• Chz4-40.5/1600-31.5 Outdoor 3-Phase AC High Voltage Automatic Recloser
  • Chz4-40.5/1600-31.5 Outdoor 3-Phase AC High Voltage Automatic Recloser

Chz4-40.5/1600-31.5 Outdoor 3-Phase AC High Voltage Automatic Recloser

Transport Package: Wooden/Carton
Trademark: HEMG
Origin: China
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
CHZ4
Production Capacity
10000

Product Description

1`CHZ4-40.5/1600-31.5 outdoor 3-phase AC high voltage automatic recloser is an outdoor distribution unit of rated voltage 40.5kV and frequency 50 Hz,which is applicable to the feeder site of substation and the industrial and mining enterprise which need general protection,control and frequent operation of switch.It is compased of Model ZW-40.5/1600-31.5 outdoor high voltage vacuum circuit breaker and Model CDA 901 automatic recloseing controller.
 
Major Technical Parameters
No. Description unit value
1 Rated Voltage     40.5
2 Rated Insulation Leve(Elevation 1000m) 1 min Power Frequency Withstand Voltage dry test KV 95
wet test(earth outside insulation) 85
Lightning Impulse Withstand Voltage (peak value)1.2/50s 185
3 Rated Current A 1600
4 Rated Frequency Hz 50
5 Rated Short Circuit interrupting Current Ka 31.5
6 Rated Sequence Opening-0.3s-Closing and Opening 10~180s Closeing and Opening 10~180s-Closing
7 Rated Short Circuit interrupting Current Interrupting Number of Times Times 20
8 Rated Short Circuit Closeing Current (peak value) KA 80
9 Rated Peak Withstand Current 50
10 Rated Short Time Withstand Current 31.5
11 Fully Breaking Time S <0.125
12 Rated Short Circuit Duration 4
13 Mechanical Endurance Times 10000
14 Rated Operating Voltage and Auxiliary Circuit Rated Voltage V AC220

2`The main body of the circuit breaker feature vacuum extinction,simple srtucture,powerful interrupting capability and long service life.Based on the  mircroprocessor,the controller adopts modular structure and feature easy in operation and maintenance.It is an intelligent device integrating power supply,relayprotection,recloseing control,and fault recording into one.
The major technical parameters of the circuit breaker
No. Description Unit Value
1 Rated Voltage KV 40.5
2 Rated Current A 1600
3 Rated Frequency Hz 50
4 Rated Short Circuit Interupting Curent KA 31.5
5 Rated Short Circuit Cloeing Current KA 80
6 Rated Peak Withstand current KA 80
7 Rated Short Time Withstand Cnrrent KA 31.5
8 Rated Short Circuit Duration S 4
9 Rated Operation Sequence Opening 0.3s Closing and Opening 10~180s closing and Opening 10~180s-Closing
10 Shor Circuit Interrupting Current Under ForeigN Land Earth Fault Condition kA 27.6
11 Rated Insulation Level 1 min Power Frequency Withstand Voltage Dry test kA 95
Wet test kA 85
Lightning Impulse Withstand Voltage(peak value) kA 185
12 Breaking Time ms ≤100
13 Mechanical Endurance Times 10000
14 Rated Short Circuit Interrupting Current Interrupting Number of Times Times 20
The mechanical characteristic parameters of the circuit breaker 
No. Description Unit Value
1 Contact Clearance mm 18±1
2 Contact Overtravel mm 6±1
3 Opening Speed m/s 1.6±0.2
4 Closing Speed m/s 0.8±0.2
5 Three Phases Opeing and Closing Non-synchronizing ms ≤2
6 Phase Center-to-Center Spacing mm 680±2
7 Contact Closing Bounce Time ms ≤3
8 Each Phase Conductive Circuit Resistance μΩ ≤60
9 Closing Time ms 25~60
10 Opening Time ms 20~50
11 Energy Stotage Motor Rated Power W 110
12 Energy Stotage Motor Rated Voltage V AC220
13 Max./Min.Motor Voltage 120%/80%
14 Rated Closing Opening Voltage AC220
15 Max./Min.Closing Operating Voltage 120%/80%
16 Rated Opening Operation Voltage AC220
17 Max./Min.Opening Operating Voltage 120%/62%
The technical parameters of the control mechanism
No. Description Unit Value
1 Rated Operating Voltage Opening Tripper V AC220
Closing Tripper AC220
2 Rated Resistance Opening Tripper Ω 56
Closing Tripper 56
3 Rated Output Power Opening Tripper W 320
Closing Tripper 320
4 Energy Storage Motor Rower W 110
5 Motor Energy Storage Rated Voltage V AC220
6 Energy Storage Time s ≤10

3The Major Technical Parameters of Controller
No. item Value Remarks
1 CT Ratio of Transformation *:5 *:Need NOTES on Purchase Order
2 Input Working Voltage AC220/±20%/50HZ  
3 Output Working Voltage AC220/±20%/50HZ  
4 Protection Accuracy(Current) 5%  
5 Inverse Time Current Protection Inverse Time Current Curve 8group 0.1,0.3,0.5,0.7,0.7,1.2,1.5,1.8
Curve Group 1-8group Step Size 1
Start Current /in  
6 Reclosing Function Number of Times three times Step Size 0.1s
First Reclosing Time 0.3~180s Step Size 0.1s
Second Reclosing Time 10~180S Step Size 0.1s
Third Reclosing Time 10~180S Step Size 0.1s
Reset Time 0.3~180S Step Size 0.1A
7 Small Current Neutral Grouding protection Zero Sequence Current 0.5~10A Step Size 0.01s
Zore Sequence Delay 0.01~600S  
8 Opening and Closing Passive Contact Rating 220VAC<30A  
9 Ambient Tempoerature (-25ºC~+40ºC   
10 Enclosure Material Stainless Steel Enclosure  

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.