Bitmap General Specifications and Guarantee Schedule for outdoor silieone rubber termination for 36/66 kv .Single Core XLPE insulated Power Cable with round stranded Copper Conductor 1x630mm2.CU/XLPE/CU(wires+tapes) screen /HDPE sheath |
No |
Description |
Unit |
PETE requirements |
Offered data |
1 |
Name & country of Manufacturer |
|
|
HEMG |
2 |
Country of Origin |
|
|
China |
3 |
Outdoor termination type |
|
Outdoor silicone rubber terminations |
Outdoor silicone rubber terminations |
4 |
Outdoor termination designation |
|
|
Prefabricated |
5 |
Standards |
|
Cenelee ho 628/629…iec60..332..502..vde..din |
IEC60840 |
6 |
Climatic Design |
c |
(-10)to(55) |
(-10)to(55) |
7 |
Class and form of Conductor |
|
Class 2 rounded stranded &compacted conductor |
Class 2 rounded stranded &compacted |
8 |
Material of Conductor |
|
Copper |
Copper |
9 |
Rated voltage |
kv |
36/66 |
36/66 |
9.1 |
Termination suitable to be used with following cables: |
|
|
Yes |
Conductor: |
|
|
|
- Cross section |
mm² |
1x630 |
1x630 |
- diameter |
mm |
From 29.5 to 31.5 |
From 29.5 to 31.5 |
Conductor Screen: |
|
|
|
- Material |
|
Extruded semi conductive layer |
Extruded semi conductive layer |
- Thickness |
mm |
From0.85 to 1 |
From0.85 to 1 |
Insulation: |
|
|
|
- Material |
|
XLPE |
XLPE |
- Thickness |
mm |
12 |
12 |
- Diameter over insulation |
mm |
From55to58 |
From55to58 |
Insulation screen: (S.C Layer): |
|
|
|
- Material |
|
Extruded semi conductive layer |
Extruded semi conductive layer |
- Thickness |
mm |
From0.85 to 1 |
From0.85 to 1 |
- Thickness of semi-conductive swelling Tape (lapped) |
mm |
From(0.3 to .5) |
From(0.3 to .5) |
Metallic screen: |
|
|
|
- Cross section of earthing cu wires |
mm² |
120 |
120 |
- Diameter of cu wire |
mm |
1.8 |
1.8 |
- thickness of Copper Tape |
mm |
0.2 |
0.2 |
- Width of Copper Tape |
mm |
20 |
20 |
- thickness of longitude Swilling Tape |
mm |
0.2 |
0.2 |
Metallic Shield: |
|
|
|
- thickness of Comp layer al (Coated Al ) |
mm |
0.2 |
0.2 |
Outer Protective Sheath (HDPE ST7 ) |
|
|
|
- Material |
|
HDPE ST7 |
HDPE ST7 |
- Thickness of outer Sheath |
mm |
4.5 |
4.5 |
- Outer diameter of cable |
mm |
70 |
70 |
10 |
Max. service voltage |
kv |
72.5 |
72.5 |
11 |
Rated frequency |
Hz |
50 |
50 |
12 |
Power frequency with stand voltage (a) |
Kv/min |
90kv/30min |
90kv/30min |
13 |
Partial discharge level |
|
≤10 PC at 1.5 U0 (54kv) |
≤10 PC at 1.5 U0 (54kv) |
14 |
Impulse with stand voltage 10 x (+)1.2/50us |
kv |
±325 |
±325 |
15 |
Power freq. with stand voltage (b) |
Kv/min |
90kv/15min |
90kv/15min |
16 |
Load cycling test Cycle:8h heating 16h cooling |
|
According to iec 60840 on accessories |
According to iec 60840 on accessories |
Conductor temperature |
95oc-100oc |
95oc-100oc |
17 |
Thermal short circuit current : |
KA/1sec |
≥31 |
≥31 |
- 1sec/symmetrical fault with conductor temperature as for cable specification |
18 |
Resistively to mineral oil . Acids. Solvents |
|
|
Yes |
19 |
Saturated air |
|
|
Yes |
20.1 20.2 20.3 |
Water conductivity |
|
|
Yes |
Spray rate |
Salt tog test |
21 |
Humidity and congestion test |
Kv/h |
|
42.5 |
22 |
Flame resistance test |
|
IEC 332 |
IEC 332 |
23 |
Submit copies of test reports by independent laboratory |
|
Should be submitted |
Yes |
24 |
Components ayers and materials of termination and their properties: |
|
|
Yes |
24.1 |
Lug |
mm² |
Conductor 630 mm²CU |
Conductor 630 mm²CU |
24.2 |
