.
MIRRORED BITS also enables SCADA systems to track the breaker position and condition for improved system performance.




 
  ÍTEM DESCRIPTION UNIT GUARANTEED REQUIRED
  1 GENERAL CHARACTERISTICS.      
  1.1 Maker.   HEMG INDICATE
  1.2 Model.   CHZ4 INDICATE
  1.3 Country of manufacture.   CHINA INDICATE
  1.4 Manufacturing and Testing Standards.   IEC ANSI AND /OR  IEC
  1.5 Mounting.   OUTDOOR OUTDOOR
  1.6 System .   THREE PHASE THREE PHASE
  1.8 Altitude. M.O.S.L 4000 4000
  1.9 Operating temperature ºC (-20ºC TO +50ºC) DE -20 A + 50
  2.0 CHARACTERISTICS OF THE RECONNECTOR.      
  2.1 Nominal frecuency. Hz 60 60
  2.2 Nominal Current of Operation. A 630 630
  2.3 Nominal Symmetrical Interruption Current. kA 12.5 12.5
  2.4 Nominal Tension of Operation. kV 22.9 22.9
  2.5 Maximum Design Tension kV 38 38
  2.6 Internal arc-proof tank (Attach Certificate). N/A OPTIONAL
  2.7 Material . STAINLESS STEEL stainless steel
  2.8 Basic Insulation Level (BIL) 1,2 / 50 us. kVp 170 170
  2.9 Sustaining voltage at industrial frequency at 1 minute dry. kVef 70 70
  2.1 Holding tension at industrial frequency at 10 seconds wet. kVef 60 60
  2.11 Medium of interruption of the electric arc.   VACUUM Vaccum
  2.12 Type of isolation of the means of interruption of the electric arc.   SOLID DIELECTRIC Solid dielectric
  2.13 Three internal current transformers, for protection.   YES yes
  2.14 Six capacitive voltage sensors for voltage measurement per phase on both sides of the line (coupled sensors will not be accepted).   YES yes
    Incorporated in the epoxy insulation of each recloser phase.   YES yes
    Accuracy of the voltage amplitude.   ± 2% ± 2%
    Precision of the phase angle.   ± 1° ± 1°
  2.15 Isolators of the type removable and interchangeable by bushing.   YES yes
  2.16 Maximum opening time. seg 0.05 0.05
  2.17 Maximum closing time. seg 0.06 0.06
  2.18 Operation by pole.   YES yes
  2.19 Number of mechanical operations.   10000 10,000
  2.2 Open-closed position indicator visible from the floor.   YES yes
  2.21 Heating resistance.   N/A Optional
  2.22 Equipment with lifting hook.   YES yes
  3 CHARACTERISTICS OF THE ELECTRONIC CONTROL.      
  3.1 Maker.   HEMG indicate
  3.2 Model.   CHK750 indicate
  3.3 Country of manufacture.   CHINA indicate
  3.4 Protection functions (*).   N/A  
    Overcurrent of phases. 50/51 YES yes
    Overcurrent from phase to ground. 50N/51N YES yes
    Directional overcurrent. 67/67N N/A yes
    Sensitive ground fault. SEF MIN1A  YES,  Indicate minimum value
    Over voltage function. 59 YES yes
    Overspray over voltage function. 59N YES yes
    Switch failure functions. 50BF YES yes
    Frequency function 81 O/U YES yes
    Reclose 79 YES yes
  Synchronism check 25 YES yes
  3.5 Minimum tripping currents.      
    Fail between phases. Amp 5 5
    Fault to earth. Amp 5 5
    Mechanical operations indicator.   YES yes
  3.6 Indicator of recloser status.   YES yes
  3.7 Oscillographic record in Contrade format (capture time 3 seconds).   YES  
  3.8 Fault locator.   YES yes
  3.9 Storage of events.   YES yes
  3.1 Parameter display template.   YES yes
  3.11 Binary digital inputs.   8 8
  3.12 Binary digital outputs.   8 8
  3.13 Time synchronization port IRIG-B.   N/A Optional
  3.14 Elements of protection and blocking of harmonic currents.   YES yes
  3.15 Monitoring of the 3 voltage inputs.   YES yes
  3.16 Sag / Swell voltage register for energy quality analysis.   YES yes
  4 COMMUNICATIONS      
  4.1 Communications protocol for sending to Scada.   DNP3.0 DNP3
  4.2 Remote communication via Ethernet with the proprietary software without interrupting the communication of the SCADA system. YES yes
  4.3 Communication port to report to SCADA.   ETHERNET ,RJ45 ETHERNET, RJ45
  4.4 Sent digital signals through communications port at protection speed.   YES yes
  4.5 RS232 or ETHERNET communications port independent from the port for SCADA sending that allows communication between reclosers in a protocol in order to allow fast restoration schemes in the event of a fault between 02 consecutive reclosers.   YES  YES (attach protocol document, please send )
  The signs to be integrated into the SCADA are attached in annexes.
   
