• 33kv 33steps Line Automatic Voltage Regulaor
  • 33kv 33steps Line Automatic Voltage Regulaor
  • 33kv 33steps Line Automatic Voltage Regulaor
  • 33kv 33steps Line Automatic Voltage Regulaor
  • 33kv 33steps Line Automatic Voltage Regulaor

33kv 33steps Line Automatic Voltage Regulaor

Current Type: AC
Phase: Three Phase
Frequency Characteristics: High Frequency
Frequency: High Frequency
Size: Large
Transport Package: Wooden
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
SZ10
Specification
15KV/27KV/38KV, 50HZ/60HZ,
Trademark
HEMG
Origin
China
Production Capacity
10000

Product Description



33kv 33steps Line Automatic Voltage Regulaor

 

SCHEDULE (H)

TECHNICAL PARTICULARS AND GUARANTEES

VOLTAGE REGULATOR

The tender shall complete this schedule, and the particulars and guarantees will be binding on the contractor.

 

REQUIREMENTS

 

 

Unit

 

 

ITEM(1)

 

Frequency

Hz

50

Type of cooling

 

ONAN

Type of V.R ratio control.

 

TAPCON 230

Number of tapping


 

33

Regulation step range.

%

+/-10%

Oil type

 

Petro-China

PARTICULARS AND GUARANTEES

Impedance at 75ºC on principal tapping

%

8

 

Maximum flux density in core at normal voltage and frequency

 

 

 

TESLA

1.80

 

Type of core steel

 

 

Silicon Steel, 30Q130

 

Winding type

 

 

Copper winding

Short circuit current

KA

4.2

Type of paper insulation on conductors

 

Electrical insulation paper

No load losses at normal ratio and 50 Hz

KW

10

Load losses at CMR, 75ºC at normal ratio

KW

58

R.M.S. Exciting current at normal voltage on principal tap

Amps

 

-R.M.S Fundamental current

Amps

0.559

-R.M.S 3rd harmonic current

Amps

0.052

-R.M.S 5th harmonic current

Amps

0.12

-R.M.S 7th harmonic current

Amps

0.062

Temperature rise of windings at CMR above specified design ambient temp.

ºC

55

Temperature rise of top oil at CMR above specified design ambient

ºC

50

Temperature rise of core at CMR and rated voltage

ºC

70

Min duration at 40°C of over loading of rating 133%

In min

120

Min duration at 40°C of over loading of rating 150%

In min

100

Impulse withstand voltage of VR

kV

 

Phase connections

 

 

(I) 1.2 /50 Microsecond full wave

kV(peak)

170

(II) 1.2 /50 Microsecond chopped wave

kV (peak)

187

Total oil required

Liters

6180

Weight of complete VR (including oil)

Kg

23500

M.V. BUSHING INSULATORS

 

 

Make

 

 

 

 

PUKO

Type

 

BW-40/630-4

Voltage rating

KV

40

Current rating

Amps

630

Length of insulator(Overall)

mm.

875

Weight of insulator

Kg

18

Total creepage distance of bushing

mm

1256

Protected creepage distance of bushing

mm.

485

Dry withstand power frequency voltage

KV

95

Routine power frequency test voltage  (1 minute)

(A) Positive

(B) Negative

KV

 

 

95

95

Wet withstand power Frequency voltage

KV

80

Maximum diameter of bushing when passing through tank top

mm.

155

Penetration of bushing into tank measured from bottom of fixing flange

mm.

210

Overall dimensions of complete VR:-

mm

4900*3800*3800

Manufacturer name and place

 

HEMG

Testing Authority name and Place

 

 

HEMG
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now