720V 50Hz/60Hz Indoor Lmz1 Low Voltage Busbar Type Metering Current Transformer

Application: Electronic, Instrument
Type: Current Transformer
Phase: Single
Operation Condition: Indoor
Usage: Protection, Measurement
Winding Form: Single Layer & Tightly Wound Type
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
LMZ1
Insulating Medium
Epoxy Resin
Installation
Busbar Type
Transport Package
Carton with Wooden
Specification
720V 50A-1000A/5A(1A)
Trademark
HEMG
Origin
China
Production Capacity
1000000

Product Description

 720V 50Hz/60Hz Indoor Lmz1 Low Voltage Busbar Type Metering Current Transformer

 
 
CURRENT TRANSFORMER  0.72 Kv, TYPE TOROIDAL,  60 Hz , 50/5 A, Class 0.2. 5VA
 
ÍTEM SAP: 270919
 
          Ratio  (A) 50/5
Voltage of operatión (kV) 0.23/0.38/0.44
 
 
ÍTEM CHARACTERÍSTICS  UNIT  REQUIRED  GUARANTEED
1 General Characterístics       
1.1 COUNTRY ------ Indicate CHINA
1.2 MANUFACTURER ------ Indicate HEMG
1.3 MODEL ------ Indicate
 
LMZ1-0.5A
1.4 STANDARD ------ IEC 61869-1 (2007);
IEC 61869-2 (2012)
IEC 61869-1 (2007);
IEC 61869-2 (2012)
1.5 APPLICATION ------ MEASURE MEASURE
2 Nominal data and characterístics      
2.1 FREQUENCY Hz 60 60
2.2 TYPE ------ TOROIDAL TOROIDAL
2.3 MOUNTING ------ INDOOR INDOOR
2.4 INSULATION LEVEL      
  MAX. VOLTAGE OF OPERATION kV 0.72 0.72
  VOLTAGE WITH INDUSTRIAL FREQUENCY, 1 MINUTE SECONDARY     kV 3 3
2.5 CURRENTS      
  Nominal secondary current (Isn) A 5 5
  Nominal primary current (Ipn) A 50 50
  Nominal thermal current of shortcircuit  (Ith),   IEC 61869-2 A 60 Ipn 60 Ipn
  Nominal dynamic current (Idyn)  IEC 61869-2 A 2.5 Ith 2.5 Ith
2.6 Ratio of  transformatión A 50/5 50/5
2.7 Power VA 5 5
2.8 Precision class cl 0.2 0.2
2.9 Class thermal of insulation  (IEC 60085)   E E
2.10 Factor of security   5 5
2.11 Guarantee the precisión class in the range     from 25%Isn  to 100% Isn from 25%Isn  to 100% Isn
3 Accesories      
3.1 Fixation to the base ------ yes  yes 
3.2 Fixation to rail DIN ------ yes /
3.3 Dimensions                  
  Internal Diameter mm  Indicate 30
  External diameter mm Indicate 92
  Height mm indicate 117
3.4 Metallic nameplate with  technicall characterístics and scheme of connection ------ yes yes
3.5  Sealable terminals, with holes of sufficient diameter to pass through the thread of the seal ------ yes yes
3.6  Grounding Terminals                       yes                  yes
3.7   Presents the Certificate and Protocol of type tests of compliance of the standard IEC 61869-2   Yes Yes
 
 
 
 
 
CURRENT TRANSFORMER  0.72 Kv, TYPE TOROIDAL,  60 Hz , 100/5 A, Class 0.2. 5VA
 
 
ÍTEM SAP: 270911
 
          Ratio  (A) 100/5
Voltage of operatión (kV) 0.23/0.38/0.44
 
 
ÍTEM CHARACTERÍSTICS  UNIT  REQUIRED  GUARANTEED
1 General Characterístics       
1.1 COUNTRY ------ Indicate CHINA
1.2 MANUFACTURER ------ Indicate HEMG
1.3 MODEL ------ Indicate
 
