• 12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line
  • 12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line
  • 12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line
  • 12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line
  • 12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line
  • 12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line

12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line

Application: Winding Wire Coating Insulation
Type: Insulation Sleeve & Tube
Chemistry: Organic Insulation
Material: Rubber
Thermal Rating: H 180
Maximum Voltage: 20KV~100KV
Samples:
US$ 100/Meter 1 Meter(Min.Order)
| Request Sample
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
SILICON
Classification
Hybrid Insulation Materials
Certification
ISO9001
Color
Brown
Transport Package
Wooden
Specification
12KV/24KV
Trademark
HEMG
Origin
China
Production Capacity
10000

Product Description

12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line
12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line
12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line
12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line
12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line12kv/24kv/38kv Silicon Rubber Insulating Cover of Ascr AAAC for Over Head Line
  ITEM 1  : INSULATION COVER FOR 70 MM2  - 15 KV
ITEM SPECIFICATIONS UNIT REQUIRED GUARANTEED
1 GENERAL DATA      
1.1 MANUFACTURER   INDICATE HEMG
  COUNTRY   INDICATE China
1.2 MATERIAL OF INSULATION COVER   SILICON RUBBER SILICONE RUBBER
1.3 MODEL OR CATALOGUE NUMBER   INDICATE WSKG
1.4 CERTIFICATE ISO 9001 AND ISO 14001   YES YES
1.5 STANDARDS OF MANUFACTURE AND TESTS   ACCORDING POINT 2  
2 CONDITIONS OF OPERATION IN CONTINUOUS REGIME OF THE INSULATING COVERS.      
2.1 MAXIMUM VOLTAGE. KV 15 15
2.3 NOMINAL VOLTAGES OF THE NETWORK. KV 10, 13.2, 13.8 10, 13.2, 13.8
2.4 FREQUENCY HZ 60 60
2.5 CALIBER OF CABLES WHERE THEY WILL BE INSTALLED.   UNTIL 70 MM2 UNTIL 70 MM2
2.6 MATERIAL OF THE CABLES WHERE THEY WILL BE INSTALLED.   CU AND AAAC CU AND AL
3 ELECTRICAL PROPERTIES OF THE COVER MATERIAL (1).      
3.1 DIELECTRIC STRENGTH. KV/CM 175 OR MORE ≥175
3.2 VOLUMETRIC RESISTIVITY. OHM/CM 1X10  13 OR MORE 1X10  14
3.3 CONSTANT DIELECTRIC.   5 OR LESS 2-3
4 VOLTAGES OF PROOF OF THE COVER (1).      
4.1 A NOMINAL FREQUENCY IN DRY 1 MINUTE. KV 15 15
4.2 A INDUSTRIAL FREQUENCY IN WET 1 MINUTE. KV 15 15
5 PROPERTIES OF THE MATERIAL OF THE INSULATING COVER (1).      
5.1 BREAKING STRAIN. Mpa 4.8 OR MORE 4
5.2 ELONGATION OF BREAK. % 200 OR MORE ≥200
5.3 RANGE OF OPERATING TEMPERATURE. °C FROM -10 TO +100 from -10C to +100C
5.4 WATER ABSORPTION. % 1 OR LESS 1 or less
5.5 RESISTANCE TO UV RAYS.   YES yes
5.6 RESISTANT TO TRACKING   YES yes
5.7 RESSITANTE TO THE MOZONO.   YES yes
5.8 RESISTANT TO URIC ACID AND FATS.   YES yes
5.9 RESISTANT TO THE RIPPED.   YES yes
6 DIMENSIONS AND DESIGN OF THE COVERS (2).      
6.1 COVER DESIGN   INDICATE ADN SCHEME  
6.2 THICKNESS. mm INDICATE. ≥2.3
6.3 INSIDE DIAMETER. mm  INDICATE 12
6.4 CABLE CALIBERS TO COVER. mm2 INDICATE 70
6.5 LABELED.   BRAND AND MODEL No
7 INSTALLATION OF COVER WITH ENERGIZED LINE AND ITS ACCESSORIES (3).      
7.1 EASY TO INSTALL.   YES , INCLUDE GUIDE YES , INCLUDE GUIDE
Pay attention to the personal safety with energized line
7.2 INCLUDE RETAIN ACCESSORIES FOR FIXING THE CABLES AND AVOIDING SLIDES AFTER INSTALLATION.   YES, TWO UNITS FOR EVERY 10 MTS OF COVER. CABLE TIE
7.3 INCLUDE TOOLS FOR INSTALLATION AND CLOSURE OF THE COVER THAT GUARANTEE THAT DURING ITS OPERATION IS SLIDING ON THE CABLE AND PERIMETER ITS MOUNTING FROM A FIXED POINT OF THE INSTALLER WITH THE SPECIFIED TOOL.   YES, 5 EQUIPMENTS FOR MOUNTING  YES
7.4 REUSABLE.   YES YES, IF REQUIRED, WITHOUT GLUE
8 PACKING REQUIREMENTS.      
8.1 METERS OF COVER BY ROLL. MTS INDICATE 100
8.2 WEIGHT OF EACH ROLL. KG INDICATE 10
8.3 PACKAGING RESISTANT TO BLOWS AND FALL OF ACIDS.   INDICATE YES
9 PRESENT SAMPLE  OF THE COVER AND FIXING ACCESSORIES.   YES, COVER AND ACCESORIE FOR MOUNTING. YES
         
