• 15kv/24kv/38kv Outdoor Epoxy Resin Current Transformer
  • 15kv/24kv/38kv Outdoor Epoxy Resin Current Transformer
  • 15kv/24kv/38kv Outdoor Epoxy Resin Current Transformer
  • 15kv/24kv/38kv Outdoor Epoxy Resin Current Transformer
  • 15kv/24kv/38kv Outdoor Epoxy Resin Current Transformer

15kv/24kv/38kv Outdoor Epoxy Resin Current Transformer

Application: Instrument
Type: Current Transformer
Phase: Single
Operation Condition: Outdoor
Usage: Protection, Measurement
Winding Form: Multilayer Honeycomb Type
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
LZW-24
Insulating Medium
Epoxy Resin
Installation
Extension Type
Magnetic Circuit Structure
Combined Type
Transport Package
Wooden Case
Specification
24KV, 50HZ/60HZ, 800-50A/5A
Trademark
HEMG
Origin
China
Production Capacity
50000

Product Description

15kv/24kv/38kv Outdoor Epoxy Resin Current Transformer

24kV CURRENT TRANSFORMERS FOR POLLUTED AREAS            
No.

Description

Required Offered
  1.  
Manufacturer
To be specified HEMG
  1.  
Country of origin
To be specified China
  1.  
Manufacturer's reference/cat. Number To be specified LZW-24
  1.  
Standards of quality management ISO 9001 ISO 9001
(check attachment)
  1.  
Applicable standards IEC 60185, IEC 60044-1 or equivalent IEC 60185, IEC 60044-1 or equivalent
  1.  
Type Single phase, outdoor, epoxy cast resin or polymer (silicone rubber or silicone alloy) insulator capable of operating under polluted conditions such as coastal areas, hoarfrost, industrial contamination, UV radiation, etc., as well as humid tropical climat Single phase, outdoor, epoxy cast resin ,
insulator capable of operating under polluted conditions such as coastal areas, hoarfrost, industrial contamination, UV radiation, etc., as well as humid tropical climate
  1.  
Rated maximum system voltage [kV] 24 24
  1.  
Ratio transformers (Double-ratio: Ir11-Ir12/Ir2) [A]
 
5-10/5
10-20/5
15-30/5
20-40/5
25-50/5
30-60/5
50-100/5
75-150/5
100-200/5
150-300/5
200-400/5
250-500/5
300-600/5
400-800/5
5-10/5
10-20/5
15-30/5
20-40/5
25-50/5
30-60/5
50-100/5
75-150/5
100-200/5
150-300/5
200-400/5
250-500/5
300-600/5
400-800/5
  1.  
Number of secondary winding 1 1
  1.  
Accuracy class 0.5 0.5

11

Rated continuous thermal current

1.2x(Ir11-Ir12)

1.2x(Ir11-Ir12)
  Rated burden [VA] 10 10
  1.  
Rated short-time thermal current (Ith), 1s [kA].    
CT 5-10/5A
CT 10-20/5A
CT 15-30/5A
CT 20-40/5A
CT 25-50/5A
CT 30-60/5A
CT 50-100/5A
CT 75-150/5A
CT 100-200/5A
CT 150-300/5A
CT 200-400/5A
CT 250-500/5A
CT 300-600/5A
CT 400-800/5A
0.8
1.6

2.4
3.2
4.0
4.8
8.0
12.0
16.0
24.0
25.0
25.0
25.0
25.0
0.8
1.6

2.4
3.2
4.0
4.8
8.0
12.0
16.0
24.0
25.0
25.0
25.0
25.0
  1.  
Rated dynamic current (Idyn) [kA] 2.5 x Ith 2.5 x Ith
  1.  
Rated frequency [Hz] 50 50
  1.  
Lightning impulse withstand voltage (1.2/50ms [kVp] 125 125
  1.  
Power frequency withstand voltage on primary winding, 50Hz, 1min [kVrms] 50 50
  1.  
Power frequency withstand voltage on secondary winding, 50Hz, 1min [kVrms] 2 2
  1.  
Creepage distance [mm] ³ 600 ³ 600
  1.  
Max. ambient temperature [°C] 50 50
  1.  

Max. relative humidity [%]

90 90
  1.  
Limits of temperature rise  [°C] 60 60
  1.  
Included accessories
  • 1) The MV terminals and connectors made of tinplated copper for aluminum/copper conductors up to 240sqmm.
  •  
  •  
  •  
  •  
  •  
2).The secondary wiring cover made of aluminum, stainless steel or hot dip galvanized steel; The bolts of the cover having a provision for security sealing.
.
3).The base made of aluminum, stainless steel or hot dip galvanized steel.
4)Bolts, nuts, and washers made of hot dip galvanized steel or stainless steel.
1). The MV terminals and connectors made of tin-plated copper for aluminum/copper conductors up to 240sqmm.


2).The secondary wiring cover made of pastic



3) The base made of steel


4)Bolts, nuts, and washers made of hot dip galvanized steel or stainless steel.
  1.  
Inspection and tests 1) Type tests, which have been carried out by an independent testing laboratory on the similar products, shall be submitted with the tender as follows:
  • Shorttime current test;
  • Temperaturerise test;
  • Lightning impulse test on primary winding;
  • Wet test for outdoor type transformer;
  • Determination of accuracy.

2) Routine tests, which shall be made by the manufacturer on each supplied individual product at the manufacturer's factory, shall be submitted to the Purchaser upon the goods to be delivered. These tests shall be carried out as follows:
  • Verification of terminal markings;
  • Powerfrequency withstand test on primary and secondary windings;
  • Partial discharge measurement;
  • Powerfrequency withstand test between sections;
  • Interturn overvoltage test;
  • Determination of accuracy.
-

3) Acceptance tests (sample test), which have been carried out by an independent testing laboratory on supplied typical voltage transformer, including:
  • Powerfrequency withstand tests on primary and secondary windings;
  • Determination of accuracy
1)We offer the similar type test report  LCZ-35

( because  35KV is stardared voltage  in our country ,this voltage adapt below 35kv current transformer )



2).when manufacturer  finish the producing , manufacturer will offer for buyer















3).when manufacturer  finish the producing , manufacturer will offer for buyer
 
  1.  
Catalogues/drawings   Check attachment
  1.  
Certificate of pattern approval    
  1.  
Reference lists as stipulated in the commercial requirements    



15kv/24kv/38kv Outdoor Epoxy Resin Current Transformer







 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation
Registered Capital
500 RMB
Plant Area
1001~2000 square meters