LMZ1-0.5A
1.4 STANDARD
 
------ IEC 61869-1 (2007);
IEC 61869-2 (2012)
IEC 61869-1 (2007);
IEC 61869-2 (2012)
1.5 APPLICATION ------ MEASURE MEASURE
2 Nominal data and characterístics      
2.1 FREQUENCY Hz 60 60
2.2 TYPE ------ TOROIDAL TOROIDAL
2.3 MOUNTING ------ INDOOR INDOOR
2.4 INSULATION LEVEL      
  MAX. VOLTAGE OF OPERATION kV 0.72 0.72
  VOLTAGE WITH INDUSTRIAL FREQUENCY, 1 MINUTE SECONDARY     kV 3 3
2.5 CURRENTS      
  Nominal secondary current (Isn) A 5 5
  Nominal primary current (Ipn) A 100 100
  Nominal thermal current of shortcircuit  (Ith),   IEC 61869-2 A 60 Ipn 60 Ipn
  Nominal dynamic current (Idyn)  IEC 61869-2 A 2.5 Ith 2.5 Ith
2.6 Ratio of  transformatión A 100/5 100/5
2.7 Power VA 5 5
2.8 Precision class cl 0.2 0.2
2.9 Class thermal of insulation  (IEC 60085)   E E
2.10 Factor of security   5 5
2.11 Guarantee the precisión class in the range     from 25%Isn  to 100% Isn from 25%Isn  to 100% Isn
3 Accesories      
3.1 Fixation to the base ------ yes  yes 
3.2 Fixation to rail DIN ------ yes /
3.3 Dimensions                  
  Internal Diameter mm  Indicate 30
  External diameter mm Indicate 92
  Height mm indicate 117
3.4 Metallic nameplate with  technicall characterístics and scheme of connection ------ yes yes
3.5  Sealable terminals, with holes of sufficient diameter to pass through the thread of the seal ------ yes yes
3.6  Grounding Terminals                       yes                  yes
3.7   Presents the Certificate and Protocol of type tests of compliance of the standard IEC 61869-2   Yes Yes
 
 
 
 
CURRENT TRANSFORMER  0.72 Kv, TYPE TOROIDAL,  60 Hz , 150/5 A, Class 0.2. 5VA
 
 
ÍTEM SAP: 270912
 
          Ratio  (A) 150/5
Voltage of operatión (kV) 0.23/0.38/0.44
 
 
ÍTEM CHARACTERÍSTICS  UNIT  REQUIRED  GUARANTEED
1 General Characterístics       
1.1 COUNTRY ------ Indicate CHINA
1.2 MANUFACTURER ------ Indicate HEMG
1.3 MODEL ------ Indicate
 
LMZ1-0.5A
1.4 STANDARD
 
------ IEC 61869-1 (2007);
IEC 61869-2 (2012)
IEC 61869-1 (2007);
IEC 61869-2 (2012)
1.5 APPLICATION ------ MEASURE MEASURE
2 Nominal data and characterístics      
2.1 FREQUENCY Hz 60 60
2.2 TYPE ------ TOROIDAL TOROIDAL
2.3 MOUNTING
 
------ INDOOR INDOOR
2.4 INSULATION LEVEL      
  MAX. VOLTAGE OF OPERATION kV 0.72 0.72
  VOLTAGE WITH INDUSTRIAL FREQUENCY, 1 MINUTE SECONDARY     kV 3 3
2.5 CURRENTS      
  Nominal secondary current (Isn) A 5 5
  Nominal primary current (Ipn) A 150 150
  Nominal thermal current of shortcircuit  (Ith),   IEC 61869-2 A 60 Ipn 60 Ipn
  Nominal dynamic current (Idyn)  IEC 61869-2 A 2.5 Ith 2.5 Ith
2.6 Ratio of  transformatión A 150/5 150/5
2.7 Power VA 5 5
2.8 Precision class cl 0.2 0.2
2.9 Class thermal of insulation  (IEC 60085)   E E
2.10 Factor of security   5 5
2.11 Guarantee the precisión class in the range     from 25%Isn  to 100% Isn from 25%Isn  to 100% Isn
3 Accesories      
3.1 Fixation to the base ------ yes  yes 
3.2 Fixation to rail DIN
 