  NOTE   :       
  THE PROPERTIES OF THE INSULATING COVERS ARE REFERRED TO THE MANUFACTURING STANDARDS INDICATED IN THE NUMBER 2 attached.
  IT MUST INCLUDE ROOF DESIGN DESIGNS INDICATING ALL DIMENSIONS, PLANS OF ACCESSORIES, FLATS OF FIXING ELEMENTS AND CLOSURE OF INSULATING COVERS.
  THE FOLLOWING TECHNICAL DOCUMENTATION MUST BE INCLUDED.
  Installation manuals, information on the technical characteristics of the fixing accessories, closure of the insulating covers and manuals for the use of the tools.
         
  ITEM 2  : INSULATION COVER FOR 70 MM2  - 25 KV      
ITEM SPECIFICATIONS UNIT REQUIRED GUARANTEED
1 GENERAL DATA      
1.1 MANUFACTURER   INDICATE HEMG
  COUNTRY   INDICATE China
1.2 MATERIAL OF INSULATION COVER   SILICON RUBBER SILICONE RUBBER
1.3 MODEL OR CATALOGUE NUMBER   INDICATE WSKG
1.4 CERTIFICATE ISO 9001 AND ISO 14001   YES YES
1.5 STANDARDS OF MANUFACTURE AND TESTS   ACCORDING POINT 2  
2 CONDITIONS OF OPERATION IN CONTINUOUS REGIME OF THE INSULATING COVERS.      
2.1 MAXIMUM VOLTAGE. KV 25 25
2.3 NOMINAL VOLTAGES OF THE NETWORK. KV 22.9 22.9
2.4 FREQUENCY HZ 60 60
2.5 CALIBER OF CABLES WHERE THEY WILL BE INSTALLED.   UNTIL 70 MM2 UNTIL 70 MM2
2.6 MATERIAL OF THE CABLES WHERE THEY WILL BE INSTALLED.   CU AND AAAC CU AND AL
3 ELECTRICAL PROPERTIES OF THE COVER MATERIAL (1).      
3.1 DIELECTRIC STRENGTH. KV/CM 175 OR MORE ≥175
3.2 VOLUMETRIC RESISTIVITY. OHM/CM 1X10  13 OR MORE 1X10  14
3.3 CONSTANT DIELECTRIC.   5 OR LESS 2-3
4 VOLTAGES OF PROOF OF THE COVER (1).      
4.1 A NOMINAL FREQUENCY IN DRY 1 MINUTE. KV 25 25
4.2 A INDUSTRIAL FREQUENCY IN WET 1 MINUTE. KV 25 25
5 PROPERTIES OF THE MATERIAL OF THE INSULATING COVER (1).      
5.1 BREAKING STRAIN. Mpa 4.8 OR MORE 4
5.2 ELONGATION OF BREAK. % 200 OR MORE ≥200
5.3 RANGE OF OPERATING TEMPERATURE. °C FROM -10 TO +100 from -10C to +100C
5.4 WATER ABSORPTION. % 1 OR LESS 1 or less
5.5 RESISTANCE TO UV RAYS.   YES yes
5.6 RESISTANT TO TRACKING   YES yes
5.7 RESSITANTE TO THE MOZONO.   YES yes
5.8 RESISTANT TO URIC ACID AND FATS.   YES yes
5.9 RESISTANT TO THE RIPPED.   YES yes
6 DIMENSIONS AND DESIGN OF THE COVERS (2).      
6.1 COVER DESIGN   INDICATE ADN SCHEME  
6.2 THICKNESS. mm INDICATE. ≥3
6.3 INSIDE DIAMETER. mm  INDICATE 12
6.4 CABLE CALIBERS TO COVER. mm2 INDICATE 70
6.5 LABELED.   BRAND AND MODEL No
7 INSTALLATION OF COVER WITH ENERGIZED LINE AND ITS ACCESSORIES (3).      
7.1 EASY TO INSTALL.   YES , INCLUDE GUIDE YES , INCLUDE GUIDE
Pay attention to the personal safety with energized line
7.2 INCLUDE RETAIN ACCESSORIES FOR FIXING THE CABLES AND AVOIDING SLIDES AFTER INSTALLATION.   YES, TWO UNITS FOR EVERY 10 MTS OF COVER. CABLE TIE
7.3 INCLUDE TOOLS FOR INSTALLATION AND CLOSURE OF THE COVER THAT GUARANTEE THAT DURING ITS OPERATION IS SLIDING ON THE CABLE AND PERIMETER ITS MOUNTING FROM A FIXED POINT OF THE INSTALLER WITH THE SPECIFIED TOOL.   YES, 5 EQUIPMENTS FOR MOUNTING YES,
7.4 REUSABLE.   YES YES, IF REQUIRED, WITHOUT GLUE
8 PACKING REQUIREMENTS.      
8.1 METERS OF COVER BY ROLL. MTS INDICATE 100
8.2 WEIGHT OF EACH ROLL. KG INDICATE 10
8.3 PACKAGING RESISTANT TO BLOWS AND FALL OF ACIDS.   INDICATE YES
9 PRESENT SAMPLE  OF THE COVER AND FIXING ACCESSORIES.   YES, COVER AND ACCESORIE FOR MOUNTING. YES
         