  5 ACCESSORIES      
  5.1 Metallic structure for assembly in sub station.   YES yes
  5.2 4 interface cables for configuration with PC four units.   YES yes
  5.3 Configuration software, event analysis and electronic control management.   YES yes
  5.5 Lightning conductor of 21kV 10kAmp.   YES yes
  5.6 Grounding ≤ 10 ohm guaranteed by the contractor.   YES yes
  5.7 Recloser Bushing Wildlife Protectors YES yes
  5.8 Wildlife Protectors of Lightning Rods YES yes
    Cable between control box and reclosrs   YES 8 mts
  6 SPARE PARTS (For the entire recloser lot). Battery Game. Fuses Mascara Front Panel by equipment.      
  6.1 Battery kit YES 18
  6.2  Fuses   YES 90
  6.3 Mask Front Panel by equipment. YES 9
         
  7 Current Transformer   RESIN Resyn
    Maximum allowable stress on the resin   6KN Indicate
           
           
  ÍTEM DESCRIPTION UNIT GUARANTEED REQUIRED
  1 GENERAL CHARACTERISTICS.      
  1.1 Maker.   HEMG INDICATE
  1.2 Model.   CHZ4 INDICATE
  1.3 Country of manufacture.   CHINA INDICATE
  1.4 Manufacturing and Testing Standards.   IEC ANSI AND /OR  IEC
  1.5 Mounting.   OUTDOOR OUTDOOR
  1.6 System .   THREE PHASE THREE PHASE
  1.8 Altitude. M.O.S.L 4000 4000
  1.9 Operating temperature ºC (-20ºC TO +50ºC) DE -20 A + 50
  2.0 CHARACTERISTICS OF THE RECONNECTOR.      
  2.1 Nominal frecuency. Hz 60 60
  2.2 Nominal Current of Operation. A 630 630
  2.3 Nominal Symmetrical Interruption Current. kA 12.5 12.5
  2.4 Nominal Tension of Operation. kV 22.9 22.9
  2.5 Maximum Design Tension kV 38 38
  2.6 Internal arc-proof tank (Attach Certificate). N/A OPTIONAL
  2.7 Material . STAINLESS STEEL stainless steel
  2.8 Basic Insulation Level (BIL) 1,2 / 50 us. kVp 170 170
  2.9 Sustaining voltage at industrial frequency at 1 minute dry. kVef 70 70
  2.1 Holding tension at industrial frequency at 10 seconds wet. kVef 60 60
  2.11 Medium of interruption of the electric arc.   VACUUM Vaccum
  2.12 Type of isolation of the means of interruption of the electric arc.   SOLID DIELECTRIC Solid dielectric
  2.13 Three internal current transformers, for protection.   YES yes
  2.14 Six capacitive voltage sensors for voltage measurement per phase on both sides of the line (coupled sensors will not be accepted).   YES yes
    Incorporated in the epoxy insulation of each recloser phase.   YES yes
    Accuracy of the voltage amplitude.   ± 2% ± 2%
    Precision of the phase angle.   ± 1° ± 1°
  2.15 Isolators of the type removable and interchangeable by bushing.   YES yes
  2.16 Maximum opening time. seg 0.05 0.05
  2.17 Maximum closing time. seg 0.06 0.06
  2.18 Operation by pole.   YES yes
  2.19 Number of mechanical operations.   10000 10,000
  2.2 Open-closed position indicator visible from the floor.   YES yes
  2.21 Heating resistance.   N/A Optional
  2.22 Equipment with lifting hook.   YES yes
  3 CHARACTERISTICS OF THE ELECTRONIC CONTROL.      
  3.1 Maker.   HEMG indicate
  3.2 Model.   CHKR5300 indicate