------ yes /
3.3 Dimensions                  
  Internal Diameter mm  Indicate 30
  External diameter mm Indicate 92
  Height mm indicate 117
3.4 Metallic nameplate with  technicall characterístics and scheme of connection ------ yes yes
3.5  Sealable terminals, with holes of sufficient diameter to pass through the thread of the seal ------ yes yes
3.6  Grounding Terminals                       yes                  yes
3.7   Presents the Certificate and Protocol of type tests of compliance of the standard IEC 61869-2   Yes Yes
 
 
 
 
 
CURRENT TRANSFORMER  0.72 Kv, TYPE TOROIDAL,  60 Hz , 200/5 A, Class 0.2. 5VA
 
 
ÍTEM SAP: 270913
 
          Ratio  (A) 200/5
Voltage of operatión (kV) 0.23/0.38/0.44
 
 
ÍTEM CHARACTERÍSTICS  UNIT  REQUIRED  GUARANTEED
1 General Characterístics       
1.1 COUNTRY ------ Indicate CHINA
1.2 MANUFACTURER ------ Indicate HEMG
1.3 MODEL ------ Indicate
 
LMZ1-0.5A
1.4 STANDARD
 
------ IEC 61869-1 (2007);
IEC 61869-2 (2012)
IEC 61869-1 (2007);
IEC 61869-2 (2012)
1.5 APPLICATION ------ MEASURE MEASURE
2 Nominal data and characterístics      
2.1 FREQUENCY Hz 60 60
2.2 TYPE ------ TOROIDAL TOROIDAL
2.3 MOUNTING ------ INDOOR INDOOR
2.4 INSULATION LEVEL      
  MAX. VOLTAGE OF OPERATION kV 0.72 0.72
  VOLTAGE WITH INDUSTRIAL FREQUENCY, 1 MINUTE SECONDARY     kV 3 3
2.5 CURRENTS      
  Nominal secondary current (Isn) A 5 5
  Nominal primary current (Ipn) A 200 200
  Nominal thermal current of shortcircuit  (Ith),   IEC 61869-2 A 60 Ipn 60 Ipn
  Nominal dynamic current (Idyn)  IEC 61869-2 A 2.5 Ith 2.5 Ith
2.6 Ratio of  transformatión A 200/5 200/5
2.7 Power VA 5 5
2.8 Precision class cl 0.2 0.2
2.9 Class thermal of insulation  (IEC 60085)   E E
2.10 Factor of security   5 5
2.11 Guarantee the precisión class in the range     from 25%Isn  to 100% Isn from 25%Isn  to 100% Isn
3 Accesories      
3.1 Fixation to the base ------ yes  yes 
3.2 Fixation to rail DIN ------ yes /
3.3 Dimensions                  
  Internal Diameter mm  Indicate 30
  External diameter mm Indicate 92
  Height mm indicate 117
3.4 Metallic nameplate with  technicall characterístics and scheme of connection ------ yes yes
3.5  Sealable terminals, with holes of sufficient diameter to pass through the thread of the seal ------ yes yes
3.6  Grounding Terminals                       yes                  yes
3.7   Presents the Certificate and Protocol of type tests of compliance of the standard IEC 61869-2   Yes Yes
 
 
 
 
 
 
CURRENT TRANSFORMER  0.72 Kv, TYPE TOROIDAL,  60 Hz , 250/5 A, Class 0.2. 5VA
 
 
 
ÍTEM SAP: 270914
 
 
          Ratio  (A) 250/5
Voltage of operatión (kV) 0.23/0.38/0.44
   
 
 
ÍTEM CHARACTERÍSTICS 
 
UNIT  REQUIRED  GUARANTEED
1 General Characterístics       
1.1 COUNTRY ------ Indicate CHINA
1.2 MANUFACTURER ------ Indicate HEMG
1.3 MODEL ------ Indicate
 