  NOTE   :       
  THE PROPERTIES OF THE INSULATING COVERS ARE REFERRED TO THE MANUFACTURING STANDARDS INDICATED IN THE NUMBER 2 attached.
  IT MUST INCLUDE ROOF DESIGN DESIGNS INDICATING ALL DIMENSIONS, PLANS OF ACCESSORIES, FLATS OF FIXING ELEMENTS AND CLOSURE OF INSULATING COVERS.
  THE FOLLOWING TECHNICAL DOCUMENTATION MUST BE INCLUDED.
  Installation manuals, information on the technical characteristics of the fixing accessories, closure of the insulating covers and manuals for the use of the tools.
         
         
  ITEM 3  : INSULATION COVER FOR 120 MM2  - 15 KV      
ITEM SPECIFICATIONS UNIT REQUIRED GUARANTEED
1 GENERAL DATA      
1.1 MANUFACTURER   INDICATE HEMG
  COUNTRY   INDICATE China
1.2 MATERIAL OF INSULATION COVER   SILICON RUBBER SILICONE RUBBER
1.3 MODEL OR CATALOGUE NUMBER   INDICATE WSKG
1.4 CERTIFICATE ISO 9001 AND ISO 14001   YES YES
1.5 STANDARDS OF MANUFACTURE AND TESTS   ACCORDING POINT 2 YES
2 CONDITIONS OF OPERATION IN CONTINUOUS REGIME OF THE INSULATING COVERS.      
2.1 MAXIMUM VOLTAGE. KV 15 15
2.3 NOMINAL VOLTAGES OF THE NETWORK. KV 10, 132, 13.8 10, 13.2, 13.8
2.4 FREQUENCY HZ 60 60
2.5 CALIBER OF CABLES WHERE THEY WILL BE INSTALLED.   UNTIL  120 MM2 UNTIL 120 MM2
2.6 MATERIAL OF THE CABLES WHERE THEY WILL BE INSTALLED.   CU AND AAAC CU AND AL
3 ELECTRICAL PROPERTIES OF THE COVER MATERIAL (1).      
3.1 DIELECTRIC STRENGTH. KV/CM 175 OR MORE ≥175
3.2 VOLUMETRIC RESISTIVITY. OHM/CM 1X10  13 OR MORE 1X10  14
3.3 CONSTANT DIELECTRIC.   5 OR LESS 2-3
4 VOLTAGES OF PROOF OF THE COVER (1).      
4.1 A NOMINAL FREQUENCY IN DRY 1 MINUTE. KV 15 15
4.2 A INDUSTRIAL FREQUENCY IN WET 1 MINUTE. KV 15 15
5 PROPERTIES OF THE MATERIAL OF THE INSULATING COVER (1).      
5.1 BREAKING STRAIN. Mpa 4.8 OR MORE 4
5.2 ELONGATION OF BREAK. % 200 OR MORE ≥200
5.3 RANGE OF OPERATING TEMPERATURE. °C FROM -10 TO +100 from -10C to +100C
5.4 WATER ABSORPTION. % 1 OR LESS 1 or less
