Ied′s Differential Protection and Automatic System of 69kv Line

Task: Program
Structure: Combination
Mathematical Model: Linear
Signal: Continuous
Function: Automatic Control, Protection, Monitoring, Measurement
Certification: ISO: 9001, CE
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
SEL311L
Condition
New
Customized
Non-Customized
Transport Package
Carton with Wooden
Specification
6-66KV
Trademark
SEL/ABB/SCHNEIDER/CHINA
Origin
China
Production Capacity
100000

Product Description


Ied′s Differential Protection and Automatic System of 69kv Line

 
  IED´S LINE PROTECTION RELAY 69KV 
PROTECTIONS  
QUANTITY 2  2
MOUNTING INCLUDING WHERE CNEL EP INDICATE YES
LINE DIFERECIAL 87 L 87L
DISTANCE FROM LINE LESS than 100 km, which the supplier provides if need DIMMER Approximately 100KM
PUTT - POTT-PROTECTION SCHEME BASED ON ANSI 78 ANSI 78
DISTANCE 21, MHO AND CUDRILATERAL; OR ONLY QUADRILATERAL 21, MHO,QUADRILATERAL
FAULT LOCATOR 21 FL, PROGRAMMABLE 21 FL, PROGRAMMABLE
OVERCURRENT ( 1 and 2 WINDINGS ));
CURVES ANSI - IEC
50/51 50/51
50N/51N 50N/51N
5OG / 51G 5OG / 51G
DIRECTIONAL 67 F, 67 N 67 , 67 N
POLARIZATION BY VOLTAGE OR CURRENT VOLTAGE
ADJUSTMENTS OF ANGLES RCA/ROA RCA
FAULT FUSE YES, TO BLOCK THE DISTANCE IN CASE OF
LOSS OF VOLTAGE FROM THE PT´S
YES, TO BLOCK THE DISTANCE IN CASE OF
LOSS OF VOLTAGE FROM THE PT´S
HIGH IMPEDANCE FAULT HIGH IMPEDANCE FAULT HIGH IMPEDANCE FAULT
LOW VOLTAGE 27; PROGRAMMABLE BY THE USER 27; PROGRAMMABLE BY THE USER
OVER VOLTAGE 79y PROGRAMMABLE BY THE USER 59 PROGRAMMABLE BY THE USER
BREAKER FAILURE 50BF YES
PROTOCOL IEEE C37.94 IEEEC37.94
MEASUREMENTS  
I dif. Differential current YES
(I) bar. Current restraining YES
I Primary and secondary winding current YES
CURRENT I YES
VOLTAGE V YES
POWER FACTOR FP YES
POWERS ACTIVE, REACTIVE AND APPARENT ACTIVE, REACTIVE AND APPARENT
KEYPAD OPTION  
OPEN   YES
CLOSE   YES
TRIGGER TRIPOLAR YES
EVENT LOG  
OSCILOGRAFIAS Pre fails - post failure YES
DATE   YES
TIME   YES
FAULT CURRENT SEQUENCE +, - AND 0   YES
FAULT SIGNALLING USE OF LED LDC AND LED
INPUTS AND DIGITAL OUTPUTS  
DIGITAL INPUTS 6 MINIMUM 16
DIGITAL OUTPUTS 6 MINIMUM 14
CURRENT NOMINAL SECONDARY 1-5 AMP 1 A  AND 5A
ADJUST TAP LESSER or equal 0.5 In YES
STANDARDS ANSI-IEC ANSI  IEC
POWER SUPPLY 1 80-240 VDC 24 - 48Vdc 1
48 - 110Vdc (40-100Vac)
110 - 250Vdc (100-240Vac)
POWER 2 80-240 Vac NA
PULSES OF VOLTAGE DIGITAL INPUT, DIGITAL OUTPUT 60%-80%Uaux
WARRANTY  
10 YEARS MINIMUM 2years
TERMINAL TEST - SHORTCIRCUITABLE  