Electrical stress control system : |
|
|
|
- indicate shrink ratio properties : |
mm |
5-8mm |
Design (shape ) |
|
Cone |
- length |
mm |
1000 |
-stress grading ( plot ) |
|
Supplied with products |
24.3 |
Insulation: |
|
|
|
24.4 |
Leakage current insulation system : |
|
|
Number of sheds(skirts):15 pcs.;Diameter of sheds:210mm;Total extended creepage distance: more than 2250 |
Number of sheds(skirts) |
|
Diameter of sheds |
mm |
Total extended creepage distance |
mm |
24.5 |
Shield. metal continuity CU screen wires Coated Aluminium tape |
mm² |
Cross section 120 |
Cross section 120 |
24.6 |
- outer sheath (outer cover ) |
|
-indicate shrink ratio |
50% |
24.7 |
Submit detailed information and documentation about the components layers and materials of termination and their electrical &non-electrical properties |
|
Provide separately |
Yes |
24.8 |
Dimensions of termination after completion: |
|
|
Diameters:220mm;overall length:1500mm |
-Diameters |
mm |
- overall length |
mm |
24.9 |
Printed on tubes |
|
Mandatory according to condition book |
Yes |
24.1 |
The applicable range of termination (cross section of conductor) |
mm² |
The wide range is preferred |
240-2000 |
25 |
Submit kit contents of termination |
|
Complete list of kit contents with description |
Yes |
26 |
Submit installation instruction |
|
Provide separately |
Yes |
27 |
Submit dimension drawing |
|
Provide separately |
Yes |
28 |
Shelf life |
year |
|
15 |
29 |
Submit quality assurance certificates (ISO accreditation) |
|
More certificates are preferable (i.e 9001.14001 etc.) |
Yes |
30 |
Submit reference list |
|
Provide separately |
Yes |
31 |
Total weight of termination kit |
kg |
|
25 |
32 |
Time of execution of one termination |
minute |
|
480 |
33 |
Include any special tools for execution of the termination (if required) with detailed description of tools (with photo/drawings) |
|
optional |
None |
34 |
Total number of required termination |
Qty |
50 |
50 |
|
No |
Description |
Unit |
Requirements |
Offered data |
1 |
Name & country of Manufacturer |
|
|
HEMG |
2 |
Country of Origin |
|
|
China |
3 |
Joint type |
|
Silicon rubber cable joint |
Silicon rubber cable joint |
4 |
Joint designation |
|
|
Prefabricated |
5 |
Standards |
|
Cenelee HO 628/629… IEC 60.332.502.. vde..din |
IEC60840 |
6 |
Climatic Design |
oc |
(-10)to(55) |
(-10)to(55) |
7 |
Class and form of Conductor |
|
Class 2 rounded stranded &compacted conductor |
Class 2 rounded stranded &compacted |
8 |
Material of Conductor |
|
copper |
copper |
9 |
Rated voltage |
kv |
36/66 |
36/66 |
9.1 |
Termination suitable to be used with following cables: |
|
|
Yes |
Conductor: |
|
|
|
- Cross section |
mm² |
1x630 |
1x630 |
- diameter |
mm |
From29.5to31.5 |
From29.5to31.5 |
Conductor Screen: |
|
|
|
- Material |
|
Extruded semi conductive layer |
Extruded semi conductive layer |
- Thickness |
mm |
From 0.85 to1 |
From 0.85 to1 |
Insulation: |
|
|
|
- Material |
|
XLPE |
XLPE |
- Thickness |
mm |
12 |
12 |
- Diameter over insulation |
mm |
From55 to58 |
From55 to58 |
Insulation Screen: (S.C Layer): |
|
|
|
- Material |
|
Extruded semi conductive layer |
Extruded semi conductive layer |
- Thickness |
mm |
From 0.85 to 1 |
From 0.85 to 1 |
- Thickness of semi-conductive swelling Tape (lapped) |
mm |
From(0.3 to0.5) |
From(0.3 to0.5) |
Metallic Screen: |
|
|
|
- Cross section of earthing cu wires |
mm² |
120 |
120 |
- Diameter of cu wire |