5.5 RESISTANCE TO UV RAYS.   YES yes
5.6 RESISTANT TO TRACKING   YES yes
5.7 RESSITANTE TO THE MOZONO.   YES yes
5.8 RESISTANT TO URIC ACID AND FATS.   YES yes
5.9 RESISTANT TO THE RIPPED.   YES yes
6 DIMENSIONS AND DESIGN OF THE COVERS (2).      
6.1 COVER DESIGN   INDICATE ADN SCHEME  
6.2 THICKNESS. mm INDICATE. ≥2.3
6.3 INSIDE DIAMETER. mm  INDICATE 15.6
6.4 CABLE CALIBERS TO COVER. mm2 INDICATE 120
6.5 LABELED.   BRAND AND MODEL No
7 INSTALLATION OF COVER WITH ENERGIZED LINE AND ITS ACCESSORIES (3).      
7.1 EASY TO INSTALL.   YES , INCLUDE GUIDE YES , INCLUDE GUIDE
Pay attention to the personal safety with energized line
7.2 INCLUDE RETAIN ACCESSORIES FOR FIXING THE CABLES AND AVOIDING SLIDES AFTER INSTALLATION.   YES, TWO UNITS FOR EVERY 10 MTS OF COVER. CABLE TIE
7.3 INCLUDE TOOLS FOR INSTALLATION AND CLOSURE OF THE COVER THAT GUARANTEE THAT DURING ITS OPERATION IS SLIDING ON THE CABLE AND PERIMETER ITS MOUNTING FROM A FIXED POINT OF THE INSTALLER WITH THE SPECIFIED TOOL.   YES, 5 EQUIPMENTS FOR MOUNTING YES
7.4 REUSABLE.   YES YES, IF REQUIRED, WITHOUT GLUE
8 PACKING REQUIREMENTS.      
8.1 METERS OF COVER BY ROLL. MTS INDICATE 100
8.2 WEIGHT OF EACH ROLL. KG INDICATE 10
8.3 PACKAGING RESISTANT TO BLOWS AND FALL OF ACIDS.   INDICATE YES
9 PRESENT SAMPLE  OF THE COVER AND FIXING ACCESSORIES.   YES, COVER AND ACCESORIE FOR MOUNTING. YES
         
  NOTE   :       
  THE PROPERTIES OF THE INSULATING COVERS ARE REFERRED TO THE MANUFACTURING STANDARDS INDICATED IN THE NUMBER 2 attached.
  IT MUST INCLUDE ROOF DESIGN DESIGNS INDICATING ALL DIMENSIONS, PLANS OF ACCESSORIES, FLATS OF FIXING ELEMENTS AND CLOSURE OF INSULATING COVERS.
  THE FOLLOWING TECHNICAL DOCUMENTATION MUST BE INCLUDED.
  Installation manuals, information on the technical characteristics of the fixing accessories, closure of the insulating covers and manuals for the use of the tools.
         