LMZ1-0.5A
1.4 STANDARD
 
------ IEC 61869-1 (2007);
IEC 61869-2 (2012)
IEC 61869-1 (2007);
IEC 61869-2 (2012)
1.5 APPLICATION ------ MEASURE MEASURE
2 Nominal data and characterístics      
2.1 FREQUENCY Hz 60 60
2.2 TYPE ------ TOROIDAL TOROIDAL
2.3 MOUNTING ------ INDOOR INDOOR
2.4 INSULATION LEVEL      
  MAX. VOLTAGE OF OPERATION kV 0.72 0.72
  VOLTAGE WITH INDUSTRIAL FREQUENCY, 1 MINUTE SECONDARY     kV 3 3
2.5 CURRENTS      
  Nominal secondary current (Isn) A 5 5
  Nominal primary current (Ipn) A 250 250
  Nominal thermal current of shortcircuit  (Ith),   IEC 61869-
2
A 60 Ipn 60 Ipn
  Nominal dynamic current (Idyn)  IEC 61869-2 A 2.5 Ith 2.5 Ith
2.6 Ratio of  transformatión A 250/5 250/5
2.7 Power VA 5 5
2.8 Precision class cl 0.2 0.2
2.9 Class thermal of insulation  (IEC 60085)   E E
2.10 Factor of security   5 5
2.11 Guarantee the precisión class in the range     from 25%Isn  to 100% Isn from 25%Isn  to 100% Isn
3 Accesories      
3.1 Fixation to the base ------ yes  yes 
3.2 Fixation to rail DIN ------ yes /
3.3 Dimensions                  
  Internal Diameter mm  Indicate 35
  External diameter mm Indicate 97
  Height mm indicate 125
3.4 Metallic nameplate with  technicall characterístics and scheme of connection ------ yes yes
3.5  Sealable terminals, with holes of sufficient diameter to pass through the thread of the seal ------ yes yes
3.6  Grounding Terminals  
 
                    yes                  yes
3.7   Presents the Certificate and Protocol of type tests of compliance of the standard IEC 61869-2   Yes Yes
 
CURRENT TRANSFORMER  0.72 Kv, TYPE TOROIDAL,  60 Hz , 300/5 A, Class 0.2. 5VA
 
 
ÍTEM SAP: 270915
 
          Ratio  (A) 300/5
Voltage of operatión (kV) 0.23/0.38/0.44
 
 
ÍTEM CHARACTERÍSTICS  UNIT  REQUIRED  GUARANTEED
1 General Characterístics       
1.1 COUNTRY ------ Indicate CHINA
1.2 MANUFACTURER ------ Indicate HEMG
1.3 MODEL ------ Indicate
 
LMZ1-0.5A
1.4 STANDARD
 
------ IEC 61869-1 (2007);
IEC 61869-2 (2012)
IEC 61869-1 (2007);
IEC 61869-2 (2012)
1.5 APPLICATION ------ MEASURE MEASURE
2 Nominal data and characterístics      
2.1 FREQUENCY Hz 60 60
2.2 TYPE ------ TOROIDAL TOROIDAL
2.3 MOUNTING ------ INDOOR INDOOR
2.4 INSULATION LEVEL      
  MAX. VOLTAGE OF OPERATION kV 0.72 0.72
  VOLTAGE WITH INDUSTRIAL FREQUENCY, 1 MINUTE SECONDARY     kV 3 3
2.5 CURRENTS      
  Nominal secondary current (Isn) A 5 5
  Nominal primary current (Ipn) A                    300 300
  Nominal thermal current of shortcircuit  (Ith),   IEC 61869-2 A 60 Ipn 60 Ipn
  Nominal dynamic current (Idyn)  IEC 61869-2 A 2.5 Ith 2.5 Ith
2.6 Ratio of  transformatión A 300/5 300/5
2.7 Power VA 5 5
2.8 Precision class cl 0.2 0.2
2.9 Class thermal of insulation  (IEC 60085)   E E
2.10 Factor of security   5 5
2.11 Guarantee the precisión class in the range     from 25%Isn  to 100% Isn from 25%Isn  to 100% Isn
3 Accesories      
3.1 Fixation to the base ------ yes  yes 
3.2 Fixation to rail DIN ------ yes /
3.3 Dimensions                  
  Internal Diameter mm  Indicate 35
  External diameter mm Indicate 97
  Height mm indicate 125
3.4 Metallic nameplate with  technicall characterístics and scheme of connection ------ yes yes
3.5  Sealable terminals, with holes of sufficient diameter to pass through the thread of the seal ------ yes yes
3.6  Grounding Terminals                       yes                  yes
3.7   Presents the Certificate and Protocol of type tests of compliance of the standard IEC 61869-2   Yes Yes
 