mm |
1.8 |
1.8 |
- thickness of Copper Tape |
mm |
0.2 |
0.2 |
- Width of Copper Tape |
mm |
20 |
20 |
- thickness of longitude Swilling Tape |
mm |
0.2 |
0.2 |
metallic Shield: |
|
|
|
- thickness of Comp layer al (Coated Al ) |
mm |
0.2 |
0.2 |
Outer Protective Sheath (HDPE ST7 ) |
|
|
|
- Material |
|
HDPE ST7 |
HDPE ST7 |
- Thickness of outer Sheath |
mm |
4.5 |
4.5 |
- Outer diameter of cable |
mm |
70 |
70 |
10 |
Max .service voltage |
Kv |
72.5 |
72.5 |
11 |
Rated frequency |
Hz |
50 |
50 |
12 |
Power frequency |
Kv/min |
90kv/30min |
90kv/30min |
13 |
Partial discharge level |
|
≤10PC at 1.5U0(54kv) |
≤10PC at 1.5U0(54kv) |
14 |
Impulse withstand voltage 10x(+)1.2/50us |
kv |
±325 |
±325 |
15 |
Power freq.with stand voltage (b) |
Kv/min |
90kv/15min |
90kv/15min |
16 |
Load cycling test cycle:5 h heating 3 h cooling |
|
3 cycles |
3 cycles |
-conductor temperature |
90ºC+10ºC |
90ºC+10ºC |
17 |
Thermal short circuit current : |
KA/1sec |
≥31 |
≥31 |
- 1sec/symmetrical fault with conductor temperature as for cable specification |
18 |
Resistively to mineral oil . acids. solvents |
|
|
Yes |
19 |
Humidity and congestion test |
Kv/h |
|
41.8 |
20 |
Flame resistance test |
|
IEC 332 |
IEC 332 |
21 |
Submit copies of test reports by independent laboratory |
|
Should be submitted |
Yes |
22 |
Components layers and materials of joint and their properties: |
|
|
|
22.1 |
Conductor connector |
|
Bolted or mechanical ( pressure ) |
Pressure |
22.2 |
Electrical stress control system : |
|
|
Design (shape ): Stress cone;length:610mm. |
- indicate shrink ratio properties : |
mm |
8-12mm |
- Design (shape ) |
|
Cylindrical |
- length |
mm |
610 |
-stress grading ( plot ) |
|
Supplied with products |
22.3 |
Insulation: |
mm |
|
|
Screening |
Thickness:0.5 |
22.4 |
Shield. Metal continuity CU screen wires coated Aluminium tape |
mm² |
Cross section 120 - 130 mm² |
Cross section 120 - 130 mm² |
22.5 |
Outer sheath ( outer cover ) |
|
Heat shrink tube with adhesive (in one picce ) (heat melt adhesive) |
50% |
Indicate shrink ratio |
22.6 |
Submit detailed information and documentation about the components layers and materials of termination and their electrical &non-electrical properties |
|
Provide separately |
Yes |
22.7 |
Dimensions of termination after completion: |
|
|
Diameters:200mm;overall length:1500mm |
-Diameters |
mm |
- overall length |
mm |
22.8 |
- printed on all heat shrink tubes |
|
Mandatory according to condition book |
Yes |
22.9 |
The applicable range of joint ( cross section of conductor ) |
mm² |
The wide range is preferred |
240-2000 |
23 |
Submit kit contents of joint |
|
Complete list of kit contents with description |
Yes |
24 |
Submit installation instruction |
|
Provide separately |
Yes |
25 |
Submit dimensions drawing |
|
Provide separately |
Yes |
26 |
Shelf life |
Year |
|
15 |
27 |
Submit test reports of all materials of joint kit |
|
Provide separately |
Yes |
28 |
Submit quality assurance certificate ( ISO accreditation ) |
|
More certificates are preferable ( i.e 9001 . 14001 ete ) |
Yes |
29 |
Submit reference list |
|
Provide separately |
Yes |
30 |
Total weight of joint box |
Kg |
|
85 |
31 |
Time of execution of one joint |
Minute |
|
500 |
32 |
Include any special tools for execution of the joint ( if required) with detailed description of tools ( with photo/drawings) |
|
Optional |
None |
33 |
Total joints |
Qty |
200 |
200 |