TERMINAL TEST - SHORTCIRCUITABLE SHORTCIRCUITABLE TERMINALS AND TESTS SHOULD COME WITH THE INSTALLATION MANUAL IN SPANISH, THE TERMINAL BOARD MUST BE ABLE TO WITHSTAND VALUE OF INJECTION OF SECONDARY CURRENT MINIMUM 100 A. IS ACCEPTED THAT THE TWO TERMINALS COME IN A SINGLE ELEMENT, IN CASE THAT THE PURCHASE INCLUDE BOARD POSITION, TERMINALS MUST BE ALREADY INSTALLED AND READY TO OPERATE. THE PROTECTIONS OF CNEL EP GROUP WILL CARRY OUT INJECTION TESTING ALTOGETHER WITH A TECHNICIAN OF MANUFACTURES OR SERVICEMAN OF THE OFFEROR AND VERIFY THE OPERATION THEREOF IN CONJUNCTION WITH THE PROTECTION RELAY. yes
CERTIFICATES  
CERTIFICATE OF SOLE REPRESENTATIVE AUTHORIZED BRAND IN PROTECTION RELAYS OK YES
CERTIFICATE KEMA IEC 61850-6, 7-1, 7-2, 7-3, 7-4 and 8-1 OK YES
CERTIFIED ISO STANDARD 9001 OK YES
CERTIFIED NOTARIZED THAT CONSISTS WITH TECHNICAL
IN ECUADOR TO HAVE IMMEDIATE SOLUTIONS.
OK YES
CERTIFIED TRAINING  
TRAINING CERTIFIED IN SPANISH LANGUAGE WITH CERTIFIED INSTRUCTOR FROM FACTORY  
1 training 5 days, after that the OFFEROR is required to give training for a year until they are solvent doubts IED´s. this under prior coordination with the administrator of the contract of CNEL EP, these skills will be two-day minimum 5 times A year, to failure to comply with this shall present its poor compliance for future contracts offered by CNEL EP.
YES but the language is English
2 SUBJECT PROTECTIONS SETTINGS, THE PERSON WHO WILL GIVE THE TRAINING MUST BE PROTECTIONS ENG. AND SHOULD BE IN FULL KNOWLEDGE OF THE SUBJECT, ABLE TO RESOLVE ALL QUESTIONS SUBMITTED AT THAT TIME. YES but the language is English
3. COMMUNICATION TO THE CONTRACT ADMINISTRATOR YES but the language is English
4. IEC 61850, WANT TO MAKE AN EXAMPLE
TWO IED´s this should be demonstrated and
IN FULL ACCEPTANCE OF THE GROUP
ASSISTANT TO THE TRAINING.
YES but the language is English
5. EVIDENCE OF CURRENT INJECTION YES but the language is English
6. INSTALLATION ON THE SAME FIELD, IF IT
REQUESTED SEVERAL INSTALL ONE AS EXAMPLE, PART OF THE TRAINING.
YES but the language is English
LICENSE FREE (N NUMBER OF USERS) 3
LOCAL TECHNICAL SUPPORT ADDRESSES, PHONES, RESPONSIBLE
WITH STAFF TO SUPPORT TECHNICIAN, DOCUMENT NOTARIZED SIGNATURE
Please contact the local Schneider
MANUAL Spanish English/Spanish
AMBIENT TEMPERATURE MORE THAN 40 DEGREES, LESS THAN THAN 10 -25ºC~+55ºC
COMMUNICATIONS  
PORTS TYPE DESCRIPTION  
FRONT RJ-45, RS 485 FOR FIELD CONFIGURATION DB9 RS232
2 PORTS, REAR FIBER OPTIC COMMUNICATION WITH OTHER SEPARDOS GEOGRAPHICALLY SUBSTATION RELAY YES(Optional)
 
2 PORTS, REAR ETHERNET NETWORK CONFIGURATION WITH REDUNDANCY DOUBLE, INTEGRATION TO THE SCADA YES(The 2nd Ethernet port is optional)
1 PORT DB9-IRIG-B TIME SYNCHRONIZATION BNC IRIG-B
1 PORT RS-485 THE SCADA INTEGRATION YES
The relay should have all the benefits for the installation of the 87's line, with all the useful fiber ports in connection.  
PROTOCOLS IF  
MODBUS/TCP, DNP3/LAN/WAN, FTP, TELNET, PING, IEC 61850 IEC 61850
SERIAL  
DNP3, MODBUS RTU, DNP3,MODBUS RTU,IEC103
 
 
   