  3.3 Country of manufacture.   CHINA indicate
  3.4 Protection functions (*).   N/A  
    Overcurrent of phases. 50/51 YES yes
    Overcurrent from phase to ground. 50N/51N YES yes
    Directional overcurrent. 67/67N N/A yes
    Sensitive ground fault. SEF MIN1A  YES,  Indicate minimum value
    Over voltage function. 59 YES yes
    Overspray over voltage function. 59N YES yes
    Switch failure functions. 50BF YES yes
    Frequency function 81 O/U YES yes
    Reclose 79 YES yes
  Synchronism check 25 YES yes
  3.5 Minimum tripping currents.      
    Fail between phases. Amp 5 5
    Fault to earth. Amp 5 5
    Mechanical operations indicator.   YES yes
  3.6 Indicator of recloser status.   YES yes
  3.7 Oscillographic record in Contrade format (capture time 3 seconds).   YES  
  3.8 Fault locator.   YES yes
  3.9 Storage of events.   YES yes
  3.1 Parameter display template.   YES yes
  3.11 Binary digital inputs.   8 8
  3.12 Binary digital outputs.   8 8
  3.13 Time synchronization port IRIG-B.   N/A Optional
  3.14 Elements of protection and blocking of harmonic currents.   YES yes
  3.15 Monitoring of the 3 voltage inputs.   YES yes
  3.16 Sag / Swell voltage register for energy quality analysis.   YES yes
  4 COMMUNICATIONS      
  4.1 Communications protocol for sending to Scada.   DNP3.0 DNP3
  4.2 Remote communication via Ethernet with the proprietary software without interrupting the communication of the SCADA system. YES yes
  4.3 Communication port to report to SCADA.   ETHERNET ,RJ45 ETHERNET, RJ45
  4.4 Sent digital signals through communications port at protection speed.   YES yes
  4.5 RS232 or ETHERNET communications port independent from the port for SCADA sending that allows communication between reclosers in a protocol in order to allow fast restoration schemes in the event of a fault between 02 consecutive reclosers.   YES  YES (attach protocol document, please send )
  The signs to be integrated into the SCADA are attached in annexes.
   
  5 ACCESSORIES      
  5.1 Metallic structure for assembly in sub station.   YES yes
  5.2 4 interface cables for configuration with PC four units.   YES yes
  5.3 Configuration software, event analysis and electronic control management.   YES yes
  5.5 Lightning conductor of 21kV 10kAmp.   YES yes
  5.6 Grounding ≤ 10 ohm guaranteed by the contractor.   YES yes
  5.7 Recloser Bushing Wildlife Protectors YES yes
  5.8 Wildlife Protectors of Lightning Rods YES yes
    Cable between control box and reclosrs   YES 8 mts
  6 SPARE PARTS (For the entire recloser lot). Battery Game. Fuses Mascara Front Panel by equipment.      
  6.1 Battery kit YES 18
  6.2  Fuses   YES 90
  6.3 Mask Front Panel by equipment. YES 9
         
  7 Current Transformer   RESIN Resyn
    Maximum allowable stress on the resin   6KN Indicate
           
           

Recloser Communication Sent Digital Signals Through Communications Port at Protection Speed to Scada
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now