 
 
 
 
 
 
 
CURRENT TRANSFORMER  0.72 Kv, TYPE TOROIDAL,  60 Hz , 350/5 A, Class 0.2. 5VA
 
 
 
ÍTEM SAP: 270916
 
 
          Ratio  (A) 350/5
Voltage of operatión (kV) 0.23/0.38/0.44
   
 
 
ÍTEM CHARACTERÍSTICS  UNIT  REQUIRED  GUARANTEED
1 General Characterístics       
1.1 COUNTRY ------ Indicate CHINA
1.2 MANUFACTURER ------ I
ndicate
HEMG
1.3 MODEL ------ Indicate
 
LMZ1-0.5A
1.4 STANDARD
 
------ IEC 61869-1 (2007);
IEC 61869-2 (2012)
IEC 61869-1 (2007);
IEC 61869-2 (2012)
1.5 APPLICATION ------ MEASURE MEASURE
2 Nominal data and characterístics      
2.1 FREQUENCY Hz 60 60
2.2 TYPE ------ TOROIDAL TOROIDAL
2.3 MOUNTING ------ INDOOR INDOOR
2.4 INSULATION LEVEL      
  MAX. VOLTAGE OF OPERATION kV 0.72 0.72
  VOLTAGE WITH INDUSTRIAL FREQUENCY, 1 MINUTE SECONDARY     kV 3 3
2.5 CURRENTS      
  Nominal secondary current (Isn) A 5 5
  Nominal primary current (Ipn) A 350 350
  Nominal thermal current of shortcircuit  (Ith),   IEC 61869-2 A 60 Ipn 60 Ipn
  Nominal dynamic current (Idyn)  IEC 61869-2 A 2.5 Ith 2.5 Ith
2.6 Ratio of  transformatión A 350/5 350/5
2.7 Power VA 5 5
2.8 Precision class cl 0.2 0.2
2.9 Class thermal of insulation  (IEC 60085)   E E
2.10 Factor of security   5 5
2.11 Guarantee the precisión class in the range     from 25%Isn  to 100% Isn from 25%Isn  to 100% Isn
3 Accesories      
3.1 Fixation to the base ------ yes  yes 
3.2 Fixation to rail DIN ------ yes /
3.3 Dimensions                  
  Internal Diameter mm  Indicate 35
  External diameter mm Indicate 97
  Height mm indicate 125
3.4 Metallic nameplate with  technicall characterístics and scheme of connection ------ yes yes
3.5  Sealable terminals, with holes of sufficient diameter to pass through the thread of the seal ------ yes yes
3.6  Grounding Terminals                       yes                  yes
3.7   Presents the Certificate and Protocol of type tests of compliance of the standard IEC 61869-2   Yes Yes
:300A
 
 
 
CURRENT TRANSFORMER  0.72 Kv, TYPE TOROIDAL,  60 Hz , 400/5 A, Class 0.2. 5VA
 
 
ÍTEM SAP: 270917
 
          Ratio  (A) 400/5
Voltage of operatión (kV) 0.23/0.38/0.44
 
 
ÍTEM CHARACTERÍSTICS  UNIT  REQUIRED  GUARANTEED
1 General Characterístics       
1.1 COUNTRY ------ Indicate CHINA
1.2 MANUFACTURER ------ Indicate HEMG
1.3 MODEL ------ Indicate
 