         
  ITEM 4  : INSULATION COVER FOR 120 MM2  - 25 KV      
ITEM SPECIFICATIONS UNIT REQUIRED GUARANTEED
1 GENERAL DATA      
1.1 MANUFACTURER   INDICATE HEMG
  COUNTRY   INDICATE China
1.2 MATERIAL OF INSULATION COVER   SILICON RUBBER SILICONE RUBBER
1.3 MODEL OR CATALOGUE NUMBER   INDICATE WSKG
1.4 CERTIFICATE ISO 9001 AND ISO 14001   YES YES
1.5 STANDARDS OF MANUFACTURE AND TESTS   ACCORDING POINT 2  
2 CONDITIONS OF OPERATION IN CONTINUOUS REGIME OF THE INSULATING COVERS.      
2.1 MAXIMUM VOLTAGE. KV 25 25
2.3 NOMINAL VOLTAGES OF THE NETWORK. KV 22.9 22.9
2.4 FREQUENCY HZ 60 60
2.5 CALIBER OF CABLES WHERE THEY WILL BE INSTALLED.   UNTIL  120 MM2 UNTIL 120 MM2
2.6 MATERIAL OF THE CABLES WHERE THEY WILL BE INSTALLED.   CU AND AAAC CU AND AL
3 ELECTRICAL PROPERTIES OF THE COVER MATERIAL (1).      
3.1 DIELECTRIC STRENGTH. KV/CM 175 OR MORE ≥175
3.2 VOLUMETRIC RESISTIVITY. OHM/CM 1X10  13 OR MORE 1X10  14
3.3 CONSTANT DIELECTRIC.   5 OR LESS 2-3
4 VOLTAGES OF PROOF OF THE COVER (1).      
4.1 A NOMINAL FREQUENCY IN DRY 1 MINUTE. KV 15 15
4.2 A INDUSTRIAL FREQUENCY IN WET 1 MINUTE. KV 15 15
5 PROPERTIES OF THE MATERIAL OF THE INSULATING COVER (1).      
5.1 BREAKING STRAIN. Mpa 4.8 OR MORE 4
5.2 ELONGATION OF BREAK. % 200 OR MORE ≥200
5.3 RANGE OF OPERATING TEMPERATURE. °C FROM -10 TO +100 from -10C to +100C
5.4 WATER ABSORPTION. % 1 OR LESS 1 or less
5.5 RESISTANCE TO UV RAYS.   YES yes
5.6 RESISTANT TO TRACKING   YES yes
5.7 RESSITANTE TO THE MOZONO.   YES yes
5.8 RESISTANT TO URIC ACID AND FATS.   YES yes
5.9 RESISTANT TO THE RIPPED.   YES yes
6 DIMENSIONS AND DESIGN OF THE COVERS (2).      
6.1 COVER DESIGN   INDICATE ADN SCHEME  
6.2 THICKNESS. mm INDICATE. ≥3
6.3 INSIDE DIAMETER. mm  INDICATE 15.6
6.4 CABLE CALIBERS TO COVER. mm2 INDICATE 120
6.5 LABELED.   BRAND AND MODEL No
7 INSTALLATION OF COVER WITH ENERGIZED LINE AND ITS ACCESSORIES (3).      
7.1 EASY TO INSTALL.   YES , INCLUDE GUIDE YES , INCLUDE GUIDE
Pay attention to the personal safety with energized line
7.2 INCLUDE RETAIN ACCESSORIES FOR FIXING THE CABLES AND AVOIDING SLIDES AFTER INSTALLATION.   YES, TWO UNITS FOR EVERY 10 MTS OF COVER. CABLE TIE
7.3 INCLUDE TOOLS FOR INSTALLATION AND CLOSURE OF THE COVER THAT GUARANTEE THAT DURING ITS OPERATION IS SLIDING ON THE CABLE AND PERIMETER ITS MOUNTING FROM A FIXED POINT OF THE INSTALLER WITH THE SPECIFIED TOOL.   YES, 5 EQUIPMENTS FOR MOUNTING YES
7.4 REUSABLE.   YES YES, IF REQUIRED, WITHOUT GLUE
8 PACKING REQUIREMENTS.      
8.1 METERS OF COVER BY ROLL. MTS INDICATE 100
8.2 WEIGHT OF EACH ROLL. KG INDICATE 10
8.3 PACKAGING RESISTANT TO BLOWS AND FALL OF ACIDS.   INDICATE YES
9 PRESENT SAMPLE  OF THE COVER AND FIXING ACCESSORIES.   YES, COVER AND ACCESORIE FOR MOUNTING. YES
         
  NOTE   :       
  THE PROPERTIES OF THE INSULATING COVERS ARE REFERRED TO THE MANUFACTURING STANDARDS INDICATED IN THE NUMBER 2 attached.
  IT MUST INCLUDE ROOF DESIGN DESIGNS INDICATING ALL DIMENSIONS, PLANS OF ACCESSORIES, FLATS OF FIXING ELEMENTS AND CLOSURE OF INSULATING COVERS.
  THE FOLLOWING TECHNICAL DOCUMENTATION MUST BE INCLUDED.
  Installation manuals, information on the technical characteristics of the fixing accessories, closure of the insulating covers and manuals for the use of the tools.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation
Registered Capital
500 RMB
Plant Area
1001~2000 square meters