LMZ1-0.5A
1.4 STANDARD
 
------ IEC 61869-1 (2007);
IEC 61869-2 (2012)
IEC 61869-1 (2007);
IEC 61869-2 (2012)
1.5 APPLICATION ------ MEASURE MEASURE
2 Nominal data and characterístics      
2.1 FREQUENCY Hz 60 60
2.2 TYPE ------ TOROIDAL TOROIDAL
2.3 MOUNTING ------ INDOOR INDOOR
2.4 INSULATION LEVEL      
  MAX. VOLTAGE OF OPERATION kV 0.72 0.72
  VOLTAGE WITH INDUSTRIAL FREQUENCY, 1 MINUTE SECONDARY     kV 3 3
2.5 CURRENTS      
  Nominal secondary current (Isn) A 5 5
  Nominal primary current (Ipn) A 400 400
  Nominal thermal current of shortcircuit  (Ith),   IEC 61869-2 A 60 Ipn 60 Ipn
  Nominal dynamic current (Idyn)  IEC 61869-2 A 2.5 Ith 2.5 Ith
2.6 Ratio of  transformatión A 400/5 400/5
2.7 Power VA 5 5
2.8 Precision class cl 0.2 0.2
2.9 Class thermal of insulation  (IEC 60085)   E E
2.10 Factor of security   5 5
2.11 Guarantee the precisión class in the range     from 25%Isn  to 100% Isn from 25%Isn  to 100% Isn
3 Accesories      
3.1 Fixation to the base ------ yes  yes 
3.2 Fixation to rail DIN ------ yes /
3.3 Dimensions                  
  Internal Diameter mm  Indicate 45
  External diameter mm Indicate 97
  Height mm indicate 125
3.4 Metallic nameplate with  technicall characterístics and scheme of connection ------ yes yes
3.5  Sealable terminals, with holes of
sufficient diameter to pass through the thread of the seal
------ yes yes
3.6  Grounding Terminals                       yes                  yes
3.7   Presents the Certificate and Protocol of type tests of compliance of the standard IEC 61869-2   Yes Yes
 
 
 
 
 
 
CURRENT TRANSFORMER  0.72 Kv, TYPE TOROIDAL,  60 Hz , 450/5 A, Class 0.2. 5VA
 
 
ÍTEM SAP: 270918
 
          Ratio  (A) 450/5
Voltage of operatión (kV) 0.23/0.38/0.44
 
 
ÍTEM CHARACTERÍSTICS  UNIT  REQUIRED  GUARANTEED
1 General Characterístics       
1.1 COUNTRY ------ Indicate CHINA
1.2 MANUFACTURER ------ Indicate HEMG
1.3 MODEL ------ Indicate
 
LMZ1-0.5A
1.4 STANDARD
 
------ IEC 61869-1 (2007);
IEC 61869-2 (2012)
IEC 61869-1 (2007);
IEC 61869-2 (2012)
1.5 APPLICATION ------ MEASURE MEASURE
2 Nominal data and characterístics      
2.1 FREQUENCY Hz 60 60
2.2 TYPE ------ TOROIDAL TOROIDAL
2.3 MOUNTING ------ INDOOR INDOOR
2.4 INSULATION LEVEL      
  MAX. VOLTAGE OF OPERATION kV 0.72 0.72
  VOLTAGE WITH INDUSTRIAL FREQUENCY, 1 MINUTE SECONDARY     kV 3 3
2.5 CURRENTS      
  Nominal secondary current (Isn) A 5 5
  Nominal primary current (Ipn) A 450 450
  Nominal thermal current of shortcircuit  (Ith),   IEC 61869-2 A 60 Ipn 60 Ipn
  Nominal dynamic current (Idyn)  IEC 61869-2 A 2.5 Ith 2.5 Ith
2.6 Ratio of  transformatión A 450/5 450/5
2.7 Power VA 5 5
2.8 Precision class cl 0.2 0.2
2.9 Class thermal of insulation  (IEC 60085)   E E
2.10 Factor of security   5 5
2.11 Guarantee the precisión class in the range     from 25%Isn  to 100% Isn from 25%Isn  to 100% Isn
3 Accesories      
3.1 Fixation to the base ------ yes  yes 
3.2 Fixation to rail DIN ------ yes /
3.3 Dimensions                  
  Internal Diameter mm  Indicate 45
  External diameter mm Indicate 97
  Height mm indicate 125
3.4 Metallic nameplate with  technicall characterístics and scheme of connection ------ yes yes
3.5  Sealable terminals, with holes of sufficient diameter to pass through the thread of the seal ------ yes yes
3.6  Grounding Terminals                       yes                  yes
3.7   Presents the Certificate and Protocol of type tests of compliance of the standard IEC 61869-2   Yes Yes
 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now